Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
168
Configuration Manual, 10/2021, C79000-G8976-C475-03
The table has the following columns:
•
Select
Select the row you want to delete.
•
User Name
Shows the created users.
•
Authentication Protocol
Specify the authentication protocol for which a password will be stored.
The following settings are available:
–
None
–
MD5
–
SHA
•
Privacy Protocol
Specify the encryption protocol for which a password will be stored. This drop-down
list is only enabled when an authentication protocol has been selected.
The following settings are available:
–
None
–
DES
–
AES
•
Authentication Password
Enter the authentication password in the first input box. This password must have at
least 1 character, the maximum length is 32 characters.
Note
Length of the password
As an important measure to maximize security, we recommend that the password has
a minimum length of 6 characters and that it contains special characters,
uppercase/lowercase letters, numbers.
•
Authentication Password Confirmation
Confirm the password by repeating the entry.