Technical data
11.9 Electromagnetic Compatibility
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
353
11.9
Electromagnetic Compatibility
The SINAMICS G120 drives have been tested in accordance with the EMC Product
Standard EN 61800-3:2004.
Details see declaration of conformity
Note
Install all drives in accordance with the manufacturer’s guidelines and in accordance with
good EMC practices.
Use screened cable type CY. Maximal cable length is 15 m.
Table 11- 6 Compliance Table
Category C2 - First Environment - Professional Use
Order number
Remark
6SL3525-0PE17-*A*0
6SL3525-0PE21-*A*0
6SL3525-0PE23-*A*0
6SL3525-0PE24-*A*0
6SL3525-0PE25-*A*0
6SL3525-0PE27-*A*0
All inverters with integrated Class A filters.
The inverter meets the requirements for category C2 for conducted emis-
sions.
In a domestic environment this product may cause radio interference in
which case supplementary mitigation measures may be required.