background image

Overview
1.1 Operating System

IMPORTANT

Siemens assumes no responsibility for upgrades or changes made to the operating

system.

IMPORTANT

Each RUGGEDCOM APE1808 module supports UHS-I SD cards through its base oper-

ating system. If the operating system is changed, make sure the replacement operat-

ing system also supports this type of SD card.

Other Software/Applications

Siemens does not support any software installed on the RUGGEDCOM APE1808. This

includes, but is not limited to, software images provided by Siemens Customer Sup-

port.

Linux and SD Card Support

By default, the Linux-based version of the RUGGEDCOM APE1808 does not support

SDXC or SDUC microSD cards (i.e. microSD cards with a memory size of 32 GB or

higher).
SDXC and SDUC microSD cards use the Extended File Allocation Table (exFAT) file

system, which is not pre-installed in the Linux-based versions of the RUGGEDCOM

APE1808. For more information, refer to the 

SD Standard Overview [https://www.sd-

card.org/developers/overview/capacity]

.

Linux add-ons that provide support for exFAT are available but must be used in con-

junction with a valid license from Microsoft or a Microsoft-authorized provider. For

more information, refer to the 

Microsoft Technology Licensing Program for exFAT

[https://www.microsoft.com/en-us/legal/intellectualproperty/mtl/exfat-licensing.as-

px]

.

Windows Licensing

To run Windows® 10 Enterprise 2019 LTSC on the RUGGEDCOM APE1808, the Win-

dows® operating system must be activated after the RUGGEDCOM APE1808 module

has been installed.
For more information, refer to the product key sticker (included in the product pack-

aging) and 

 Windows® Support [https://support.microsoft.com/en-us/help/12440]

.

2

RUGGEDCOM APE1808

Configuration Manual, 11/2019, C79000-G8976-1415-03

Содержание SIMATIC NET RUGGEDCOM APE1808

Страница 1: ...Edition 11 2019 Configuration Manual SIMATIC NET Industrial Ethernet Switches RUGGEDCOM APE1808 For APE1808 APE1808W10 https www siemens com ...

Страница 2: ...Industrial Ethernet Switches RUGGEDCOM APE1808 Configuration Manual For APE1808 APE1808W10 Preface Overview 1 Configuring and Using the RUGGEDCOM APE1808 2 Frequently Asked Questions 3 11 2019 C79000 G8976 1415 03 ...

Страница 3: ... personnel are those who based on their training and experience are capable of identify ing risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufactur...

Страница 4: ...rking in Factory Default Conditions 7 1 8 2 Example RX15xx Services and WAN Networking 8 2 Configuring and Using the RUGGEDCOM APE1808 11 2 1 Logging in to RUGGEDCOM APE1808 11 2 2 Adding a User Linux Only 11 2 3 Setting the Root and User Passwords Linux Only 12 2 4 Setting the BIOS Password 12 2 5 Disabling Alternative Boot Options 13 2 6 Setting the GRUB Bootloader Password 14 2 7 Setting the Ha...

Страница 5: ...Table of Contents iv RUGGEDCOM APE1808 Configuration Manual 11 2019 C79000 G8976 1415 03 ...

Страница 6: ... other documents related to this product that may be of interest Unless indicated otherwise each document is available on the Siemens Industry On line Support SIOS https support industry siemens com website Note Documents listed are those available at the time of publication Newer versions of these documents or their associated products may be available For more informa tion visit SIOS or consult ...

Страница 7: ...o provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical support or general information contact Siemens Customer Support through any of the following ...

Страница 8: ...Preface Customer Support Ask questions or share knowledge with fellow Siemens customers and the support community RUGGEDCOM APE1808 Configuration Manual 11 2019 C79000 G8976 1415 03 vii ...

Страница 9: ...Preface Customer Support viii RUGGEDCOM APE1808 Configuration Manual 11 2019 C79000 G8976 1415 03 ...

Страница 10: ...3 4 5 6 4 1 SD Card Slot 2 Display Port 3 Gigabit Ethernet GbE Port 4 USB Ports 5 Reset Button 6 Power LED Figure 1 1 RUGGEDCOM APE1808 Module 1 1 Operating System Each RUGGEDCOM APE1808 module comes with a pre installed operating system Module Operating System APE1808 Debian Linux APE1808W10 Microsoft Windows 10 Upgrading or Changing the Operating System The operating system can be upgraded or ex...

Страница 11: ... File Allocation Table exFAT file system which is not pre installed in the Linux based versions of the RUGGEDCOM APE1808 For more information refer to the SD Standard Overview https www sd card org developers overview capacity Linux add ons that provide support for exFAT are available but must be used in con junction with a valid license from Microsoft or a Microsoft authorized provider For more i...

Страница 12: ...ce may have USB 2 0 or 3 0 interfaces SD Card Usage Limit the usage of 3 3 V SD cards and use UHS I type SD cards whenever possible 1 3 Security Recommendations To prevent unauthorized access to the module note the following security recom mendations Hardware Software Before commissioning the RUGGEDCOM APE1808 line module apply the latest security updates from Debian or from Microsoft as per stand...

Страница 13: ...gured For more information refer to Setting the GRUB Bootloader Password Page 14 Use strong passwords Avoid weak passwords such as password1 123456789 abcdefgh etc Passwords should not be re used across different usernames and systems or af ter they expire Make sure to take appropriate precautions when shipping the module beyond the boundaries of the trusted environment If SSH and SSL keys are con...

Страница 14: ...age to the device When hot swapping the RUGGEDCOM APE1808 module wait 3 seconds before re inserting the module into the RUGGEDCOM router NOTICE Whenever possible reboot the RUGGEDCOM APE1808 from the operating system in stead of requesting a reboot with the Reset button This helps to safeguard against improper shutdowns and protect data integrity Powering Down the RUGGEDCOM APE1808 To fully power ...

Страница 15: ... 2 3 4 1 Switch Fabric Data Plane 2 Line Module 10 100 1000Base TX 3 RUGGEDCOM APE1808 Module 4 Gigabit Ethernet GbE Network Interfaces Figure 1 2 A RUGGEDCOM RX15xx Device With an RUGGEDCOM APE1808 Module Installed 1 7 Default IP Addresses Based on the software platform installed on the RUGGEDCOM APE1808 the IP ad dresses for the front and or internal ports may be pre configured or set dynamicall...

Страница 16: ...ed in a RUGGEDCOM RX15xx chassis with a four port Eth ernet module in LM2 Figure 1 3 Example Configuration In the factory default condition all Ethernet interfaces on the RUGGEDCOM RX15xx router including the internal port of the RUGGEDCOM APE1808 are created as switched ports in the default VLAN When DHCP is configured in RUGGEDCOM ROX II an IPv4 subnet and a gateway IP are automatically assigned...

Страница 17: ...or much the same reason should you wish to forward traffic arriving on fe cm 1 through to the 172 16 0 0 16 network via the RUGGEDCOM APE1808 you would need to configure a route for it on the RUGGEDCOM RX15xx device and enable IP for warding from the Windows or Linux operating system Note When operating the RUGGEDCOM APE1808 in either switch or router mode the RUGGEDCOM RX15xx will issue RSTP BPDU...

Страница 18: ...le these ports must be configured as socket ports that allow incoming calls on TCP ports 5001 ser 3 1 through 5006 ser 3 6 While any address on the RX1500 control module may be used to connect the RUGGEDCOM APE1808 to these ports switch 0001 switch 0002 and dummy0 addresses are recommended In par ticular dummy0 addresses are useful when router redundancy is implemented As in the previous scenario ...

Страница 19: ...Overview 1 8 2 Example RX15xx Services and WAN Networking 10 RUGGEDCOM APE1808 Configuration Manual 11 2019 C79000 G8976 1415 03 ...

Страница 20: ...TICE Security hazard risk of unauthorized access To prevent unauthorized access to the device make sure to change the default pass word before commissioning the device Software Platform Default Username Default Password Windows 10 Enterprise 2019 LTSC There is no default username or password for Windows 10 Enter prise 2019 LTSC installations The username and password is set by the user during the ...

Страница 21: ...Phone Other Is the information correct Y n y root wheezyape 2 3 Setting the Root and User Passwords Linux Only For security reasons the default root Linux password should be changed before the module is deployed NOTICE Use strong passwords Avoid weak passwords such as password1 123456789 abcdefgh etc Changing the Root Password To change the default root password for Linux do the following 1 Login ...

Страница 22: ...ll control of all RUGGEDCOM APE1808 set tings 5 Enable Power On Password 6 Set the supervisor and power on password 7 Press F10 to save and reboot 2 5 Disabling Alternative Boot Options To prevent users with physical access to the module from logging in to the device and bypassing the bootloader password it is recommended that alternative unau thorized boot options be disabled before the module is...

Страница 23: ...C845E07E440F134D ED2537081F54 Record the password for future use in the upcoming steps 3 Using vim or nano open the file etc grub d 40_custom 4 In the file etc grub d 40_custom add the following line set superusers root 5 Add the the following line password_pbkdf2 root KEY Add the GRUB password created in Step 2 to this line For example password_pbkdf2 root grub pbkdf2 sha512 10000 380AD91E6C36BB4...

Страница 24: ... Troubleshooting the RUGGEDCOM APE1808 The following describes potential solutions for common problems Lost IP Address The simplest resolution to this problem occurs when the RUGGEDCOM APE1808 is easily reached and a monitor is attached The RUGGEDCOM APE1808 can be queried for the IP address and the configuration of the RUGGEDCOM APE1808 or command module may be changed to allow networking If the ...

Страница 25: ...Installation Manual for your RUGGEDCOM RX15xx device If power is sufficient the syslog file should be examined for irregularities during the boot The last boot may have occurred some time in the past and may no longer be recorded in the syslog If this is the case the module can be rebooted by disabling it and re enabling it The syslog will then contain enties reflecting the RUGGEDCOM APE1808 boot ...

Страница 26: ...ecover an image of the original factory settings A Siemens strongly recommends creating a backup image of the RUGGEDCOM APE1808 before it is configured If this image is available it can be easily re stored If an original backup image is not available contact Siemens Customer Support for assistance In most cases the RUGGEDCOM APE1808 module must be re turned to the factory to be re imaged This serv...

Страница 27: ...Frequently Asked Questions 18 RUGGEDCOM APE1808 Configuration Manual 11 2019 C79000 G8976 1415 03 ...

Страница 28: ...ttps www siemens com Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: