Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
133
•
Schedule restart
When you click this button, a timer starts and runs backwards with the defined time.
When the timer has expired, the device restarts.
The following message is also displayed in the display area: "The automatic restart
starts in [..] minutes. Click 'Cancel scheduled restart' to cancel the restart". This
message can be seen on every WBM page until you cancel the restart or the
SCALANCE device is restarted.
Note
Unsaved configuration is lost after restart
The scheduled restart is performed after the time has elapsed without any further
message. Unsaved configuration changes are lost.
•
Cancel scheduled restart
With this button you disable the timer for the scheduled restart.
See also
Requirements for operation (Page 25)
4.4.5
Load&Save
4.4.5.1
File list
Overview of the file types
File type
Description
Config
This file contains the start configuration.
The file can be supplied with a password before download. To load the file
into the device successfully, use the specified password. You enter the
password on the WBM page "Passwords (Page 146)".
ConfigPack
ZIP file consisting of the Config, Users and LSYS file, which means the
entire configuration. Recommended for a backup of the configuration.
The file can be supplied with a password before download. To load the file
into the device successfully, use the specified password. You enter the
password on the WBM page "Passwords (Page 146)".
LicenseConditions ZIP file with the open source software license conditions.
Debug
This file contains information for Siemens Support.
It is encrypted and can be sent by e-mail to Siemens Support without any
security risk.
Firmware
The firmware is signed and encrypted. This ensures that only firmware
created by Siemens can be downloaded to the device.
Содержание SIMATIC NET SCALANCE SC-600