Connecting to the supply voltage (SELV)

● The power supply is connected using a 4-pin plug-in terminal block.
● The power supply can be connected redundantly. Both inputs are isolated. There is no 

distribution of load. When a redundant power supply is used, the power supply unit with the 

higher output voltage supplies the IE Switch X-300 alone.

● The power supply is connected over a high resistance with the enclosure to allow an 

ungrounded set up. The two power inputs are non-floating.

Terminal block assignment (4-pin)

Table 6-2

Pinout of the 24 V safety extra-low voltage (SELV)

Pin number

Assignment

Labeling (example)

Pin 1

L1+ (24 V DC)

Pin 2

M1

Pin 3

M2

Pin 4

L2+ (24 V DC)

Connecting

6.6 Connecting the external 24 VDC power supply

SCALANCE X-300M PoE

Compact Operating Instructions, 11/2019, A5E02630810-13

49

Содержание SIMATIC SCALANCE X-300M PoE

Страница 1: ...LANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 Introduction 1 Safety notes 2 Recommendations on network security 3 Device description 4 Assembling 5 Connecting 6 Technical data 7 Dimension drawings 8 Approvals 9 Appendix A ...

Страница 2: ...personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturer...

Страница 3: ... S7 300 standard rail 33 5 4 Installation on a DIN rail 34 5 5 Wall mounting 35 5 6 Installation of modular devices 36 5 6 1 Installation and removal of media modules 36 5 6 2 SFP installation in SFP media module 41 6 Connecting 43 6 1 Safety when connecting up 43 6 2 Notes on commissioning 45 6 3 Wiring rules 46 6 4 Grounding 47 6 5 24 VDC signaling contact 47 6 6 Connecting the external 24 VDC p...

Страница 4: ...ovals 63 9 1 Mechanical stability in operation 69 A Appendix 71 A 1 Connector system M12 X coded according to IEC 61076 2 109 71 Index 73 Table of contents SCALANCE X 300M PoE 4 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 5: ... a device only the device name is used X308 2M PoE Variant For a variant of the device the device name has the appropriate variant added to it in brackets Overview of technical documentation on the IE switches SCALANCE X 300 You will find the technical documentation for the SCALANCE X 300 product line in the following documents Configuration manual PH available as PDF document The configuration ma...

Страница 6: ...K XR 300M EEC SCALANCE XR 300M EEC A5E02630809A BAK X 300M PoE SCALANCE X 300M PoE A5E02630810A BAK XR 300M PoE SCALANCE XR 300M PoE A5E02661178A BAK MM900 SCALANCE MM900 media modules A5E02630805A BAK SFP Information sheet SCALANCE SFP plug in transceivers A5E02630804A A5E02648904A Device description technical specifications information on instal ling connecting and commissioning Documentation on...

Страница 7: ...ponents you will find information on other SIMATIC NET products that you can operate along with the devices of this product line in an Industrial Ethernet network There you will find among other things optical performance data of the communications partner that you require for the installation You will find the system manuals here On the data medium that ships with some products Product CD product...

Страница 8: ... are in place For additional information on industrial security measures that may be implemented please visit https www siemens com industrialsecurity https www siemens com industrialsecurity Siemens products and solutions undergo continuous development to make them more secure Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product ve...

Страница 9: ... at public disposal sites For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact Product return https support industry siemens com cs ww en view 109479891 Note the different national regulations SIMATIC NET SCALANCE C PLUG OLM Trademarks The following and possibly other names not identified by the...

Страница 10: ...Introduction SCALANCE X 300M PoE 10 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 11: ... explosion WARNING EXPLOSION HAZARD Do not open the device when the supply voltage is turned on Safety notices when using the device according to Hazardous Locations HazLoc If you use the device under HazLoc conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion This equipment is suitable for use in Class I Division ...

Страница 12: ...Safety notes SCALANCE X 300M PoE 12 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 13: ...area For communication via non secure networks use additional devices with VPN functionality to encrypt and authenticate the communication Terminate management connections correctly WBM Telnet SSH etc Physical access Restrict physical access to the device to qualified personnel because the plug in data medium can contain sensitive data Lock unused physical interfaces on the device Unused interface...

Страница 14: ... a preset SSL certificate with key Replace this certificate with a self made certificate with key We recommend that you use a certificate signed either by a reliable external or by an internal certification authority Use a certification authority including key revocation and management to sign certificates Make sure that user defined private keys are protected and inaccessible to unauthorized pers...

Страница 15: ...nabled change the community names If no unrestricted access is necessary restrict access with SNMP Use the authentication and encryption mechanisms of SNMPv3 Use secure protocols when access to the device is not prevented by physical protection measures If you require non secure protocols and services operate the device only within a protected network area Restrict the services and protocols avail...

Страница 16: ... Open Yes No PROFINET IO Service TCP 84 Open Open No No HTTPS TCP 443 Open Open Yes Yes DHCP UDP 68 Open when config ured Open No No SNTP UDP 123 Open when config ured Closed No No NTP secure Yes SNMP UDP 161 Open when config ured Open Yes Yes SNMPv3 RADIUS UDP 1812 1813 Open Open Yes No PROFINET IO UDP 34964 UDP 49152 49153 Open when config ured Open No No These ports are assigned dynamically and...

Страница 17: ...ch X 300 is made up of several parts that have the following meaning RPSDFW KRXVLQJ R 5DFN GHYLFH 1XPEHU RI HOHFWULFDO SRUWV RU WRWDO QXPEHU RI SRUWV LQ PRGXODU GHYLFHV 1XPEHU RI RSWLFDO SRUWV RU QXPEHU RI PRGXOH VORWV LQ PRGXODU GHYLFHV 6WDQGDUG YHUVLRQ TS 7UDQVSRUWDWLRQ 6 VWHP 6WDQGDUG YHUVLRQ EEC SDQGHG WHPSHUDWXUH UDQJH PoE 3RZHU RYHU WKHUQHW HYLFHV ZLWKRXW PRGXOH VORWV M 0RGXODU GHYLFH QWHUID...

Страница 18: ...t names will be used without extra information on the type or number of interfaces Examples X 300 stands for non modular devices with a compact housing XR 300 means all rack devices X 300M means all modular devices etc Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts there is no guarantee that the device will function according to the specif...

Страница 19: ...pplied with a SCALANCE X 300M PoE A device with a C PLUG exchangeable medium A 4 pin terminal block for the power supply A 2 pin terminal block for the signaling contact A product CD with documentation and software Device description 4 1 Product overview SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 19 ...

Страница 20: ...lar ports via module slots Two media modules optical or electrical as required can be combined using slots S1 S2 depending on the application End devices and other network segments are connected according to the media modules being used Note When shipped the slots for the media modules have a dummy cover fitted Figure 4 1 SCALANCE X308 2M PoE with dummy covers Device description 4 2 Product proper...

Страница 21: ... selected media module Refer to the section Media module installation in slot Example Fitted with media modules MM992 2 and MM991 2 Figure 4 2 SCALANCE X308 2M PoE with MM992 2 and MM992 2SFP Column 1 2 3 4 Slot number S1 S2 Media modules used MM992 2 MM992 2SFP Device description 4 2 Product properties and device views SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 21 ...

Страница 22: ...quipment These inject power onto the Ethernet cable PD powered devices These are supplied with power via Ethernet PoE ports of SCALANCE X 300M PoE switches As a PSE the PoE switch supplies PoE capable devices with power over Ethernet The 48 V power required to supply the powered devices is generated internally on the switch no extra power supply unit is necessary The PoE switch uses alternative A ...

Страница 23: ... supply Deviations from this status are then displayed as errors faults 1 Turn on display mode A or D Display mode A is active when the DM LED is not lit Display mode D is active when the DM LED flashes yellow orange If a different display mode is active you will need to press the SET SELECT briefly possibly several times until the required display mode is active 2 Hold down the SET SELECT button ...

Страница 24: ...atus Meaning off The standby function is disabled green on The standby function is enabled The standby section is passive green flashes The standby function is enabled The standby section is active The F LED for the fault status The F LED fault provides information on the error fault status of the device While the device is starting up this LED has the following meaning LED color LED status Meanin...

Страница 25: ...ange Display mode D The L1 and L2 or L LEDs for the power supply Whereas on other devices the L1 and L2 LEDs indicate information about the power on the SCALANCE X306 1LD FE this is done by the L LED A redundant power supply for this device can be recognized by the color of the LED Meaning in display mode A B or C LED Color Status Meaning L1 L2 _ off Power supply L1 L2 lower than 17 V green on Pow...

Страница 26: ...imary voltage and the secondary voltage for both power supply units If the power supply is intact a fault occurring on a power supply unit on the secondary side can be recognized The P1 P2 LEDs for the port status The P1 P2 LEDs show information on the status of their port transmission speed mode port monitoring The meaning of these LEDs depends on the display mode DM LED Meaning in display mode A...

Страница 27: ... other words if no connection was established at the port for example no cable inserted this triggers the signaling contact and an error state results orange on The port is monitored in other words when a valid con nection exists at the port for example non permitted cable inserted this triggers the signaling contact and an error state results 4 5 C PLUG 4 5 1 Area of application and function of t...

Страница 28: ...UG inserted uses the configuration data of the C PLUG automatically when it starts up Acceptance is possible only when the data was written by a compatible device type Response to errors Inserting a C PLUG that does not contain the configuration of a compatible device type accidentally removing the C PLUG or general malfunctions of the C PLUG are signaled by the diagnostics mechanisms of the devic...

Страница 29: ...ain with the sealing screw Inserting the C PLUG B 1 Turn off the power to the device 2 Remove the sealing screw on the rear of the device with a coin or a wide blade screwdriver 3 The housing of the C PLUG has a protruding ridge on the long side position B The slot has a groove at this position Insert the C PLUG correctly oriented into the slot 4 Close the housing again with the sealing screw Devi...

Страница 30: ...Device description 4 5 C PLUG SCALANCE X 300M PoE 30 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 31: ...d safety measures at an ambient temperature higher than 50 C WARNING If the device is installed in a cabinet the inner temperature of the cabinet corresponds to the ambient temperature of the device Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1 Division 2 or Z...

Страница 32: ... point of conductors exceeds 80 C special precautions must be taken If the device is operated at ambient temperatures of between 50 C and 70 C only use cables with a maximum permitted operating temperature of at least 80 C Further notes CAUTION Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their target systems this may violate t...

Страница 33: ...described in this document and in the manual SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks https support industry siemens com cs ww en view 1172207 5 3 Installing on an S7 300 standard rail Procedure 1 Fit the top rear edge of the housing into the S7 300 standard rail 2 At the bottom the housing has two holes Use these holes to screw the housing to the standard rail 3 Secur...

Страница 34: ...ing and when subject to severe vibration The 35 mm DIN rail DIN EN 60715 does not provide adequate support in shipping or when there is severe vibration 10 g Under such conditions the device can come out of the mounting and may cause injury In such situations install the device on an S7 300 standard rail Assembling 5 4 Installation on a DIN rail SCALANCE X 300M PoE 34 Compact Operating Instruction...

Страница 35: ...ecting up Removing 1 Remove all cables connected to the X 300 2 Use a screwdriver to lever down the spring catch of the device and pull the lower part of the device away from the rail 3 Remove the device from the upper edge of the DIN rail 5 5 Wall mounting Wall mounting 1 For wall mounting use suitable mounting fittings for the wall for example for a concrete wall four plugs 6 mm diameter and 30 ...

Страница 36: ...OTICE Use only approved media modules If you use media modules that are not approved by Siemens AG there is no guarantee that the device will function according to the specification If you use unapproved media modules this can lead to the following problems Damage to the device Loss of the approvals Violation of the EMC regulations Use only approved media modules NOTICE Damage due to changing modu...

Страница 37: ...ing pairs of module slots are located one above the other in which modules can be inserted in a specific order Example of a rack device Install the first media module in slot 1 Install the third media module turned through 180 in slot 3 Other modules are then installed in slot 2 and 4 The permitted operating temperature is decided by the fully equipped device switch media module SFP transceiver Wi...

Страница 38: ...edia modules MM992 2CUC MM992 2CU and MM992 2M12 Only the following SFP transceivers may be used SFP991 1 SFP991 1LD SFP992 1 SFP992 1LD Note Slot number With modular devices the MM900 media modules must be given a slot number The slot number labels are supplied with the modular devices Installing a media module The media module is inserted with the handle pulled out When the handle is inserted th...

Страница 39: ...handle on the selected media module 3 Place the media module in the guide rails of the device slot The media module is correctly installed when it clips easi ly into the device Assembling 5 6 Installation of modular devices SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 39 ...

Страница 40: ...he module housing Turn off the device and allow the device to cool down before you remove a media module 1 Remove all connectors from the media module 2 Pull out the handle of the media module and remove the media module from the device slot 3 Secure the dummy cover Assembling 5 6 Installation of modular devices SCALANCE X 300M PoE 40 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 41: ...lation of the EMC regulations Use only approved SFPs You can insert or remove the SFP during ongoing operation Inserting an SFP Note Only the media module MM992 2SFP may be fitted with approved SFPs The SFP media module can be fitted with up to two SFPs Device Media module Variant Article number Labeling on the device Figure MM992 2SFP SFP media module 2 x 100 1000 Mbps 6GK5 992 2AS00 8AA0 9922AS ...

Страница 42: ... firmly secured 4 Plug the connecting cable into the SFP The connecting cable can be heard to lock in place and is then firmly secured Removing an SFP 1 Remove the cable connected to the SFP 2 Open the clip on the SFP and remove the SFP from the SFP media module Notice It must be possible to remove the SFP easy without using force 3 Fit a blind plug to the SFP Assembling 5 6 Installation of modula...

Страница 43: ...connected to a redundant power supply two separate power supplies both must meet these requirements Note A power source that supplies safety extra low voltage combined with a following NEC Class 2 power limiter also meets the requirements according to IEC 60950 1 EN 60950 1 VDE 0805 1 or NEC Class 2 A suitable power limiter is for example the redundancy module SITOP PSE202U NEC Class 2 article num...

Страница 44: ...les carrying electricity when the power supply is switched off or when the device is in an area without inflammable gas concentrations Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion WARNING Take measures to prevent tr...

Страница 45: ...A bad configuration or attachment of the Ethernet cables to incorrectly configured ports causes overload in the network and a breakdown in communication A device may only be inserted in a network and connected in the following situations HRP MRP The ring ports of the device being inserted in the ring were configured as ring ports The required redundancy mode must also be enabled see Configuration ...

Страница 46: ...Wiring rules When wiring use cables with the following AWG categories or cross sections Wiring rules for Screw spring loaded termi nals connectable cable cross sec tions for flexible cables without wire end ferrule 0 25 2 5 mm2 AWG 24 13 with wire end ferrule with plastic fer rule 0 25 2 5 mm2 AWG 24 13 with wire end ferrule without plastic fer rule 0 25 2 5 mm2 AWG 24 13 with TWIN wire end ferrul...

Страница 47: ... grounding cable is not supplied with the device Connect the paint free surface of the switch to the nearest grounding point using the grounding cable 6 5 24 VDC signaling contact 24 V DC signaling contact Note Supply voltage at signaling contact for XR 300M and XR 300M PoE At the signaling contact there is always a voltage of 24 VDC even if the device can be operated with 100 to 240 VAC The signa...

Страница 48: ...an be subjected to a maximum load of 100 mA safety extra low voltage SELV 24 V DC Never operate the device with AC voltage or DC voltage higher than 32 V DC CAUTION Damage to the device due to overvoltage If IE Switches X 300 are supplied over long 24 V power supply lines or networks measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines These can resul...

Страница 49: ...tage supplies the IE Switch X 300 alone The power supply is connected over a high resistance with the enclosure to allow an ungrounded set up The two power inputs are non floating Terminal block assignment 4 pin Table 6 2 Pinout of the 24 V safety extra low voltage SELV Pin number Assignment Labeling example Pin 1 L1 24 V DC Pin 2 M1 Pin 3 M2 Pin 4 L2 24 V DC Connecting 6 6 Connecting the external...

Страница 50: ...Connecting 6 6 Connecting the external 24 VDC power supply SCALANCE X 300M PoE 50 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 51: ... Installation options DIN rail 1 S7 300 standard rail Wall 1 Note When used in shipbuilding installation on a 35 mm DIN rail is not permitted In ships the 35 mm DIN rail does not provide adequate support Table 7 3 Permitted ambient conditions Storage transport temperature 40 C to 85 Max relative humidity in operation at 25 C 95 no condensation Max ambient temperature at operating altitude 2000 m o...

Страница 52: ...l 40 C to 45 Media module MM992 2SFP with pluggable transceiver SFP991 1LH SFP992 1 SFP992 1LH SFP992 1LH SFP992 1ELH SFP991 1ELH200 Horizontal 40 C to 50 Vertical 40 C to 45 MM991 2P 25 C to 40 1 Only hardware product version 02 of the media modules is permitted The hardware product version is shown on the product You can also read out this information from the device with the WBM or the CLI 2 Th...

Страница 53: ...C 18 5 VDC 30 2 VDC Table 7 7 Electrical data Power consumption and redundancy Current consumption 2 A Max power consumption incl PoE power supply of the connected PoE de vices PDs 48 W Power loss at 24 VDC 17 W Overcurrent protection of the power supply Non replaceable fuse 3 A 32 V and 5 A 125 V PoE Redundant power supply unit No Redundant power supply possible Yes Table 7 8 Electrical data Sign...

Страница 54: ...e 7 12 Pin assignment of the Ethernet ports of the SCALANCE PoE switch Pin number wire 1 Assignment for data transmis sion Assignment for power transfer PoE Alternative A MDI X Pin 1 RX V Pin 2 RX V Pin 3 TX V Pin 4 Pin 5 Pin 6 TX V Pin 7 Pin 8 1 with 4 wire industrial twisted pair cables the wires are connected to pins 1 2 3 and 6 7 3 Cable lengths Table 7 13 Permitted cable lengths copper cable ...

Страница 55: ...Plug 180 4 2 0 to 90 m IE FC Standard Cable 4 2 22 AWG with IE FC Outlet RJ 45 10 m TP cord 0 to 60 m 10 m TP cord IE FC Flexible Cable 4 2 22 AWG with IE FC Outlet RJ 45 10 m TP cord 0 to 90 m 10 m TP cord Note Permitted cable lengths fiber optic cable Fast Ethernet or gigabit The values correspond to those of the permitted MM900 media modules and SFP transceivers 7 4 Other properties Switching p...

Страница 56: ...ames per second At a frame length of At 100 Mbps At 1000 Mbps 148810 1488095 64 bytes 84459 844595 128 bytes 45290 452899 256 bytes 23496 234962 512 bytes 11973 119732 1024 bytes 9615 96154 1280 bytes 8127 81274 1518 bytes Note The following applies to IE Switches X 300 The number of IE Switches X 300 connected in a line influences the frame delay time When a frame passes through the switch this i...

Страница 57: ...must be able to process a frame length of at least 1528 bytes Jumbo Frames This value is the maximum frame length including VLAN tag of 1522 bytes plus the length of the PRP trailer of 6 bytes The following table shows the version as of which the devices are PRP compatible Technical data 7 4 Other properties SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 57 ...

Страница 58: ...Technical data 7 4 Other properties SCALANCE X 300M PoE 58 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 59: ...Dimension drawings 8 All dimensions in the drawings are in millimeters Figure 8 1 X308 2M PoE Front view SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 59 ...

Страница 60: ...Figure 8 2 X308 2M PoE Side view Dimension drawings SCALANCE X 300M PoE 60 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 61: ...Figure 8 3 X308 2M PoE Drilling template Dimension drawings SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 61 ...

Страница 62: ...Dimension drawings SCALANCE X 300M PoE 62 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 63: ...nformity The SIMATIC NET products described in these operating instructions meet the requirements and safety objectives of the following EC directives and comply with the harmonized European standards EN which are published in the official documentation of the European Union and here 2014 34 EU ATEX explosion protection directive Directive of the European Parliament and the Council of 26 February ...

Страница 64: ...mation Use of subassemblies modules in a Zone 2 Hazardous Area You will find this document here On the data medium that ships with some products Product CD product DVD SIMATIC NET Manual Collection On the Internet pages of Siemens Industry Online Support https support industry siemens com cs ww en view 78381013 The SIMATIC NET products described in these operating instructions meet the requirement...

Страница 65: ... protection n EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements ec ATEX classification II 3 G Ex ec IIC T4 Gc Certificate no DEKRA 18ATEX0025 X The products meet the requirements of the following standards EN 60079 7 Explosive atmospheres Part 7 Equipment protection through increased safety e EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements You will find ...

Страница 66: ... atmospheres Part 7 Equipment protection through increased safety e IEC 60079 0 Explosive atmospheres Part 0 Equipment General requirements You will find the current versions of the standards in the currently valid IECEx certificates Note for devices with CLASS 1 LASER Important note on products certified according to Type Examination Certificate KEMA 07ATEX0145 X as of Issue 95 DEKRA 18ATEX0025X ...

Страница 67: ... The product meets the requirements of the standards Factory Mutual Approval Standard Class Number 3611 FM Hazardous Classified Location Electrical Equipment Non Incendive Class I Division 2 Groups A B C D T4 and Non Incendive Class I Zone 2 Group IIC T4 cULus Approval for Information Technology Equipment cULus Listed I T E Underwriters Laboratories Inc complying with UL 60950 1 Information Techno...

Страница 68: ...rasian Economic Union of Russia Belarus Armenia Kazakhstan and Kyrgyzstan Declaration of conformity according to the technical regulations of the customs union TR ZU FDA and IEC marking The following devices meet the FDA and IEC requirements listed below Device CLASS 1 LASER Product 6GK5 308 2QG00 2AA2 6GK5 308 2QG10 2AA2 For modular devices you can find the marking in the operating instructions f...

Страница 69: ...Manual https support industry siemens com cs ww en view 84922825 EMC Installation Guidelines configuration manual https support industry siemens com cs ww en view 60612658 WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagne...

Страница 70: ...Approvals 9 1 Mechanical stability in operation SCALANCE X 300M PoE 70 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 71: ...ance to vibration is achieved Numerous SCALANCE devices therefore provide connection options for X coded M12 connectors Pin assignment 1 2345678 1 2 3 6 5 4 7 8 1 2 3 4 7 8 5 6 1 2 3 4 7 8 5 6 A B A Front view of M12 connector X coded according to IEC61076 2 109 B Front view of RJ 45 connector latching nose at the top with pin assignment according to EIA TIA 568B Pin M12 X coded RJ 45 according to...

Страница 72: ...Appendix A 1 Connector system M12 X coded according to IEC 61076 2 109 SCALANCE X 300M PoE 72 Compact Operating Instructions 11 2019 A5E02630810 13 ...

Страница 73: ...Glossary 8 S Safety notices for installation 31 general 11 Use in hazardous areas 11 31 43 when connecting up 43 SIMATIC NET glossary 8 SIMATIC NET manual 7 System manual 7 33 69 SCALANCE X 300M PoE Compact Operating Instructions 11 2019 A5E02630810 13 73 ...

Страница 74: ...Index SCALANCE X 300M PoE 74 Compact Operating Instructions 11 2019 A5E02630810 13 ...