S
IN
A
MICS
G1
30/G150
List
Manual (LH
2)
, 07/2
016
, A5E0326347
9A
11
4
7
3
F
un
ction dia
g
ra
ms
3.6
P
ROFIdr
ive
F
ig.
3
-41
24
51 – ZSW
1 status word in
terco
nnectio
n (p
2038
=
2)
- 2451 -
Function diagram
8
7
6
5
4
3
2
1
fp_2451_54_eng.vsd
DO: VECTOR
S120/S150/G130/G150
27.06.13 V04.08.00
PROFIdrive - ZSW1 status word interconnection (p2038 = 2)
<1> Used in telegram 20.
<2> The ZSW1 is generated using the binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...p2088[0].15)
<3> The drive object is ready to accept data.
<4> Interconnection is not disabled.
PROFIdrive sampling time
Signal sources for ZSW1 in Interface Mode VIK-NAMUR (p2038 = 2)
Signal
Meaning
ZSW1.0
ZSW1.1
ZSW1.2
ZSW1.3
ZSW1.4
ZSW1.5
ZSW1.6
ZSW1.8
ZSW1.9
ZSW1.11
ZSW1.12
ZSW1.13
ZSW1.14
ZSW1.15
ZSW1.7
ZSW1.10
1 = Ready for operation
(DC link loaded, pulses inhibited)
1 = Ready for switching on
1 = Operation enabled
(drive follows n_set)
1 = Fault present
1 = No coast down active (OFF2 inactive)
1 = No quick stop active (OFF3 inactive)
1 = Power-on inhibit active
1 = Alarm present
1 = Speed setpoint - actual value deviation within tolerance t_off
1 = Control requested
1 = f or n comparison value reached/exceeded
1 = I, M, or P limit not reached
Reserved
1 = No motor overtemperature alarm
1 = Command Data Set selection CDS bit 0
1 = Motor rotates forwards (n_act 0)
0 = Motor rotates backwards (n_act < 0)
<3>
p2080[2] = r0899.2
p2080[3] = r2139.3
p2080[4] = r0899.4
p2080[5] = r0899.5
p2080[6] = r0899.6
p2080[7] = r2139.7
p2080[8] = r2197.7
p2080[9] = r0899.9
p2080[10] = r2199.1
p2080[11] = r0056.13
-
p2080[13] = r2135.14
p2080[0] = r0899.0
p2080[1] = r0899.1
p2080[14] = r2197.3
Interconnection
parameters
[2503.7]
[2548.7]
[2503.7]
[2503.7]
[2503.7]
[2548.7]
[2534.7]
[2503.7]
[2536.7]
[2522.7]
-
[2548.7]
-
[2503.7]
[2503.7]
[2534.7]
[Function diagram]
Internal status word
[2610]
[8060]
[2610]
[2610]
[2610]
[8065]
[8010]
[2503]
[8010]
[6060]
-
[8016]
-
[2610]
[2610]
[8011]
[Function diagram]
Signal source
<1>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
<2>
Inverted
p2080[15] = r0836.0
<4>
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......