Connection
6.5 Digital input/output
SCALANCE WxM763
Operating Instructions, 03/2022, C79000-G8976-C653-01
59
6.5
Digital input/output
The following devices have a digital input and output:
•
SCALANCE WAM763-1 with the article number 6GK5763-1AL00-7DA0
•
SCALANCE WUM763-1 with the article number 6GK5763-1AL00-3DA0
The digital input and output are connected using a 2-pin plug-in terminal block in each
case. Two terminal blocks ship with the device.
NOTICE
Damage due to voltage being too high or too low
The voltage at the digital input/output must not exceed 30 VDC and not fall below -30
VDC, otherwise the digital input/output will be destroyed.
Note
Interference pulse
To avoid evaluating an interference pulse, the pulse for the signal 1 (TRUE / HIGH) must
be at least 200 ms.
Wiring rules
•
To wire the digital input/output, use a copper cable of category AWG18-16 or a cable
with a cross-section of 0.75 to 1.5 mm
2
.
•
Always wire the digital input/output in pairs.
•
The maximum permissible cable length is 30 m.
You can find more information in the section "Terminals (Page 22)".
Содержание SIMATIC NET SCALANCE WxM763
Страница 8: ...Introduction SCALANCE WxM763 8 Operating Instructions 03 2022 C79000 G8976 C653 01 ...
Страница 10: ...Safety notices SCALANCE WxM763 10 Operating Instructions 03 2022 C79000 G8976 C653 01 ...
Страница 64: ...Connection 6 7 Replacing a CLP SCALANCE WxM763 64 Operating Instructions 03 2022 C79000 G8976 C653 01 ...
Страница 66: ...Maintenance and cleaning SCALANCE WxM763 66 Operating Instructions 03 2022 C79000 G8976 C653 01 ...
Страница 74: ...Technical data SCALANCE WxM763 74 Operating Instructions 03 2022 C79000 G8976 C653 01 ...
Страница 76: ...Dimension drawings SCALANCE WxM763 76 Operating Instructions 03 2022 C79000 G8976 C653 01 ...
Страница 78: ...Approvals SCALANCE WxM763 78 Operating Instructions 03 2022 C79000 G8976 C653 01 ...