SIMOVERT P 6SE21 Series Inverters
English
Operating Instructions
Siemens plc 1995
G85139–A1615–U156–A
02.95
12
3. MECHANICAL INSTALLATION
High voltages are generated within this equipment. It must only be installed and operated by qualified
personnel who are familiar with the equipment, its operating requirements and instructions.
The User is responsible for installation of the motor, drive controller, transformer and other devices
in accordance with regulations and local safety codes which may apply.
Adequate protective clothing (e.g. safety gloves, goggles, etc.) should be worn by the person
installing this equipment.
Failure to observe the appropriate warnings and regulations may result in serious injury or death.
WARNING
The inverter must be installed in a vertical position and fixed to a solid surface via its four mounting holes. It is suitable
for wall–mounting or installation within a cubicle.
All inverter variants are air–cooled. Ensure that a free space of at least 100 mm (4 in.) is left both above
and below the unit to allow an unimpeded air flow.
Avoid subjecting the inverter to excessive shock and vibration.
CAUTION
Installation drawings for the inverters are shown on the next page.