background image

SIMATIC VS710

Quick Reference Guide

34

SIMATIC VS 710

A5E00032597-02

Содержание Simatic VS 710

Страница 1: ...SIMATIC VS 710 Quick Reference Guide A5E00032597 02 Edition 11 2001 ...

Страница 2: ...is manual for agreement with the hardware and software described Since deviations cannot be en tirely ruled out we cannot guarantee full agreement However the data in this Quick Reference Guide are reviewed regularly and any necessary corrections included in subseqeuent editions Sugges tions for improvement are welcome Technical data subject to change Disclaimer of Liability Copyright W Siemens AG...

Страница 3: ...Bracket 8 Lens Socket 8 2 3 Hardware Interfaces 9 2 4 Power Supply Connector Pinout 10 24 VDC Power Supply 11 2 5 Digital Input Output Connector Pinout 12 Wiring Diagram Digital Input Points 13 Wiring Diagram Digital Output Points 14 2 6 DP Connector Pinout 15 2 7 VGA Connector Pinout 16 2 8 RS232 Connector Pinout 17 2 9 IDE Flashdisk 18 3 Connecting the VS 710 19 3 1 Safety Recommendations 19 3 2...

Страница 4: ... Operating DOS 6 22 and SETUP 24 4 4 Installing older ProVision versions on Your VS 710 25 5 Technical Specifications 26 5 1 General Specifications 26 5 2 Digital I O Interface 29 6 Certification 31 6 1 Certification for the USA and Canada 31 UL CSA Certification 31 FM Approval 32 6 2 Certification for Europe 33 EMC Guidelines 33 Declaration of Conformity 33 Observing the Setup Guidelines 33 ...

Страница 5: ...tion Top quality image representation and resolution for static and moving images High clock speed for networked decentralized automation solutions Continuous remote parts inspection Video image can be shown on SVGA monitors Digital I O to programmable controller PROFIBUS DP slave functionality with a transmission speed of up to 12 Mbps Can be configured by host PC via a serial port or PROFIBUS DP...

Страница 6: ... is included along with the basic product VS 710 OEM VS 710 6GF1710 2AA 6GF1710 3AA Configurable using customized C C programs Configurable using ProVision 6GF8007 1AA0 software package and higher VS 710 Package VS 710 basic unit with ProVision run time software Tool diskette 1 with MS DOS 6 22 1 Standard software licence agreement Mounting bracket and two M4 fixing screws 2 Ferrite sleeves This h...

Страница 7: ... Power supply cable 6GF9002 1CA Digital I O cable 6GF9002 1CB DP cable PROFIBUS line 6XV1830 0EH10 PROFIBUS connector 6ES7972 0BA40 0XA0 without PG socket 6ES7972 0BB40 0XA0 with PG socket Note The accessories listed in the above table are not supplied with the device and must be ordered separately Standard accessories are listed in catalog ST70 and ST50 ...

Страница 8: ... C mount standard lens socket High resolution CCD chip 782x582 with square pixels pixel identical scanning offset setting used CCD Chip size 6 5 mm H x 4 8 mm V Restart reset full frame shutter with an exposure range of 1 50 1 10000s half image and full image modes Parameter assignment for image formats up to 768x512 100 MHz 80486 CPU AMD with direct image buffer access 16 Mbyte main memory DRAM m...

Страница 9: ...support socket M4 screw threads for mounting attachments are located on the underside of the metal casing Choose whichever mounting option best suits your needs Directly onto the casing using the M4 screw threads To the support socket on the casing Using the mounting bracket supplied not included in the VS 710 OEM package Mounting bracket M4 screw threads 1 4 support socket Figure 1 Mounting Fixtu...

Страница 10: ...ting with or without a mounting bracket attached 31 13 5 16 5 65 5 16 5 10 131 5 143 1 5 120 screw threads on 3 sides depth 8mm 148 21 5 22 5 12 5 12 5 80 6 58 M4 M4 M4 American coarse thread 1 4 20 UNC depth 8mm depth 6mm depth 8mm depth 8mm no mating connector lens starts here M4 8 mm deep Figure 2 Dimensions with No Mounting Bracket Attached ...

Страница 11: ...k Reference Guide SIMATIC VS 710 A5E00032597 02 7 6 3 86 6 98 96 5 22 5 1 5 147 108 Figure 3 Dimensions with a Mounting Bracket Attached Side Mounting 71 Figure 4 Dimensions with a Mounting Bracket Attached Top Mounting ...

Страница 12: ...front panel leaving the other three sides of the casing free for other mounting alternatives M 4 screws Mounting bracket set screw 1 Figure 5 VS 710 with Mounting Bracket Attached Lens Socket The lens socket fits all commercial C mount standard lenses 1 Note the set screw on the lens socket is meant for factory settings only A readjustment of the lens position is not allowed ...

Страница 13: ...range of 20 4 to 28 8 V Round 12 pin plug with two 24 volt digital input points including two interrupt controllers and four 24 volt digital optocoupler output points including a flash controller 9 pin subminiature D connector PROFIBUS DP interface with a data transmission rate of up to 12 Mbps 3 row 15 pin subminiature D connector SVGA monitor port 9 pin subminiature D connector RS232 interface w...

Страница 14: ...ector Pinout Note The pin numbers are as seen on the rear casing with the unit in an upright position Warning VN 24 VDC 500 mA Voltage range 20 4 to 28 8 volts The power supply connector has the following pinout Pin Signal 1 24 volts 2 24 volts 3 Ground 4 Ground Maximum current per pin 1 A The connector acts as a means of isolation from the 24 volt power supply ...

Страница 15: ...ts of your programmable logic controller may be damaged and there is a risk of personal injury The DC load power supply must fulfill the following requirements Only extra low voltage DC 60 V which is isolated from the supply may be used as the load current power supply The protective separation can be achieved in accordance with the requirements set out in VDE 0100 Part 410 HD 384 4 41 IEC 364 4 4...

Страница 16: ...Not assigned 9 Not assigned 10 24 volts L 11 Ground 24 volts M 12 Digital input point 1 2 DI 1 1 Simultaneous flash signal under ProVision 2 Triggering interrupt Maximum cable length 10 m shielded 2 input points optically isolated All input points are referenced to a common ground Rated voltage DC 24V 4 output points optically isolated All output points are referenced to a common ground Output cur...

Страница 17: ...ng Diagram Digital Input Points Pin 1 L M 2 M M 3 DO 0 4 DO 1 5 DO 2 6 DO 3 DI 0 7 DI 0 DI 0 8 9 10 L 11 M 12 DI 1 DI 1 Figure 9 Connection Diagram Showing Digital Input Points Internal Data Bus Minternal DI 0 DI 1 Figure 10 Basic Circuit Diagram Showing Digital Input Points ...

Страница 18: ...Diagram Digital Output Points Pin 1 L L 2 M 3 DO 0 DO 0 4 DO 1 DO 1 5 DO 2 DO 2 6 DO 3 DO 3 7 DI 0 8 9 10 L 11 M M 12 DI 1 Figure 11 Connection Diagram Showing Digital Output Points L M Minternal Internal Data Bus DO Figure 12 Basic Circuit Diagram Showing Digital Output Points ...

Страница 19: ... Output 7 Not assigned 8 LTG_A Signal line A Output 9 Not assigned Shield On connector casing 1 Control signal for received data flow The control is 1 active when the programmable controller is sending 2 0 V line of the 5 V power supply 3 P5ext power supply 5 V of the 5 V power supply powers bus terminator The DP interface operates on the slave principle and is designed as a floating interface It ...

Страница 20: ...3 15 pin subminiature D connector Figure 14 VGA Socket Connector Pin Signal 1 Red 2 Green 3 Blue 4 Not assigned 5 Digital ground 6 Digital ground 7 Digital ground 8 Digital ground 9 Not assigned 10 Digital ground 11 Not assigned 12 Not assigned 13 Horizontal sync 14 Vertical sync 15 Not assigned Shield On connector casing Note Connect your VGA monitor with the standard VGA cable The distance betwe...

Страница 21: ...in subminiature D connector Figure 15 RS232 Connector Pin Signal 1 DCD data carrier detect 2 RXD receive data 3 TXD transmit data 4 DTR data terminal ready 5 Ground 6 DSR data set ready 7 RTS request to send 8 CTS clear to send 9 RI ring indicator Shield On connector casing The serial port is a fully fledged RS232 interface The ground pin is referenced to the internal ground The interface is confi...

Страница 22: ... the host keyboard and host diskette drive read only can be used as if they were directly connected to the VS 710 Note You can use HOSTKEY to set up the connection with the host PC see Section 4 1 2 9 IDE Flashdisk The VS 710 enables you to use solid state memory like a hard disk drive This flashdisk solid state memory can be used to boot MS DOS and store application programs Note The deleting and...

Страница 23: ...e applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens This product can only function properly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Cleaning the Unit To clean the unit use a soft cotto...

Страница 24: ...Environment The VS 710 operates in two basic modes 1 Configure mode The VS 710 is connected to a programming device PC via RS232 or PROFIBUS DP and is supplied with user programs and configuring data 2 Productive mode The VS 710 is in the target operating mode and receives jobs or delivers processed data through digital I O RS232 and PROFIBUS DP interfaces It communicates with actuators sensors co...

Страница 25: ...Connection via VS 710 with ProVision VS 710 OEM RS232 interface Yes Yes with Hostkey DP interface Yes No Digital I O Yes No Function in Productive Mode Connection via VS 710 with ProVision VS 710 OEM RS232 interface Yes Yes DP interface Yes Yes Digital I O Yes Yes as of ProVision V2 0 A suitable user program is required ...

Страница 26: ...s components of the VS 710 For this you need a functioning serial connection and HOSTKEY must be activated before rebooting the VS 710 The program is supplied on a diskette along with the product and is started from the host PC The VS 710 monitor takes over the function of operator monitor once the connection has been established 1 Insert the HOSTKEY diskette in the diskette drive of the host PC h...

Страница 27: ...2 COM2 S96 9600 bps S192 19200 bps S384 38400 bps S576 57600 bps S1152 115200 bps NOF Do not check for floppy disk when loading HOSTKEY V Verbose mode display HOSTKEY messages Call without specifying parameters Activates the COM1 interface with a rate of 115 2 Kbps Operator Input to HOSTKEY Once emulation has been started key commands go to the VS 710 Exceptions are CTRL X Aborts HOSTKEY CTRL Alt ...

Страница 28: ...p the VS 710 internal drive C Remote control of VS 710 from host PC Perform SETUP functions To reboot the VS 710 Press Ctrl Alt F10 Press F2 to start SETUP Go to MS DOS Go to SETUP Figure 17 Using HOSTKEY to Operate the VS 710 Note To avoid taking up too much memory only a minimal subset of DOS 6 22 is loaded on the VS 710 Other DOS utilities are available on Tool Diskette 1 You cannot copy files ...

Страница 29: ... Connect the host PC and VS 710 via the RS232 interface Watch out for system messages such as Change diskette Installation complete Press Ctrl Alt F10 key combination to restart VS 710 Press Ctrl X to exit Hostkey Type in A install 1 to delete old files and load new files from A to C Insert diskette 1 in the diskette drive of the host PC Wait until MS DOS prompts with C Figure 18 Installing ProVis...

Страница 30: ...0 mm W x H x D with no mounting bracket attached Weight Approx 0 750 kg without lens Interfaces to S7 M7 C7 to PC RS485 12 Mbps RS232 115 Kbps Power Supply Supply voltage VN S Input voltage protected against polarity reversal S Voltage interruption can be jumpered 24 VDC 20 4 to 28 8 VDC safety extra low voltage SELV The VS 710 has no integrated protection against high energy surge pulses in the µ...

Страница 31: ...oltage supply lines 2 kV according to IEC 1000 4 4 burst 1 kV according to IEC 1000 4 5 µs pulse line to line 2 kV according to IEC 1000 4 5 µs pulse line to ground With protective element lightning conductor KT type AD 24 V from the Dehn company Noise immunity on signal lines 2 kV according to IEC 1000 4 4 burst 2 kV according to IEC 1000 4 5 µs pulse line to ground Noise immunity against dischar...

Страница 32: ...ation S Storage trans port 1080 795 hPa 1000 m to 2000 m 1080 660 hPa 1000 m to 3500 m Mechanical Environmental Conditions without lens Vibration S Operation S Storage trans port Tested according to IEC 68 2 6 10 to 58 Hz amplitude 0 075 mm 58 to 500 Hz acceleration 9 8 m s2 5 to 9 Hz amplitude 3 5 mm 9 to 500 Hz acceleration 9 8 m s2 Shock S Operation S Storage trans port Tested according to IEC ...

Страница 33: ...d current supply L 24 VDC Permitted rated voltage Load current supply L 20 4 V to 28 8 V Current consumption L Depends on assignment Number of simultaneously controllable inputs 2 Number of simultaneously controllable outputs 4 Isolation Yes optocoupler Permitted potential differences S Between M connections S Between input M connection and central grounding point S Isolation tested with 500 VDC I...

Страница 34: ... Selecting an Actuator Output voltage S With signal 1 S With signal 0 L 1 5 v Max 3 V Output current S With signal 1 rated value permitted range S With signal 0 residual cur rent 0 5 A From 5 mA to 0 6 A Max 0 1 mA Load on lamps Max 5 W Parallel connection of 2 outputs No Maximum operating frequency S With ohmic load lamp load S With inductive load 500 Hz 2 0 Hz at 0 5 A Switching delay Max 400 µs...

Страница 35: ...ap proval has been issued as indicated Underwriters Laboratories UL in accordance with Standard UL 508 Underwriters Laboratories UL in accordance with Canadian Standard C22 2 No 142 UL Recognition Mark Canadian Standard Association CSA in accordance with Stan dard C22 2 No 950 or C22 2 No 142 FM approval in accordance with Factory Mutual Approval Standard Class Number 3611 3600 3810 Class I Divisi...

Страница 36: ...ry or property damage can result Unless the location is known to be non hazardous do not connect or disconnect plugs fuses switches etc while the unit is in operation as physical injury and damage to property may result Do not connect or disconnect live circuits unless the location is known to be non hazardous Warning WARNING DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS LOCATION IS KNOWN TO BE N...

Страница 37: ...ce Immunity to Interference Residential commercial and light industry EN 50081 1 1992 EN 50082 1 1992 Industry EN 50081 2 1993 EN 50082 2 1995 Declaration of Conformity In accordance with Section 10 2 of the above EU Directive the EU Declaration of Conformity and related documents will be held available for inspection by the competent authorities at Siemens Aktiengesellschaft Bereich Automatisieru...

Страница 38: ...SIMATIC VS710 Quick Reference Guide 34 SIMATIC VS 710 A5E00032597 02 ...

Отзывы: