Operating situations and characteristics can vary widely. For this reason, only general
maintenance intervals are specified here. Maintenance intervals should therefore be scheduled
to suit the local conditions (dirt, starting frequency, load, etc.).
Table 9-3
Operating period intervals
Measures
Operating period intervals
Intervals
Initial inspection
After 500 operating hours
After 1/2 year at the latest
Relubrication (optional)
See the lubricant plate
Clean
Depending on the degree of pollution
Main inspection
Approximately every 16000 operating
hours
After two years at the latest
Drain condensate
Depending on the climatic conditions
9.6.7
Re-greasing
For machines with regreasing system, relubrication intervals, grease quantity and grease grade
are provided on the lubricant plate. Additional data can be taken from the main machine rating
plate.
Grade of grease for standard motors (IP55) UNIREX N3 - ESSO.
Note
It is not permissible to mix different types of grease.
Prolonged storage periods reduce the useful lifetime of the bearing grease. Check the condition
of the grease if the equipment has been in storage for more than 12 months. If the grease is
found to have lost oil content or to be contaminated, the machine must be immediately
relubricated before commissioning. For information on permanently-greased bearings, please
refer to the section titled Rolling bearings (Page 100).
Procedure
To relubricate the rolling bearings, proceed as follows:
1. Clean the grease nipples at the drive end and non-drive end.
2. Press-in the specified grease and amount of grease according to the data stamped on the
lubrication plate.
– Please observe the information on the rating and lubricant plates.
– Regreasing should be carried out when the motor is running (max. 3600 rpm).
Maintenance
9.6 Inspection and maintenance
1FU9
96
Operating Instructions, 07/2020, A5E46712792A
Содержание SIMOTICCS A 1FU9
Страница 1: ...Operating Instructions 1FU9 SIMOTICS A 07 2020 Edition Synchronous motors www siemens com ...
Страница 2: ......
Страница 42: ...Preparing for use 4 11 Converter operation 1FU9 40 Operating Instructions 07 2020 A5E46712792A ...
Страница 58: ...Assembly 5 6 Installing the machine 1FU9 56 Operating Instructions 07 2020 A5E46712792A ...
Страница 80: ...Commissioning 7 3 Switching on 1FU9 78 Operating Instructions 07 2020 A5E46712792A ...
Страница 110: ...Spare parts 1FU9 108 Operating Instructions 07 2020 A5E46712792A ...
Страница 120: ...Technical data B 1 Tightening torques 1FU9 118 Operating Instructions 07 2020 A5E46712792A ...
Страница 124: ...Index 1FU9 122 Operating Instructions 07 2020 A5E46712792A ...
Страница 125: ......
Страница 126: ...Germany www siemens com drives Siemens AG Digital Industries Motion Control Postfach 31 80 91050 ERLANGEN ...