Degree of protection
The degree of protection the machines feature is stated on the rating plate. They can
be installed in dusty or humid environments.
WARNING
Dangerous voltage
Condensation drain holes (optional)
Inserting objects into the condensation drain holes can damage the
winding and can result in death, serious injury and damage to property!
Note the following to maintain the degree of protection:
●
Switch off the machine so that it is in a no-voltage condition, before
you open the condensation drain holes.
●
Close the condensation drain holes (e.g. using T-plugs) before
commissioning the machine.
Note
Storage
If the machines are used or stored outdoors, we recommend keeping them under a
shelter or an additional cover.
●
Avoid exposing them to direct, intense solar radiation, rain, snow, ice, or dust for
extended periods.
●
If necessary, please consult us or seek advice regarding technical issues.
Environmental requirements
The machines are suitable for operation in tropical climates.
Guide value for the standard version 60 % relative humidity at an ambient
temperature of (T
amb
) 40 °C.
Ambient temperature: -20 °C to +40 °C
Installation altitude: ≤ 1000 m
Air with normal oxygen content, usually 21 % (V/V)
If the environmental requirements are different from the details listed here, then the
values on the rating plate will apply.
Содержание SIMOTICS 1LA
Страница 35: ...INDUSTRY PROCESS AND AUTOMATION SOLUTIONS C A F S VF W A T E X INCLUDED Installation use and service manual ...
Страница 36: ......
Страница 85: ...49 ...
Страница 88: ...COD 1261 R3 INDUSTRY PROCESS AND AUTOMATION SOLUTIONS w w w b o n f i g l i o l i c o m ...
Страница 89: ... i Bonfiglioli Trasmital 300 series Installation use and service manual ATEX INCLUDED ...
Страница 130: ... Bonfiglioli Trasmitol 41 ...
Страница 132: ......
Страница 135: ...SPRING APPLIED BRAKE WITH ELECTROMAGNETIC RELEASE 38 mm Page 2 of 2 180 Volts 16 39599 ...