Technical Description and Installation Instructions
1-15
SIMATIC NET CP 243-2 AS-i Master
C79000-G8976-C142/02
Example of a Slave Display
From the display shown below, you can obtain the following information:
The 2nd group LED is lit, i.e. the 2nd line from the top (corresponds to 2
1
=
2
DEC
; 2. group of 5; slaves 5–9).
If the 2nd and 4th LEDs are also lit within the slave display, this means that
slaves 6 and 8 are active.
If the “B” LED is also lit, then in this example, this would mean that slaves 6B
and 8B are active.
2nd
group
LED/column 2 + 4
The intersecting
points mark slave 6
and slave 8.
Figure 1-4
Example of a Slave Display