2-1
PP7, PP17-I, PP17-II Equipment Manual
Release 06/98
Starting Up the Push Button Panel
The following section provides help regarding the configuration possibilities of
the Push Button Panel. Connection type MPI is pre-selected in the system set-
tings.
The system settings for the MPI connection are:
MPI address:
3
Baud rate:
187.5 KBaud
Data area type:
Marker byte
Memory word:
100
Configuring data block:
0
PLC address:
2
PLC type:
300 (S7-300)
Highest station address:
126
Number of MPI masters:
1
The following table provides an overview of the possibilities for modifying the
defined system settings:
Intention
Procedure
Chap-
ters
Modify MPI address
Set MPI address on Push
Button Panel
Change baud rate
Change baud rate on Push
Button Panel
Change data area type
Change data area type on
Push Button Panel
Configure Push Button Panel
properties which deviate from
dj
d
i
Set up configuring data block
in the PLC
p p
pre-adjusted system settings
Set parameter
Set the number of the config-
uring data block on the Push
Button Panel
MPI connection
2