Basic functions
7.27 Pulse/direction interface
Drive functions
422
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
7.27
Pulse/direction interface
Thanks to the pulse/direction interface, in the SERVO and VECTOR control modes,
SINAMICS S120 can be used for simple positioning tasks on a controller.
●
The encoder interface of the SMC30 (connector X521) is used to connect the controller to
the CU320-2.
●
The internal encoder interface at connector X23 is used to connect the controller to the
CU310-2.
The controller enters the setpoints for the pulse/direction signals to the drive via the encoder
interface.
The specified actual speed value r0061 can then be connected as speed setpoint to the fixed
setpoint p1155 via BICO.
Note
•
More information on the Control Unit CU320-2 and the SMC30 is provided in the
SINAMICS S120 Control Units Manual.
•
More information on the Control Unit CU310-2 is provided in the SINAMICS S120 AC
Drive Manual.
Application: Speed-controlled drive
The drive is subject to speed control when operating on the controller. The clock frequency
stipulates the speed setpoint. The pulse number is entered in p0408. This is calculated from
the clock frequency of the controller and the preferred maximum motor speed. The following
formula applies:
Pulse number = (max. clock frequency · 60)/max. speed
Example: If the controller has a maximum clock frequency of 100 kHz and the motor being
used is to run at its maximum rated speed of 3000 rpm, the resulting pulse number will be
2000.
Wiring the SMC30 input signals
The input signals for the pulse/direction interface are wired via connector X521 of the
SMC30:
Table 7- 14 Wiring the SMC30
Pin
Signal name
Technical specifications
1
Pulse
–
2
M
Ground
3
Direction of rotation
–
4
M
Ground
5 ... 8
Not relevant
–
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......