Mounting
4.2 Installing the device with mounting brackets
SIMATIC IPC627C
24
Getting Started, 09/2011, A5E02669077-03
4.2
Installing the device with mounting brackets
Screw-mounting the brackets
Two angle brackets are included in the product package. You can attach these to the PC
enclosure using six M3 x 6 mm screws.
①
Mount the brackets onto the device using the included M3 screws with a max. insertion depth
of 5 mm (included in package).
Instructions for wall mounting
Mounting examples
Material
Hole diameter
Mounting
Concrete
8 mm diameter, 60 mm depth
Dowel: 8 mm, 50 mm
screws 4 mm, 50 mm
Plasterboard
(min. 13 mm thick)
14 mm diameter
Tilting dowel
diameter 4 mm
min. length 50 mm
Metal
(min. 2 mm thick)
5 mm diameter
Metal screws
diameter 4 mm
min. length 15 mm
WARNING
Ensure that the wall is capable of bearing four times the total weight of the device (including
the brackets and expansion modules). The total weight is approx. 7 kg.
4.3
Installing the device with the vertical mounting kit
The optional vertical mounting kit allows space-saving installation of the device.