Description
3.3 Installation
Smoke extraction motors
22
Operating Instructions, 03/2016, 5 610 80000 40 018
3.3.7
Degree of protection
The machine has a type of protection as stamped on the rating plate, and can be installed in
dusty or humid environments.
Limit values for the standard version
Relative humidity for ambient temperature T
amb
40 °C
Max. 55 %
Ambient temperature
-20 °C to +40 °C
Installation altitude
≤
1000 m
Air with normal oxygen content, usually
21 % (V/V)
For differing environmental conditions, the values on the rating plate and the accident plate
apply.
The motor is suitable for tropical climates.
3.3.8
Optional built-on and built-in accessories
DANGER
Functional endurance when faults/fires occur
Non-observance can lead to death, serious injury or material damage.
In the event of a fault (e.g. fire), disable protective devices or bypass them.
In addition to the current-dependent overload protective device located in the connecting
cables, use temperature sensors integrated in the stator winding in order to monitor the
temperature and protect the stator winding from overheating.