4.8
Mounting tensile strain relief
Required tools
• Torx screwdriver, size T10
• Cable ties
We recommend cable ties with a width of 4.8 mm. The maximum width is 7.0 mm. The
length of the cable tie is min. 60 mm.
Installation
Figure 4-6
Mounting tensile strain relief
To mount tensile strain relief on the device, follow the steps below:
1. Bring the gap in the strain relied in line with the gap in the device
①
.
2. Screw the strain relief with the supplied screw (tightening torque 0.8 Nm)
②
.
Use the specified tool for this.
3. Mount a bus adapter, see section "Mounting bus adapters (Page 52)".
4. Insert the connection plugs into the sockets intended for this on the bus adapter.
5. Use cable ties to secure the cable to the strain relief.
Removal
To remove strain relief from the device, follow the steps below:
1. Release the cable from the strain relief and pull the cable.
2. Remove the bus adapter, see section "Mounting bus adapters (Page 52)".
3. Loosen the screw connection.
4. Remove the strain relief.
Installation and removal
4.8 Mounting tensile strain relief
SCALANCE X-200
54
Operating Instructions, 11/2021, C79000-G8976-C284-15
Содержание SIMATIC NET SCALANCE X-200
Страница 8: ...Introduction SCALANCE X 200 8 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 12: ...Safety notices SCALANCE X 200 12 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 18: ...Recommendations on network security SCALANCE X 200 18 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 56: ...Installation and removal 4 9 Disassembly SCALANCE X 200 56 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 80: ...Maintenance and cleaning SCALANCE X 200 80 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 92: ...Technical specifications SCALANCE X 200 92 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 110: ...Index SCALANCE X 200 110 Operating Instructions 11 2021 C79000 G8976 C284 15 ...