Expanded device functions
5.1 Monitoring functions
SIMATIC IPC547E
56
Operating Instructions, 02/2014, A5E32317120-AB
5.1.1
Temperature monitoring and temperature display
The temperature is detected at critical device locations by temperature sensors. A
temperature sensor monitors the processor temperature. Other temperature sensors monitor
further critical points.
If the set temperature threshold is exceeded at a temperature sensor, the following reactions
are triggered:
●
The "TEMP" status display flashes red.
●
The device fans are running at full speed.
●
The power supply fan is controlled by the power supply itself.
●
A temperature alarm is output if the SIMATIC monitoring software is installed.
Note
When the device is operated according to instructions, no temperature error occurs.
In the event of a temperature error, check the following possible causes:
●
Ventilation openings are covered
●
Filter is heavily polluted
●
Fan has failed
●
Ambient temperature is above the permitted value
●
Output power of the power supply is exceeded
The temperature error remains stored until the monitored temperatures fall below the
temperature threshold that is set. You can reset the error message with one of the following
measures:
●
Acknowledge error message with SIMATIC IPC DiagBase or SIMATIC IPC DiagMonitor
●
Short-term disconnection of the device from the power supply
●
Shut down device
●
Restart the device
Содержание SIMATIC IPC547E
Страница 4: ...Preface SIMATIC IPC547E 4 Operating Instructions 02 2014 A5E32317120 AB ...
Страница 22: ...Overview 1 5 Status displays SIMATIC IPC547E 22 Operating Instructions 02 2014 A5E32317120 AB ...
Страница 30: ...Safety instructions 2 4 Notes on use SIMATIC IPC547E 30 Operating Instructions 02 2014 A5E32317120 AB ...
Страница 142: ...List of abbreviations SIMATIC IPC547E 142 Operating Instructions 02 2014 A5E32317120 AB ...
Страница 154: ...Index SIMATIC IPC547E 154 Operating Instructions 02 2014 A5E32317120 AB ...