![Siemens SIMATIC NET RUGGEDCOM RS400 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/siemens/simatic-net-ruggedcom-rs400/simatic-net-ruggedcom-rs400_installation-manual_383869046.webp)
Certification
6.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
IEC 61000-4-8
Magnetic Field
Enclosure Ports
40 A/m continuous,
1000 A/m for 1 s
DC Power Ports
30% for 0.1 s, 100% for 0.05 s
IEC 61000-4-29
30% for 1 period,
60% for 250 periods
IEC 61000-4-11
Voltage Dips
and Interrupts
AC Power Ports
100% for 5 periods,
100% for 50 periods
2
Signal Ports
2.5 kV common, 1 kV
differential mode at 1 MHz
3
DC Power Ports
2.5 kV common, 1 kV
differential mode at 1 MHz
3
IEC 61000-4-12
Damped
Oscillatory
AC Power Ports
2.5 kV common, 1 kV
differential mode at 1 MHz
3
Signal Ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-16 Mains Frequency
Voltage
DC Power Ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-17
Ripple on DC
Power Supply
DC Power Ports
10%
3
Signal Ports
2 kVac (Fail-Safe Relay Output)
DC Power Ports
1.5 kVDC
Dielectric
Strength
AC Power Ports
2 kVAC
Signal Ports
5 kV (Fail-Safe Relay output)
DC Power Ports
5 kV
IEC 60255-5
H.V. Impulse
AC Power Ports
5 kV
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
Note
The RUGGEDCOM RS400 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
Description
Test Levels
Enclosure Contact
±8 kV
ESD
Enclosure Air
±15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
±4 kV at 2.5 kHz
DC Power Ports
±4 kV
AC Power Ports
±4 kV
Fast Transient
Earth Ground Ports
±4 kV
Signal Ports
2.5 kV Common Mode at 1 MHz
DC Power Ports
1 kV Common and Differential Mode at 1 MHz
Oscillatory
AC Power Ports
1 kV Common and Differential Mode at 1 MHz
Signal Ports
2 kVAC
Dielectric Strength
DC Power Ports
1.5 kVDC
RUGGEDCOM RS400
Installation Manual, 01/2021, C79000-G8976-1016-11