Certification
6.1.6 RoHS
6.1.6
RoHS
This device is declared by Siemens AG to meet the requirements of the following
RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain
hazardous substances in electrical and electronic equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RS940GF has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclosure
Ports
20 V/m
x
Signal Ports
± 4 kV @ 2.5 kHz
x
DC Power
Ports
± 4 kV
4
AC Power
Ports
± 4 kV
4
IEC
61000-4-4
Burst (Fast Transient)
Earth
ground Ports
± 4 kV
4
Signal Ports
± 4 kV line-to-earth,
± 2 kV line-to-line
4
DC Power
Ports
± 2 kV line-to-earth,
± 1 kV line-to-line
3
IEC
61000-4-5
Surge
AC Power
Ports
± 4 kV line-to-earth,
± 2 kV line-to-line
4
Signal Ports
10 V
3
D.C Power
Ports
10 V
3
AC Power
Ports
10 V
3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
ground Ports
10 V
3
IEC
61000-4-8
Magnetic Field
Enclosure
Ports
40 A/m continuous,
1000 A/m for 1 s
RUGGEDCOM RS940GF
Installation Manual, 01/2021, C79000-G8976-1356-04
33