English 

Important 

 

 

This quick start manual is only intended for use by professional installers who have 
an adequate working knowledge of video systems! This manual outlines the most 
important information about the SIMATRIX NEO II video matrix system. It is, 
however, vital that you also refer to the full operating instructions. 

Legende 

 

Illustration A

:

 

Telemetry ports for dome camera types

 

RJ9, RS422 / RS485 

Port-No. 

Protocol* 

Interface parameters* 

Telemetry Port 1 

CCDA 

9k6, 8n1 

Telemetry Port 2 

SCU 

2k4, 8E1 

Telemetry Port 3 

Sivis Minidome 

19k2, 8E1 

Telemetry Port 4 

Pelco D 

9k6, 8N1 

*changeable by control software 

Pin allocation for the "Telemetry Port" 4-pin RJ11 

sockets

 

Pin 

Signal 

Pin 

Signal 

 

 
 
 

+TX 

+RX 

-TX 

-RX 

 
Illustration B

:

 

Keys and interfaces 

1  Reset

 (red key): 

In combination with the green 

Default

 key, this key restores the factory settings 

and activates alarm program 2. 
All user-defined settings will be overwritten 

2  Default

 (green key), see 

Reset

 

3  COM2/3: 

Serial interfaces (with Y cable) 

RS232 communication interface for data exchange with external computers and 
other systems 
Data exchange rate: 19200 Baud. 

Pin 

COM2/3 

COM4 

1, 4, 6, 7 

N.C. 

N.C. 

RX COM2 

RX COM2 

TX COM2 

TX COM2 

GND 

GND 

RX COM3 

N.C. 

TX COM3 

N.C. 

4  COM4

: Serial interface 

RS232 communication interface for data exchange with external computers and 
other systems 
Data exchange rate: 19200 Baud. 

5  Alarm 1-16 / TTY out: 

37-pin socket for 16 alarm input signals and 8   camera head control signals 
Note: the alarm signals must be presented for at least 100 ms. 

Pin 

Function 

Pin 

Function 

Alarm input    1 / 17 

20 

–TX    TTY 1 /    9 

Alarm input    2 / 18 

21 

+TX    TTY 1 /    9 

Alarm input    3 / 19 

22 

–TX    TTY 2 / 10 

Alarm input    4 / 20 

23 

+TX    TTY 2 / 10 

Alarm input    5 / 21 

24 

–TX    TTY 3 / 11 

Alarm input    6 / 22 

25 

+TX    TTY 3 / 11 

Alarm input    7 / 23 

26 

–TX    TTY 4 / 12 

Alarm input    8 / 24 

27 

+TX    TTY 4 / 12 

Alarm input    9 / 25 

28 

–TX    TTY 5 / 13 

10 

Alarm input 10 / 26 

29 

+TX    TTY 5 / 13 

11 

Alarm input 11 / 27 

30 

–TX    TTY 6 / 14 

12 

Alarm input 12 / 28 

31 

+TX    TTY 6 / 14 

13 

Alarm input 13 / 29 

32 

–TX    TTY 7 / 15 

14 

Alarm input 14 / 30 

33 

+TX    TTY 7 / 15 

15 

Alarm input 15 / 31 

34 

–TX    TTY 8 / 16 

16 

Alarm input 16 / 32 

35 

+TX    TTY 8 / 16 

17, 18, 19 

GND 

36, 37 

GND 

6  LAN

 

8P8C-socket (RJ45) for data exchange with external computers and other 
systems via ethernet 10/100-Base-T 

7  Syslink

 

RJ9 connection for an extension unit and /or alarm box. 

8  Alarm Out

 

25-pin Sub-D socket with 8 Open-Collector outputs for external device control 
and collector relay with 2 voltage-free signal switching contacts (alarms and/or 
video signal interruption) 

Pin 

Function 

Pin 

Function 

  1 

N.C. 

14 

Open Collector    D0 

  2 

N.C. 

15 

Open Collector    D1 

  3 

N.C. 

16 

Open Collector    D2 

  4 

Relay N.O. contact 1 

17 

Open Collector    D3 

  5 

Relay change-over 

contact

 1 

18 

Open Collector    D4 

  6 

Relay N.C. contact 1 

19 

Open Collector    D5 

  7 

GND 

20 

Open Collector    D6 

  8 

Relay N.O. contact 2 

21 

Open Collector    D7 

  9 

Relay change-over 

contact 2 

22 

Conform connection 

diodes (D0-D7)(1) 

10 

Relay N.C. contact 2 

23 

GND 

11, 12, 13 

N.C. 

24, 25 

N.C. 

9  Alarm 17-32 / TTY out: 

see 5, alarm 1-16 / TTY out

 

Illustration C

Type plate and CE-mark 

Illustration D

:

 

Power supply / fuses

 

Fuses: 2 x 1.6 A (slow-blow) 
To open, push the catch between the two fuses upwards. 

Illustration E

:

 

Status message after power up (front display) 

Illustration F

 

Maximum of 128 BNC sockets for video input signals (75Ω) 

Illustration G

 

Maximum of 32 BNC sockets for video output signals (75Ω) 

Illustration H

 

8 RJ12 sockets for operating devices, 6-pin 

Pin 

Function 

 

 

 
 
 
 
 

GND 

– RX 

+ RX 

– TX 

+ TX 

+12V 

Installation and set-up 

 

When installing the unit, ensure that the 

ventilation slots at the side are not 

obstructed in any way!

 If necessary, feed cooling air from the right-hand side of the 

housing (front/display side) 

Step 1: Provisionally connect the SIMATRIX NEO II to the electrical supply

 

Required power supply: TN network (to VDE 0100, section 300 or EN 60950) 
Voltage range: 115 / 230 Volt (+10% / -15%) 
Once the system has been connected to the electrical supply, and assuming the 
device is in good operating order, the following messages will appear in the front 
display; "waiting for CPU" (start-up message) followed by "active", after this the 
system time will be displayed. 
To continue installation, you must now unplug the unit at the mains! 

Step 2: additional video input / output modules (SIMNEO-IM / -SOM) 

Open the chassis and install the additional video modules Please refer to the 
detailled operation manual of SIMATRIX SYS for installation and setup. 

Step 3: Connect the cameras 

Step 4: Connect the monitors 

Step 5: Connect the operating devices 

Step 6: Connect any other devices

 

if applicable, connect system extensions and any other devices. 

Step 7: Connect the control PC 

Connect the control PC to COM2, COM4 or LAN using the null-modem cable. 

Step 8: Connect the SIMATRIX NEO II to the electrical supply 

Step 9: Install the control software and the LAN configurator 

Use the

 

CD supplied with the unit to install the

 

control program. Then start up the 

control program. 

Step 10: LAN configuration 

If the system will be configured via LAN, please start the net config tool at first and 
enter the IP-address 

Step 11: Set the system time in the SIMATRIX NEO II 

You must start the system's real time clock if it is not active ("No Time!" appears in 
the display),as otherwise a number of important system functions, such as alarm 
sequencing, will not be available. 
Control software: System real time clock / Permanent timers button 

Step 12: Save base parameters

 

Control software: Base parameter button 
Camera and monitor settings 

Step 13: Save alarm base parameters

 

Control software: 
Alarm base parameters button 
Alarm sensor settings 

Step 14: Save camera labels

 

Control software: Camera labels button 

Step 15: Test cameras, monitors and operating devices 

Control software: Controls/ signal reception button 

Step 16: Alarm sensor to camera allocation

 

Control software: Sensors / Camera groups button 

Step 17: Further programming

 

If applicable, enter further parameters in order to tailor the function of the SIMATRIX 
NEO II to suit individual operating needs and the rest of the system. 

Step 18: Make a back-up of the parameter settings and store the back-up close 
to the system. 

Dat

a

 a

n

d

 d

e

si

g

n

 s

u

b

je

ct 

to

 c

h

a

n

g

e

 wit

h

o

u

n

o

ti

ce

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

©

 2

0

0

8

 S

ie

m

e

n

s B

u

ild

in

g

 T

e

ch

n

o

lo

g

ies

F

ir

e

 a

n

d

 S

e

c

u

rity

 P

ro

d

u

c

ts

 

Отзывы: