Technical Specifications
5
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
Use the internal fuse rating to determine the size of the external circuit breaker/fuse.
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Input Range
Power Sup-
ply Type
Terminal
Block Type
Min
Max
Internal
Fuse Rating
Maximum
Power Con-
sumption
24 VDC (Single)
13 VDC
36 VDC
10 A
62 W
48 VDC (Single)
Screw
38 VDC
72 VDC
5 A
59 W
98 VDC
300 VDC
High Volt-
age AC/DC
Screw/
Pluggable
88 VAC
264 VAC
3.15 A
66 W
5.2
Failsafe Alarm Relay Specifications
NOTICE
The alarm switching voltage must be greater than the Safety Extra Low-Voltage
(SELV) to meet safety requirements.
Parameter
Value (Resistive Load)
Maximum Switching Voltage
250 VAC
30 VDC
Rated Switching Current
2 A @ 250 VAC
2 A @ 30 VDC
Maximum Switching Capacity
150 W
500 VA
RUGGEDCOM RSG2488F
Installation Manual, 11/2019, C79000-G8976-1351-05
37