05.01
3.5 Overview, position sensing
3-78
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
3.5
Overview, position sensing
Table 3-5
Assignment, motor measuring systems to control unit
Drive control unit, High Performance (FD mode)
Drive control unit, High Performance (MSD mode)
Drive control unit, High Standard (FD mode)
Drive control unit, High Standard (MSD mode)
Drive control unit 611 universal HRS resolver
Drive control unit 611 universal HRS– 1 Vpp voltage signals
Motor type
Encoder system
Yes
1FK
Servo motor
Resolver
Yes
Yes
Yes
1FT/1FK
Servo motor
Incremental encoder 1 Vpp
Yes
Yes
Yes
1FT/1FK
Servo motor
Multiturn absolute encoders
Yes
Yes
Yes
1FN
Linear motor
Incremental encoder (Hall sensor box) 1 Vpp
Absolute encoder
Yes
Yes
Yes
1PH4/6/7
Main spindle motor
Incremental encoder 1 Vpp
Yes
Yes
Yes
1FE1/1PH2/1PM/2SP1
Main spindle motor
Incremental encoder (hollow–shaft encoder) 1 Vpp
(toothed wheel or magnetic)
Yes
Yes
Yes
1FW
Built–in torque motor
Incremental encoder 1 Vpp
Absolute encoder
Yes
Yes
Yes
Yes
1LA standard motor
Encoderless (sensorless)
Table 3-6
Indirect position (motor rotor position) and motor speed sensing digital controls
Version of
the
control
board
Indirect position (motor rotor position) and motor speed
sensing digital controls
Drive
control
High Perfor–
mance/
High Stan-
dard
1FT6
1FK
1PH
1PM
SIMODRIVE
drive module
SINUMERIK
840D powerline
drive bus
Drive bus
Incremental
l
50 m
3 Motor Selection, Position/Speed Sensing