3
3-13
PG 760 Programming Device
C79000-G7076-C761-01
3.5
Multipoint Interface (MPI/DP)
You can connect your PG 760 to a SIMATIC S7 programmable logic
controller using the floating MPI/DP interface. The MPI cable (5 m long) for
connection to SIMATIC S7 CPUs is supplied with the PG 760.
(Order No.: 6ES7901-0BF00-0AA0)
MPI/DP interface
6ES7901-0BF00-0AA0
MPI connecting cable
Figure 3-8
Connection via Multipoint Interface
Connect your PG 760 to a SIMATIC S7 programmable controller as follows:
1. Switch off the PG 760.
2. Plug the connecting cable into the MPI/DP port.
!
Caution
Risk of damage to the PG 760!
Before plugging in the cables, you must discharge your body’s electrostatic
charge by briefly touching a grounded object (ESD guideline).
Via the MPI/DP interface, you can couple your programming devices to
S
MPI networks (S7-200, S7-300 and S7-400) or
S
PROFIBUS DP networks (DP components).
The supplied MPI cable can be used for connection to MPI networks with
transmission rates up to 187.5 Kbps.
Connecting an S7
Programmable
Controller via the
MPI/DP Interface
Coupling
Installing and Operating the PG 760