![Siemens Simatic S7-1500 CPU 1512C-1 PN Скачать руководство пользователя страница 172](http://html.mh-extra.com/html/siemens/simatic-s7-1500-cpu-1512c-1-pn/simatic-s7-1500-cpu-1512c-1-pn_user-manual_1265380172.webp)
Parameter data records
B.3 Structure of a data record for output channels of the analog on-board I/O
CPU 1512C-1 PN (6ES7512-1CK01-0AB0)
172
Manual, 12/2017, A5E40898741-AA
B.3
Structure of a data record for output channels of the analog on-
board I/O
Assignment of data record and channel
The parameters for the 2 analog output channels are located in data records 64 and 65 and
are assigned as follows:
●
Data record 64 for channel 0
●
Data record 65 for channel 1
Data record structure
The figure below shows the structure of data record 64 for channel 0 as an example. The
structure is identical for channel 1. The values in byte 0 and byte 1 are fixed and must not be
changed.
You enable a parameter by setting the corresponding bit to "1".