3.4
SET button
Position
The "SET" button is located on the front of the device.
6(7
Figure 3-1
Position of the "SET" button
Function
With the SET button, you can display and change the set fault mask.
Setting the fault mask
Factory setting
In its delivery condition (factory default), the following settings are monitored via the message
screen:
• Link up to all ports
• Redundant power supply (L1+/M1 und L2+/M2) connected
When you turn the device on and at least one of the settings is not fulfilled, the device registers
a fault. Switch the device to the required operating mode and save these settings in the message
screen.
Changing the setting
The changed settings remain after cycling power to the device.
Different settings are made depending on how long you hold down the SET button, as described
in the following table:
3KDVH
3KDVH
3KDVH
7LPHWKHEXWWRQLVSUHVVHG
LQVHFRQGV
V
V
V
Description of the device
3.4 SET button
SCALANCE XC-100
Operating Instructions, 06/2022, C79000-G8976-C415-06
19