background image

 

 

Legal information   

Legal information 
Warning notice system 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent 

damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert 

symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are 

graded according to the degree of danger. 

DANGER 

 

indicates that death or severe personal injury will result if proper precautions are not taken. 

 

WARNING 

 

indicates that death or severe personal injury may result if proper precautions are not taken. 

 

CAUTION 

 

with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. 

 

CAUTION 

 

without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. 

 

NOTICE 

 

indicates that an unintended result or situation can occur if the corresponding information is not taken into 

account. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will 

be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to 

property damage. 

Qualified Personnel 

The device/system may only be set up and used in conjunction with this documentation. Commissioning and 

operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes 

in this documentation qualified persons are defined as persons who are authorized to commission, ground and 

label devices, systems and circuits in accordance with established safety practices and standards. 

Proper use of Siemens products 

Note the following: 

WARNING 

 

Siemens products may only be used for the applications described in the catalog and in the relevant technical 

documentation. If products and components from other manufacturers are used, these must be recommended 

or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and 

maintenance are required to ensure that the products operate safely and without any problems. The permissible 

ambient conditions must be adhered to. The information in the relevant documentation must be observed. 

Trademarks 

All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this 

publication may be trademarks whose use by third parties for their own purposes could violate the rights of the 

owner. 

Disclaimer of Liability 

We have reviewed the contents of this publication to ensure consistency with the hardware and software 

described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the 

information in this publication is reviewed regularly and any necessary corrections are included in subsequent 

editions. 

 

 

Siemens AG 
Industry Sector 
Postfach 48 48 
90026 NÜRNBERG 
GERMANY 

 A5E02414743-01  
Ⓟ 04/2009 

Copyright © Siemens AG 2009. 
Technical data subject to change

Содержание SIMATIC IPC427C

Страница 1: ...________ Introduction 1 Safety Instructions 2 Description 3 Application planning 4 Installing mounting 5 Connecting 6 Commissioning 7 Integration into an Automation System 8 Functions 9 Expansions and Configurations 10 Maintenance and Service 11 Alarm error and system messages 12 Troubleshooting FAQs 13 Technical specifications 14 Dimension drawings 15 Detailed descriptions 16 Appendix A ESD guide...

Страница 2: ... only be performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications de...

Страница 3: ...ection components 18 3 5 3 Operator controls 19 3 5 4 Status displays 20 4 Application planning 21 4 1 Transport 21 4 2 Unpacking and checking the delivery unit 22 4 3 Ambient and Environmental Conditions 24 5 Installing mounting 25 5 1 Permitted mounting positions 25 5 2 Mounting information 27 5 3 Mounting the device 27 5 4 Mounting on DIN rails 28 5 5 Mounting with mounting brackets 30 5 6 Upri...

Страница 4: ...hout monitor and keyboard 54 10 Expansions and Configurations 55 10 1 Open the device front panel 55 10 2 Memory expansion 57 10 2 1 Installing the memory module 57 10 3 Installing PCI 104 PC 104 Plus modules 59 10 3 1 Notes on the modules 59 10 3 2 Mounting PCI 104 or PC 104 Plus modules 60 10 4 Installing Removing Compact Flash Cards 62 10 4 1 Installation options for Compact Flash cards 62 10 4...

Страница 5: ... error messages 87 13 Troubleshooting FAQs 89 13 1 General problems 89 13 2 Problems when using modules of third party manufacturers 90 14 Technical specifications 91 14 1 General specifications 91 14 2 Power requirements of the components 95 14 3 Integrated DC power supply 96 15 Dimension drawings 97 15 1 Overview of the dimensional drawings 97 15 2 Dimension drawings of the device 98 15 3 Dimens...

Страница 6: ...2 System resources used by the BIOS DOS 136 16 3 2 1 PCI Interrupt Lines 136 16 4 I O Address Areas 137 16 4 1 Overview of the internal module registers 137 16 4 2 Watchdog enable register 066h select register read write address 062h 138 16 4 3 Watchdog trigger register read only address 066h 138 16 4 4 CAN base address register write only address 066h 139 16 4 5 Output register LED 1 2 read write...

Страница 7: ... understand this manual General knowledge in the field automation control engineering is recommended Scope of validity of this document The operating instructions are valid for all supplied variations of the SIMATIC IPC427C and describe the delivery status as of May 2009 Position in the information landscape The documentation for the SIMATIC IPC427C includes the following sections SIMATIC IPC427C ...

Страница 8: ...structions Connecting Options of connecting the product and connection instructions Commissioning Commissioning the product system Integration Options of integrating the product into existing or planned system environments networks Functions Monitoring and display functions Expansions configurations Procedure for installing expansion devices memory modules Maintenance and service Replacement of ha...

Страница 9: ...please contact your service representative Repairs Only authorized personnel are permitted to repair the device WARNING Unauthorized opening of and improper repairs to the device may result in substantial damage to equipment or endanger the user System expansions Only install system expansion devices designed for this device The installation of other expansions can damage the system and violate th...

Страница 10: ... body do not open do not short circuit do not reverse polarity do not heat above 100 C dispose of correctly and protect against direct sunlight dampness and dew ESD directives Modules containing electrostatic sensitive devices ESDs can be identified by the following label Strictly follow the guidelines mentioned below when handling modules which are sensitive to ESD Always discharge your body s st...

Страница 11: ...g Instructions 04 2009 A5E02414743 01 11 Description 3 3 1 Overview The SIMATIC IPC427C provides high level industrial performance Compact design Maintenance free operation High degree of ruggedness Figure 3 1 SIMATIC IPC427C ...

Страница 12: ...he field of machine systems and switchgear cabinet engineering Measuring and controlling of process and machine data for example automated washing systems assembling machines packaging machines Operating and visualization tasks with separate display monitor solutions information terminals large scale displays in automotive production Data logging and processing for example system data logging dist...

Страница 13: ...e slots for expansion Up to 3 x PCI 104 modules or 3x PC 104 Plus module PCI bus only installed with expansion frame Graphics Integrated Intel GMA4500 graphics CRT resolution of 640x480 pixels up to 1920x1200 pixels DVI resolution of 640x480 pixels up to 1920x1200 pixels 8 512 MB graphics memory taken from main memory dynamic UMA Power supply 24 VDC 19 2 28 8 V max 4 A Conditions of use Operation ...

Страница 14: ...am local via LAN LED display 4 LEDs for displaying system status 2 of these can be programmed by the user1 Transient voltage interruption Up to 15 ms buffer time at full load Buffer memory 2 MB battery buffered SRAM1 Software Operating systems Available Without Windows Embedded Standard 2009 Windows XP Professional MUI SP3 preinstalled 2 Project specific LINUX QNX VxWorks Others on request RMOS3 V...

Страница 15: ...RA ITA SPA Default language English GER default language English Administrator Account Available Available User Account Available Available Explorer Shell Available Available Internet Explorer IE Available IE7 Available IE7 Internet Information Server IIS Available V 5 1 Available V 5 1 Terminal Services Available Available Bluetooth Available Available Wireless Network Support Available Available...

Страница 16: ...ilable DirectX V9 0c V9 0c Accessories Available Available Help files for all components Available Not available Games Available Not available Fonts 316 118 Windows XP Tour Available Not available Microsoft Silverlight Available V 1 0 Available V 1 0 NetMeeting Available V 3 1 Available V 3 1 Note Activation of HORM and creation of a Hiber File When HORM is activated the Hibernate function can be ...

Страница 17: ... 5 Design SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 17 3 5 Design 3 5 1 External Design Device components Pos Description Cover plate for Compact Flash module Connection elements Status displays ...

Страница 18: ...rrupt for 10 100 1000 Mbps PROFIBUS DP MPI CAN fieldbus PROFIBUS DP MPI interface RS 485 isolated 9 pin Cannon socket or CAN fieldbus on request COM1 Serial port RS232 9 pin Cannon connector USB strain relief fastener The USB strain relief must be fastened to the device enclosure with an oval head screw M4 thread The USB cables can be fastened to the strain relief assembly with a cable tie PE term...

Страница 19: ...controls On Off switch CAUTION The On Off switch does not disconnect the device from the supply voltage Position of on off switch Pos Description The on off switch turns off the output voltages of the power supply but not disconnect from the supply system The delivery condition is Power switch turned off ...

Страница 20: ...r programs1 L1 SF Group errors RED Can be controlled by controller program e g WinAC 1 User LED L2 OFF YELLOW GREEN Can be controlled by user programs1 L2 RUN STOP RUN STOP GREEN YELLOW Can be controlled by controller program e g WinAC 1 1You can find additional information about addressing the LEDs or the SRAM under a Windows operating system in the section Output register LED L1 L2 Example progr...

Страница 21: ... severe mechanical stress when transporting it You should always use the original packaging for shipping and transporting the device CAUTION Risk of damage to the device If you are transporting the device in extreme weather conditions with large fluctuations in temperature care must be take to ensure that no moisture forms on or in the device condensation If condensation has developed on the devic...

Страница 22: ... visible transport damage Verify that the shipment contains the complete unit and your separately ordered accessories Please inform your local dealer of any disagreements or transport damages Noting the device identification data The device can be identified uniquely with the help of these numbers in case of repairs or theft Enter the data in the following table Serial number S VP Order number of ...

Страница 23: ... Setup F2 function key under Main Hardware Options Ethernet 1 Address or Ethernet 2 Address Microsoft Windows Product Key from the Certificate of Authenticity COA The COA label is only present in pre installed Windows Embedded Standard 2009 or XP Professional and is affixed to the back of the device Figure 4 1 COA Label Windows Embedded Standard 2009 Figure 4 2 COA Label Windows XP Pro for Embedde...

Страница 24: ...nstructions The device is approved for operation in closed rooms only Avoid extreme ambient conditions Protect the device against dust moisture and heat Do not place the device in direct sunlight Ensure that the distance to other components or the sides of cabinets is at least 50 mm above and 100 mm below the device Do not cover the ventilation slots of the device Always observe the mounting posit...

Страница 25: ...e with up to 3 expansion modules max load 9 W 0 to 45 C with up to 3 expansion modules max load 9 W in RAL 0 to 50 C Operation with Compact Flash cards without expansion modules in RAL 0 to 55 C Vertical power supply at the top Operation with hard disk with up to 3 expansion modules max load 9 W 5 to 40 C With installed Compact Flash card without expansion modules 0 to 45 C Operation with CompactF...

Страница 26: ...ash card without expansion modules 0 to 45 C Operation with CompactFlash card and or SSD drive with up to 3 expansion modules max load 9 W in RAL 0 to 45 C Operation with Compact Flash cards with up to 3 expansion modules max load 9 W in RAL 0 to 50 C RAL Restricted Access Location e g installation of the unit in a lockable cabinet NOTICE The safety and installation instructions for the expansion ...

Страница 27: ...vant DIN VDE requirements or the country specific regulations when mounting in switching cabinets NOTICE Ensure that the device is classified as Open Type when using the device in the area of Industrial Control Equipment UL508 A UL508 conform enclosure is therefore a mandatory requirement for approval or operation according to UL508 5 3 Mounting the device Mounting methods SIMATIC IPC427C can be m...

Страница 28: ...ce on DIN rails Note Use of Siemens 35 mm standard mounting rail is recommended Steps for mounting on DIN rails 1 Set the device inclined on the upper DIN rail 2 Swing the device fully onto the rails until both clamps completely latch Note To ensure secure mounting on vertical mounting rails a DIN rail ground terminal should be mounted beneath the device ...

Страница 29: ...et similar to mounting with mounting brackets Ensure that the wall or ceiling can hold four times the total weight of the device including the rails and additional expansion modules Also see section Mounting with mounting brackets Page 30 Removing the device from the DIN rail Push down the device until the clamps release it Swing the device out of the rails ...

Страница 30: ...ore mounting the mounting brackets Steps for removing the mounting clamps Remove the four screws and the two mounting clamps from the back of the device Installing brackets on the device Two mounting brackets are included in the device package They can be installed on the device with four screws supplied Steps for installing the mounting brackets Install the mounting brackets on the device Note Re...

Страница 31: ...Page 99 Mounting examples Material Bore diameter Mounting Concrete 8 mm diameter 60 mm depth Dowel 8 mm diameter 50 mm length Screws 4 mm diameter 50 mm length Plasterboard min 13 mm thick 14 mm diameter Gravity toggle 4 mm diameter 50 mm length Metal min 2 mm thick 5 mm diameter Metal screws M 4 4 mm diameter 15 mm length WARNING Ensure that the wall or ceiling can hold four times the total weigh...

Страница 32: ...t mounting With the available optional vertical mounting kit you have the possibility to implement a place saving installation Mounting the vertical mounting bracket onto the device Device Screws Vertical mounting bracket Note Information on installation and operation is available in the supplement of the accessories ...

Страница 33: ...n disconnected from the power supply CAUTION Strictly adhere to the specifications for peripheral equipment Note A DVI or CRT monitor should be connected and switched on when the device boots in order for it to be correctly detected by the BIOS and the operating system The screen may otherwise remain dark NOTICE The connected or built in peripherals such as USB drives should not introduce a counte...

Страница 34: ...ll other cases IEC EN DIN EN 609501 either a current source of limited output LPS Low Power Source or a line side fuse or a line side circuit breaker is necessary The power needs to be limited to a value below 4 16 A The fuse value required Max 4 A Use the special plug supplied to connect the supply voltage Connect the PE conductors as described in the next section NOTICE The permitted cable cross...

Страница 35: ...tor cross section must not be less than 2 5 mm2 The PE terminal is needed to protect the device and ensures that interference signals generated by external power cables signal cables or cables to the I O modules are safely discharged to earth Required tool for protective earth terminal TORX T20 screwdriver Protective earth terminal Connect the PE terminal M4 thread on the device to the PE conducto...

Страница 36: ...oosening of the USB cable from the device A cable binder not included in the package is needed to use this accessory To fix the USB strain relief you will need a TORX T20 screwdriver Steps for connecting the USB strain relief 1 Fasten the USB strain relief to the device housing with an oval head screw M4 thread 2 Thread the cable tie through the comb of the USB strain relief to clamp the USB cable...

Страница 37: ...t to be correctly detected by the BIOS and the operating system during startup CAUTION Risk of damage to the device If condensation has developed wait at least 12 hours before commissioning the device NOTICE Windows Embedded Standard 2009 Read the EWF and FBWF information Two configurable write filters Enhanced Write Filter and File Based Write Filter are provided with Windows Embedded Standard 20...

Страница 38: ...Setup Utility or Press ESC go to Boot Manager 2 Wait until this message is cleared then follow the instructions on the screen NOTICE The device may not be switched off at any time during the installation process Do not change the default BIOS settings otherwise the operating system setup may become corrupted 3 Restart After you have entered all the necessary information and the operating system is...

Страница 39: ... When you work with Windows Embedded Standard always shut down the PC with the command Start Shut Down Note The Enhanced Write Filter should be enabled following the installation of Windows Embedded Standard on a CompactFlash card or SSD drive When this is enabled the device can be switched off with the power switch by disconnecting the power supply ...

Страница 40: ...s Press F2 go to Setup Utility or Press ESC go to Boot Manager 2 Wait until this message is cleared then follow the instructions on the screen NOTICE The device may not be switched off at any time during the installation process Do not change the default BIOS settings otherwise the operating system setup may become corrupted 3 Automatic restart After you have entered all necessary information and ...

Страница 41: ... Windows XP Professional Embedded Standard The Multilanguage User Interface MUI allows you to set up the Windows XP Professional Embedded Standard menus and dialogs for additional languages Default language of your Windows XP MUI installation is English and a US keyboard layout You can change the language in the Control Panel Select Start Control Panel Regional and Language Options Languages tab L...

Страница 42: ...on 1 Select and create a boot medium for installation Select a suitable boot medium for the operating system to be used in the BIOS Setup CD ROM drive Compact Flash card hard disk or USB device See Boot menu Page 126 If no boot medium is available one must be created based on the instructions provided by the respective operating system documentation For example you can use the SIMATIC PC PG Image ...

Страница 43: ... package PROFIBUS MPI The optional electrically isolated PROFIBUS interface 12 Mbps can be used to interconnect distributed field devices or for coupling to SIMATIC S7 The SOFTNET for PROFIBUS software package is required for coupling to S7 automation systems CAN CAN interface for connection to CAN field systems on request RS232 The serial port can be used for data communication via terminal appli...

Страница 44: ...Integration into an Automation System 8 1 Overview SIMATIC IPC427C 44 Operating Instructions 04 2009 A5E02414743 01 ...

Страница 45: ...e reset of the computer Operating hours meter information on the cumulative run time SIMATIC PC DiagBase software With the SIMATIC PC DiagBase software included in product package you can use these functions for local monitoring You can use the DiagBase Management Explorer application for general monitoring or DiagBase Alarm Manager for notification of individual alarms Additional information on t...

Страница 46: ...AM module and the motherboard around the DVI VGA socket If one of the three configured temperature values is exceeded CPU 100 C RAM 95 C motherboard 95 C the following fault reaction is triggered Reaction Option The DiagBase or DiagMonitor software is enabled None The temperature error is retained in memory until temperatures have fallen below the thresholds and it is reset by one of the following...

Страница 47: ...t triggered again within the set time the following reactions will be triggered Reaction Option Switch watchdog LED to red None Trigger a PC reset Configurable Enabling the DiagBase or DiagMonitor software None Note If the desired device reset is not performed go the Advanced menu of the BIOS Setup and set the SafeCard functions to Enabled Contact Customer Support for a detailed description of the...

Страница 48: ...ith Compact Flash cards CAUTION Activate only one write filter per partition otherwise you may incur data loss Both EWF and FBWF are preinstalled in the SIMATIC IPC images Ensure that only one write filter is enabled on a partition otherwise you may incur data loss Note The Enhanced Write Filter is disabled by default for Windows Embedded Standard 2009 After the operating system has been set up yo...

Страница 49: ...entral time management and with activated EWF set the clock forward or backward by one hour in the daylight saving time or standard time period each time the system boots The reason for this behavior is that Windows Embedded Standard 2009 has a registry entry that detects if the clock has been adjusted for daylight saving time Since this file is also protected against modification by the EWF the m...

Страница 50: ...enable FBWF the folders C FBWF and D FBWF are authorized for writing by default Comparison between EWF and FBWF You should prefer FBWF because it is more flexible in its configuration and allows immediate writing without rebooting If you use HORM or compressed NTFS EWF is indispensable CAUTION Activate only one write filter per partition otherwise you may incur data loss Both EWF and FBWF are prei...

Страница 51: ...ble Write to protected files fbwfmgr commit c Test txt Adding removing elements in the exception list Add file fbwfmgr addexclusion C Test txt Add folder fbwfmgr addexclusion C Test folder Remove file fbwfmgr removeexclusion C Test txt Remove folder fbwfmgr removeexclusion C Test folder Call up the help function fbwfmgr For detailed instructions on FBWF go to http msdn microsoft com en us library ...

Страница 52: ...ms this is indicated by the DC FAIL signal Enough time is provided for copying data to the buffered RAM that 256 KB can be saved with a full configuration A maximum 2048 Kb memory window is displayed via a PCI address register The base address is initialized by the BIOS A corresponding function is implemented there for using the CMOS RAM under WinAC RTX NOTICE If replacement of the battery takes l...

Страница 53: ...nstalled buffer battery has a service life of at least 5 years The status can be checked with two tier battery monitoring The information can be read from an I O register and evaluated When the first warning level is reached the remaining service life of the battery for buffering CMOS data and buffered SRAM is at least 1 month ...

Страница 54: ...he device can be operated without a monitor and keyboard The device startup is guaranteed without these peripherals A USB keyboard and mouse and an analog CRT monitor can be later connected for diagnostics A digital DVI monitor can only be subsequently activated when the Windows Embedded Standard 2009 or Windows XP Professional operating system has fully booted ...

Страница 55: ...ry and expansion card modules CAUTION The device contains electronic components which may be destroyed by electrostatic charge You therefore need to take precautionary measures before you open the device Refer to the ESD guidelines on handling electrostatically sensitive components under ESD Guidelines Page 147 Tools Cover and top cover plate Torx T8 Hard disk mounting Torx T10 Protective earth te...

Страница 56: ...Configurations 10 1 Open the device front panel SIMATIC IPC427C 56 Operating Instructions 04 2009 A5E02414743 01 Open the device Steps in opening the device front panel 1 Remove the six screws 2 Remove the front panel ...

Страница 57: ...ing system and applications Note We recommend using the original spare parts for memory configuration Preparation Disconnect the device from the power supply CAUTION The electronic components on the PCBs are highly sensitive to electrostatic discharge Always take appropriate precautionary measures when handling these components Refer to the ESD directives on handling electrostatically sensitive co...

Страница 58: ... install a memory module 1 Set the memory module in the mount tilting forward 2 Carefully push the memory module back into the heat sink until it fully engages 3 Close the device Display of the current memory configuration The new memory configuration is detected automatically System RAM Extended RAM and Cache SRAM are displayed during device startup ...

Страница 59: ...ules PCI compatible 120 pin plug PC 104 Plus modules that use only the 120 pin plug PCI bus Note The necessary expansion frames for mounting these modules can be ordered as a six pack with order number 6AG4070 0BA00 0XA0 via the A D online ordering system http www siemens com automation mall NOTICE When expanding the device with PCI 104 PC 104 Plus modules adhere to the safety and mounting regulat...

Страница 60: ...on frame If the PCI 104 or PC 104 Plus module features external ports you can use these blinding plates to mount the connectors You can also use a slot plate with existing connector perforations You can find required dimensions in the section Dimension drawing of the blanking plate Page 103 CAUTION The electronic components on the PCBs are highly sensitive to electrostatic discharge Always take ap...

Страница 61: ...Mount the front panel on the expansion frame Mounting additional PCI 104 or PC 104 Plus modules The device can be equipped with a maximum of PCI 104 or PC 104 Plus modules An additional expansion frame is required for each module Follow the mounting procedure described in the previous section steps 2 to 4 Configuring installing a PCI 104 or PC 104 Plus module You may need to make settings in the B...

Страница 62: ...ash cards Memory expansion options The device features an accessible slot for Compact Flash cards types I II As an alternative to a hard disk you can optionally order a fixed mounted inaccessible Compact Flash card drive Only use SIMATIC PC Compact Flash cards for industrial application Note Only SIMATIC PC CompactFlash cards with product version number 02 ES 02 can be used for this device Figure ...

Страница 63: ...m the power supply CAUTION The electronic components on the PCBs are highly sensitive to electrostatic discharge Always take appropriate precautionary measures when handling these components Refer to the ESD directives on handling electrostatically sensitive components ESD Guidelines Page 147 Opening the module receptacle Steps for opening the module receptacle Turn the cover plate of the module r...

Страница 64: ...card 1 Open the module receptacle 2 Insert the CompactFlash card with the connector facing in until it locks into place 3 Close the module receptacle again Note The Compact Flash slot is coded against reversed insertion Insert it so that its upper side label side is facing the front panel of the device CAUTION If the Compact Flash card meets resistance flip it over Never insert the CompactFlash ca...

Страница 65: ...sh Cards SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 65 Removing the Compact Flash card Steps for removing a Compact Flash card 1 Open the module receptacle 2 Press the eject button and remove the CompactFlash card 3 Close the module receptacle again ...

Страница 66: ...3 01 10 4 3 Installing removing a built in Compact Flash card Steps for removing a built in Compact Flash card 1 Remove the four screws of the cover plate and remove it 2 Press the eject button and carefully remove the CompactFlash card from the holder 3 Fasten the cover plate again To install carry out the above steps in reverse order ...

Страница 67: ...the safety requirements and regulations on RF suppression Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed If you install or exchange system expansions and damage your device the warranty becomes void NOTICE Check the ESD Guidelines Page 147 Limitation of Liability All specifications and approvals are only valid w...

Страница 68: ... Torx T10 hard disk mounting Torx T20 Protective earth terminal Hexagon head 5mm spacing bolts PC 104 11 1 2 Preventive maintenance To maintain high system availability we recommend the preventative exchange of those PC components that are subject to wear The table below indicates the intervals for this exchange Component Exchange interval Hard disk 3 years CMOS backup battery 5 years ...

Страница 69: ...d size TORX T8 and T10 screwdrivers to mount the hard disk and a 5mm Allen wrench for installing removing PC 104 modules You will need a TORX T20 screwdriver to loosen the protective earth terminal Preparation 1 Disconnect the device from the power supply 2 Unplug all peripherals mouse keyboard monitor for example from the device Removing drives NOTICE Check the ESD Guidelines Page 147 How to remo...

Страница 70: ... Operating Instructions 04 2009 A5E02414743 01 How to remove a drive 2 Remove the four screws holding the drive to the back of the enclosure 3 Carefully remove the drive from the enclosure 4 Take the drive out of the holder Installing a drive Carry out the described tasks in the reverse order ...

Страница 71: ...or with a type recommended by the manufacturer Order No A5E00331143 Disposal CAUTION Depleted batteries must be disposed of in accordance with local regulations Preparation Note The configuration data and contents of the SRAM in the device are buffered for at least 30 seconds 1 Write down the current settings of the BIOS setup or save the settings as a user profile in the Exit menu Page 131 of the...

Страница 72: ...pen the battery compartment 2 Remove the battery holder 3 Pull out the battery plug 4 Take the old battery out of the holder 5 Place a new battery in the holder and reconnect the battery plug 6 Close the battery compartment Reconfiguring the BIOS Setup If the battery replacement takes longer than 30 seconds the configuration data of the device will be lost You will have to reconfigure the BIOS set...

Страница 73: ... software becomes corrupt for any reason you can reinstall it from the Restore CD DVD The Restore CD DVD contains an image file for the hard disk or CF card with the original software operating system with installed hardware drivers Note You require a USB keyboard and a USB CD ROM drive to reinstall the operating system Before performing the new installation you should check the date and time set ...

Страница 74: ...er settings and all authorizations or license keys on drive C will be lost in the process All data on drive C of your hard disk drive will be deleted Setup formats the hard disk partition and reinstalls the original factory software When you select the Restore entire hard disk option ALL the data user settings and authorizations or license keys will be lost on the hard disk NOTICE When using devic...

Страница 75: ...ith the Exit Saving Changes entry 5 Follow the on screen instructions CAUTION All existing data programs user settings and authorizations or license keys will be deleted from the hard disk and are therefore lost Note The Legacy USB Support option has to be set to Enabled in the Advanced menu of the BIOS so that the device can address a USB CD ROM drive ...

Страница 76: ...d drivers and is included in the Windows XP Professional variant Setting up the operating system with the Recovery CD The recovery CD contains the tools required to set up the hard drive SSD as well as the Windows XP Professional operating system After the required data have been copied to the hard disk SSD you can run Windows XP Professional Setup to install the operating system The Recovery CD i...

Страница 77: ...l be lost in this case The system drive on the hard disk will be completely deleted and reformatted and the original factory software will be copied to it When you select the Restore entire system drive option ALL data user settings and authorizations or license keys on the system drive will be lost together with all partitions Restoring the factory state To restore the factory state proceed as fo...

Страница 78: ...ional Embedded Standard menus and dialogs for additional languages Default language of your Windows XP Professional Embedded Standard MUI installation is English and a US keyboard layout You can change the language in the Control Panel Select Start Control Panel Regional and Language Options Languages tab Language used in menus and dialogs field For the Regional and Language Options set the defaul...

Страница 79: ...displayed when initialization is completed 2 Follow the on screen instructions until the Windows XP Professional Setup window opens Partition setup After you have installed a new hard disk or SSD or if partitions are faulty or when you wish to change the partitioning on your hard disk you need to create or reconfigure partitions on the hard disk CAUTION When you delete or create partitions or logi...

Страница 80: ...ging and integrating Windows in networks or multi user environments Setting up the language selection for Windows XP Professional The Multilanguage User Interface MUI allows you to set up the Windows XP Professional menus and dialogs for additional languages To install the MUI start the program MUISETUP EXE in the folder CD_DRIVE MUI of the MUI english Recovery CD DVD or in root folder of the MUI ...

Страница 81: ...to partitioning formatting the actual Compact Flash capacity does not correspond to the memory size specified on the Compact Flash Partitioning the hard disk The following partitions are configured in the factory state of the hard disk with Windows Embedded Standard 2009 Partition Name Size File system 1 Partition SYSTEM 25 GB NTFS not compressed 2 Partition DATA Remainder NTFS not compressed Part...

Страница 82: ... includes the following partitions Partition Name Size File system 1 Partition SYSTEM 25 GB NTFS not compressed 2 Partition DATA Remainder NTFS not compressed Partitioning the SSD drive The following partitions are configured in the factory state of the SSD drive with Windows XP Professional Partition Name Size File system 1 Partition SYSTEM 15 GB NTFS not compressed 2 Partition DATA Remainder NTF...

Страница 83: ...VD The required files are in the folder Drivers_WES Disable the Enhanced Write Filter before installing drivers and enable it again when you are finished 11 4 2 Installing drivers and software NOTICE Before you install new drivers or updates for multilingual operating systems MUI versions reset the regional settings for menus and dialogs and the default language to US English Install the drivers a...

Страница 84: ...g application programs and drivers A USB drive has to be connected to install the software from a CD and or floppy disk under Windows Embedded Standard 2009 Windows XP Professional Drivers for USB floppy disk and CD ROM drives are included in Windows Embedded Standard 2009 Windows XP Professional and do not have to be installed from other sources For information about installation of SIMATIC softw...

Страница 85: ...3 Performing a BIOS update Download from BIOS update Check regularly if updates are available for download to your device You can find the downloads in the Internet http www siemens com asis in the Support tab under Tools Downloads Using the global search function you can then also search for any downloads you require ...

Страница 86: ... recommend the software tool SIMATIC PC PG Image Creator as of V3 0 This tool provides comfortable and efficient functions for backup and restoring the full content of Compact Flash cards of HDDs and of individual partitions images The Image Creator only supports the burning of DVD media The software is available at the Siemens A D online ordering system http www siemens com automation mall For de...

Страница 87: ...errors In this startup phase the graphics controller is initialized and any error messages are output to the screen The error messages output by system BIOS are listed below For information on error messages output by the operating system or application programs refer to the corresponding manuals On screen error messages On screen error message Meaning tip Operating system not found Possible cause...

Страница 88: ...Alarm error and system messages 12 1 Boot error messages SIMATIC IPC427C 88 Operating Instructions 04 2009 A5E02414743 01 ...

Страница 89: ...nical support team The mouse driver is not loaded Check whether the mouse driver is properly installed and present when you start the application program For more detailed information refer to the manuals for the mouse or application programs Check whether the mouse cord is properly connected to the system unit If you use an adapter or extension on the mouse cable also check the connectors The mou...

Страница 90: ...chnical support team If the computer configuration has changed restore the original factory settings Remove all third party modules then restart the PC If the error no longer occurs the third party module was the cause of the fault Replace this module with a Siemens module or contact the module supplier The PC crashes during startup I O addresses are assigned twice Hardware interrupts and or DMA c...

Страница 91: ... CISPR22 2004 Class B FCC Class A Noise immunity Mains borne disturbance variables on supply lines 2 kV to IEC 61000 4 4 Burst 1 kV to IEC 61000 4 5 surge symmetric 2 kV to IEC 61000 4 5 Surge asymmetric Noise immunity on signal lines 1 kV to IEC 61000 4 4 Burst Length 3 m 2 kV to IEC 61000 4 4 Burst length 3 m 2 kV to IEC 61000 4 5 Surge length 30 m Immunity to discharges of static electricity 6 ...

Страница 92: ...ith hard disk with up to 3 expansion modules max load 9 W 5 to 40 C Operation with CompactFlash card Without expansion modules 0 to 45 C Operation with CompactFlash card and or SSD drive with up to 3 expansion modules max load 9 W in RAL 0 to 45 C Operation with CompactFlash card with up to 3 expansion modules max load 9 W in RAL 0 to 50 C Horizontal mounting position Operation with CompactFlash c...

Страница 93: ...2 6 ms Special Features Quality assurance acc to ISO 9001 Motherboard Processor Intel Celeron M 1 2 GHz 1 MB SLC or Intel Pentium Core 2 Solo 1 2 GHz 3 MB SLC or Intel Pentium Core 2 Duo 1 2 GHz 3 MB SLC Front Side Bus 800 MHz Main memory SO DIMM modules 512 1024 2048 4096 MB DDR3 SDRAM Buffer memory 2 MB SRAM 256 KB of this can be backed up in the buffer time of the power supply under full load F...

Страница 94: ... DP slave DP V0 DP V1 with SOFTNET DP slave Ethernet 2x Ethernet ports RJ45 Intel 82574L 10 100 1000 Mbps isolated Teaming capable CAN on request Philips SJA1000 Status displays on the device PWR GREEN Indicates correct supply voltage of 3 3 V 5 V and 12 V from the integrated power unit OFF Watchdog disabled GREEN Watchdog enabled monitoring time not expire WD RED Watchdog enabled monitoring time ...

Страница 95: ...mponents Auxiliary components Maximum permitted power consumption Max total power 5 V 3 3 V 12 V 12 V USB device High current 500 mA 10 W for all USB devices Per slot 1 5 A 1 5 A 0 3 A 0 2 A PC 104 modules Total 2 A 2 A 0 5 A 0 5 A 9 W for the whole device 1 The total load for PCI 104 and USB expansion is max 15W NOTICE Device can overheat For thermal reasons a 3 watt power loss per PCI 104 slot s...

Страница 96: ...ly components and the IPC427C device Note Inrush current A minimum of 4 5 A inrush current for 15 ms is required for starting the IPC427C The peak value of the startup current depends on the input voltage and the impedance of the 24V source Peak values of more than 4 5 A are possible This will not inhibit the operation of the IPC427C Typical power consumption Current consumption Power consumption ...

Страница 97: ...ings Dimension drawings of the device Page 98 Dimension drawings of the device with mounting brackets Page 99 Dimensional drawings of the device with vertical mounting angles Page 101 Dimensional drawings of the device with expansion frames Page 102 Dimension drawing of the blanking plate Page 103 Note The dimensions are always given in in mm and inch above Millimeter below Inch ...

Страница 98: ...rawings of the device SIMATIC IPC427C 98 Operating Instructions 04 2009 A5E02414743 01 15 2 Dimension drawings of the device Figure 15 1 Dimensional drawing of the device Front view Figure 15 2 Dimensional drawing of the device Side view ...

Страница 99: ...e device with mounting brackets SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 99 15 3 Dimension drawings of the device with mounting brackets Figure 15 3 Dimensional drawing of the device with mounting brackets Front view and top view ...

Страница 100: ...rawings 15 3 Dimension drawings of the device with mounting brackets SIMATIC IPC427C 100 Operating Instructions 04 2009 A5E02414743 01 Figure 15 4 Dimensional drawing of the device with mounting brackets Side view ...

Страница 101: ... device with vertical mounting angles SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 101 15 4 Dimensional drawings of the device with vertical mounting angles Figure 15 5 Dimensional drawings of the device with vertical mounting brackets ...

Страница 102: ...awings of the device with expansion frames SIMATIC IPC427C 102 Operating Instructions 04 2009 A5E02414743 01 15 5 Dimensional drawings of the device with expansion frames Figure 15 6 Dimensional drawings of the device with expansion frames ...

Страница 103: ...wings 15 6 Dimension drawing of the blanking plate SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 103 15 6 Dimension drawing of the blanking plate Figure 15 7 Dimensional drawing of the blinding plate ...

Страница 104: ...Dimension drawings 15 6 Dimension drawing of the blanking plate SIMATIC IPC427C 104 Operating Instructions 04 2009 A5E02414743 01 ...

Страница 105: ...he basic components of the device are the motherboard with processor chipset one slot for a RAM module internal and external ports a DC DC converter for the power supply of the device Figure 16 1 Internal layout of the device Slot for a memory module Motherboard Slot for up to three PCI 104 or PC 104 Plus modules DC DC converter Slot for Compact Flash card ...

Страница 106: ...e motherboard Component port Description Parameters Chipset Intel GM45 ICH 9m BIOS Insyde H20 CPU Intel Celeron M Inter Pentium Core 2 Solo Intel Pentium Core 2 Duo 1 2 GHz 1 MB SLC 1 2 GHz 3 MB SLC 1 2 GHz 3 MB SLC Memory DDR 3 SO DIMM module 512 MB 1024 MB 2048 MB 4096 MB Graphics Intel GMA4500 8 512 MB graphics memory taken dynamic from RAM ...

Страница 107: ...USB 2 0 PROFIBUS MPI DP12 optional external 9 pin female CAN optional external 9 pin female CAN Ethernet external 2 x RJ45 10 100 1000 Mbps DVI I external DVI I standard socket 16 1 3 2 COM1 2 Serial port COM1 9 pin plug or COM2 optional Pin no Short description Description 1 DCD Data carrier detect I 2 RxD Received data I 3 TxD Transmitted data O 4 DTR Data terminal ready O 5 GND Ground 6 DSR Dat...

Страница 108: ...a1 DVI data channel O 10 TMDS Data1 DVI data channel O 11 TMDS Data1 3 shield Cable shield 12 NC 13 NC 14 5V power VCC 5V power for DCC O 15 Ground return for 5V Hsync and Vsync GND Analog ground 16 Hot Plug Detect 17 TMDS data 0 DVI data channel O 18 TMDS data 0 DVI data channel O 19 TMDS Data0 5 shield Cable shield 20 NC 21 NC 22 TMDS clock shield Cable shield 23 TMDS clock DVI clock channel O 2...

Страница 109: ...put output 5 BI_DC Bi directional data C Input output 6 BI_DB Bi directional data B Input output 7 BI_DD Bi directional data D Input output 8 BI_DD Bi directional data D Input output S Shield LED 1 Off 10 Mbps Lit in green 100 Mbps Lit in orange 1000 Mbps LED 2 Lit Active connection to a hub for example Flashing Activity 16 1 3 5 USB USB port 4 channel high current Pin no Short description Descrip...

Страница 110: ... on PLC transmitter O 5 GND Ground isolated 6 P5V_dp_fused 5 V fused isolated 7 NC Not connected 8 LTG_A Data line I O 9 RTS_PG PG Request to send O 16 1 3 7 CAN bus CAN bus port 9 pin socket Pin no Short description Description 1 Reserved 2 CAN_L CAN bus signal L active 3 CAN_GND CAN station ground 4 Reserved 5 Reserved 6 Reserved 7 CAN H CAN bus signal H active 8 Reserved 9 Reserved NOTICE The p...

Страница 111: ...elect 1 output 34 IORD I O read output 35 IOWR I O write output 20 19 18 A0 A2 Address bit 0 2 output 17 16 15 14 12 11 10 8 A3 A10 Address bit 3 10 output to ground 21 22 23 2 3 4 5 6 47 48 49 27 28 29 30 31 D0 D15 Data bits 0 15 in out 37 INTRQ Interrupt request input 9 OE ATA SEL Enables True IDE mode 24 IOCS16 I O chip select 16 input 39 CSEL Cable select output 42 IORDY I O ready input 46 PDI...

Страница 112: ...D10 M66EN 7 AD14 AD13 GND AD12 8 3 3V C BE1 AD15 3 3V 9 SERR GND PAR 10 GND PERR 3 3V 11 STOP 3 3V LOCK GND 12 3 3V TRDY GND DEVSEL 13 FRAME GND IRDY 3 3V 14 GND AD16 3 3V C BE2 15 AD18 3 3V AD17 GND 16 AD21 AD20 GND AD19 17 3 3V AD23 AD22 3 3V 18 IDSEL0 AD28 GND IDSEL1 AD29 IDSEL2 AD30 19 AD24 C BE3 VI O IDSEL3 AD31 20 GND AD26 AD25 GND 21 AD29 5V AD28 AD27 22 5V AD30 GND AD31 23 REQ0 GND REQ1 VI...

Страница 113: ...AM of the device SETUP can be used to define the hardware configuration for example the hard disk type and system properties SETUP is also used to set the time and date of the realtime clock Changing the device configuration Your device configuration is preset for operating with the included software You should only change the default values if you have modified the technical configuration your de...

Страница 114: ... the figures shown the default settings differ based on the device versions With the default setting of your device the display shown below appears following power on for example On completion of the POST the BIOS gives you the opportunity of starting the SETUP program The following message appears on the screen PRESS F2 go to Setup Utility or Press ESC go to Boot Manager 2 Press F2 key as long as...

Страница 115: ... 01 115 16 2 3 BIOS Setup menus The various menus and submenus are listed on the next pages You can obtain information on the selected SETUP item from the Item specific help part of the respective menu Figure 16 2 BIOS SETUP menu example Header Help window Menu bar Command line Selectable submenu ...

Страница 116: ...ins information for operator input The following figures represent examples of specific device configurations The screen content may deviate slightly depending on the equipment actually supplied You can move between the menu forms using the cursor keys left and right Menu Description Main System functions are set here Advanced An extended system configuration can be set here Security Security func...

Страница 117: ...onfiguration boxes by means of the up and down cursor keys Field Meaning System Time For viewing and setting the current time System Date For viewing and setting the current date by submenus Serial ATA Port 0 Type of installed drives Serial ATA Port 1 Type of installed drives Boot options Used for setting the boot options Keyboard Features Used for setting the keyboard interface Numlock Hardware O...

Страница 118: ...g Hour Minute Second and for the date Month Day Year You can navigate through the entries within the date and time fields for example from hour to minute using the Enter key Serial ATA Port 0 Serial ATA Port 1 Figure 16 4 Serial ATA Port 0 submenu example Fast PIO Ultra DMA ATA 33 Ultra DMA ATA 66 Transfer Mode Ultra DMA ATA 100 This field shows the transmission speed of the interface The displaye...

Страница 119: ...ped if an error is detected during booting you must press F1 to acknowledge Never halt on errors Booting continues if errors occur Halt on all errors Booting is stopped if an error is detected All without keyboard Booting is stopped if any error except a keyboard error occurs POST errors All without kb smart Stop at any error but not with a keyboard or S M A R T storage media error Diagnostic scre...

Страница 120: ...riptions 16 2 BIOS Setup SIMATIC IPC427C 120 Operating Instructions 04 2009 A5E02414743 01 Keyboard Features submenu Figure 16 6 Keyboard Features submenu On Numlock Off Switches Numlock on or off following power on ...

Страница 121: ...isabled The Ethernet port on the motherboard is disabled Ethernet 1 2 Address Shows the individual Ethernet address Enabled Booting via a connected LAN is possible Ethernet 1 2 Remote Boot Disabled Booting via LAN is not possible Enabled Dual view DVI CRT is available via the DVI I socket Dual view DVI CRT Disabled Only one monitor can be enabled via the DVI VGA socket Note The second Ethernet int...

Страница 122: ...ooting via USB media is not possible but USB keyboard and USB mouse work Legacy USB support Enabled Enables Legacy Universal Serial Bus support Booting via USB media is possible and the USB keyboard and USB mouse work The USB Boot function must be enabled to allow booting from a USB device or if the system is to be operated without USB support with a USB keyboard or mouse Enabled Watchdog reset is...

Страница 123: ...1 123 IO Device Configuration submenu Figure 16 9 IO Device Configuration submenu Disabled COM 1 or COM 2 is always disabled Auto BIOS switches on the COM Resources are assigned in the OS per reconfiguration Internal COM 1 COM 2 Enabled COM 1 or COM 2 is always enabled BIOS assigns resources to COM ...

Страница 124: ... or enables the SATA controller Enhanced Serial ATA Ports 0 1 work in Legacy Mode Serial ATA Ports 4 5 work in Native IDE Mode Native PCI Serial ATA Ports 0 1 4 5 work in Native IDE Mode AHCI Serial ATA Ports 0 1 work in AHCI Mode only relevant for IPC427C SATA Controller mode AHCI OpRom Support Serial ATA Ports 0 1 4 5 work in AHCI Mode with the ROM support option setting for Panel PC not relevan...

Страница 125: ...s can be changed by the user including the user password User password Not installed The password is disabled Set Supervisor Password This field opens the password input dialog Authorized logged on users can change the supervisor password or delete and deactivate it by pressing Return Enabled Password must be entered to boot Power on password Disabled Password must be entered to access BIOS Setup ...

Страница 126: ...tailed descriptions 16 2 BIOS Setup SIMATIC IPC427C 126 Operating Instructions 04 2009 A5E02414743 01 16 2 7 Boot menu This menu allows you to assign a priority for the boot devices Figure 16 12 Boot menu ...

Страница 127: ...ed descriptions 16 2 BIOS Setup SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 127 Legacy Specifies the boot sequence for boot devices with Legacy operating systems Figure 16 13 Legacy submenu ...

Страница 128: ...ructions 04 2009 A5E02414743 01 Figure 16 14 Boot Type Order field This screen shows all possible legacy boot types The boot type with highest boot priority is shown at the top To change the sequence Select the boot source with the keys move to the desired position with or ...

Страница 129: ...ailed descriptions 16 2 BIOS Setup SIMATIC IPC427C Operating Instructions 04 2009 A5E02414743 01 129 Note You can open the Boot menu and select the boot volume by pressing the ESC key during system startup ...

Страница 130: ... 2 BIOS Setup SIMATIC IPC427C 130 Operating Instructions 04 2009 A5E02414743 01 16 2 8 Version menu Keep this information at hand if customer support has technical questions about your system Figure 16 15 Version menu example ...

Страница 131: ...th the new parameters Exit Discarding Changes All changes are discarded and the system is restarted with the old parameters Load Setup Defaults The default values are loaded Discard Changes All changes are discarded Save Changes All changes are saved Standard The BIOS settings are backed up to buffered CMOS User The BIOS settings are saved in the non volatile FLASH memory Profiles Manufacturer Thi...

Страница 132: ...d keep the pages in a safe place once you made your entries BIOS Setup default settings System parameters Defaults Custom entries Main System Time hh mm ss System Date MM DD YYYY Serial ATA Port 0 Serial ATA Port 1 Type 32 bit I O Block Mode Transfer Mode Security Mode Boot options Quick Boot Mode Enabled POST errors All without keyboard Diagnostic screen Enabled Keyboard Features Numlock On Hardw...

Страница 133: ...with models with CAN bus Advanced HPET HPET support Enabled Legacy USB support Enabled SafeCard functions Enabled IO device configuration Internal COM 1 Auto Internal COM 2 Auto SATA Configuration SATA Controller Enabled SATA Controller mode Enhanced Security Supervisor Password Not installed User password Not installed Set Supervisor Password Power on password User Access Level Set User Password ...

Страница 134: ...ons 04 2009 A5E02414743 01 Version SIMATIC PC IPC427C PROFIBUS BIOS Version V12 01 xx BIOS Number A5E02316088 ES0xx InsideH20 Version Montevina 03 56 37 20xx MPI DP Firmware ID xx FPGA Revision ID xx Processor Type Intel Core 2 Duo CPU U9300 1 20GHz CPU ID 00676 Code Revision 0C ...

Страница 135: ...re addresses memory configuration allocation of interrupts DMA channels are assigned dynamically by the Windows OS depending on the hardware configuration drivers and connected external devices You can view the current configuration of system resources or possible conflicts with the following operating systems Windows Embedded Standard 2009 Start Run In the Open dialog enter msinfo32and confirm wi...

Страница 136: ...SA exclusive IRQ2 Interrupt controller 2 ISA exclusive IRQ3 Reserved for Com Port 2 COM2 ISA exclusive COM2 IRQ4 Com Port 1 COM1 ISA exclusive IRQ5 Free IRQ6 Reserved IRQ7 Free IRQ8 Realtime clock HPET ISA exclusive IRQ9 ACPI SCI system control interrupt IRQ10 CAN optional or free ISA exclusive CAN IRQ11 Free IRQ12 PS 2 mouse controller emulation ISA exclusive IRQ13 Coprocessor ISA exclusive IRQ14...

Страница 137: ...rs The following addresses are used for the internal registers Addresses Input output unit I O 062h Watchdog enable register 066h select register Page 138 Watchdog trigger register Watchdog enable register bit 2 0 Page 138 I O 066h CAN base address register Watchdog enable register bit 2 1 Page 139 I O 404Eh 404Fh Output register LED 1 2 and SF LED RUN STOP LED Page 140 I O 50Fh Battery status reg...

Страница 138: ...selection 0 066h is Watchdog trigger register 1 066h is CAN base address register Scaler watchdog time Normal Macro 0 0 0 94 ms 2 s default 0 0 1 210 ms 4 s 0 1 0 340 ms 6 s 0 1 1 460 ms 8 s 1 0 0 590 ms 16 s 1 0 1 710 ms 32 s 1 1 0 840 ms 48 s 1 1 1 960 ms 64 s Trigger red Watchdog LED 0 Red LED WD off 1 Red LED WD on Watchdog error Display and reset 0 WD inactive 1 WD triggered Reset LED after w...

Страница 139: ... 1024 byte steps between 4000h and 7C00h through the CAN base address register write only address 066h A limited selection can be preset in the BIOS Setup Note The CAN base address register shares its I O address with other registers The watchdog enable register 066h select register therefore must be selected before access Meaning of the bits CAN base address register write only address 066h Addre...

Страница 140: ...h Bits 15 14 13 8 7 6 5 0 1 1 LED L1 SF dark default 1 0 LED L1 SF lights yellow 0 1 LED L1 SF lights red group fault 1 1 LED L2 R S dark default 1 0 LED L2 R S lights yellow STOP 0 1 LED L2 R S lights green RUN xxxxxx xxxxxx Reserved read write Note The L1 and L2 LEDs indicate by flashing alternatively yellow the progress of the BIOS self test during the device startup When the BIOS self test is ...

Страница 141: ...tatus of the CMOS battery is monitored the status two tier can be read from the battery status register Meaning of the bits Battery status register read only address 50Fh Bit Description 7 6 5 4 3 2 1 0 0 0 CMOS battery capacity is still sufficient 1 0 CMOS battery capacity is exhausted remaining capacity is sufficient for approx one month 1 1 CMOS battery is empty ...

Страница 142: ...he battery buffered SRAM uses a 2 MB memory address area which can be read via the PCI register Meaning of the bits SRAM address register PCI register address SRAM base address register PCI register content SRAM memory address default Length of the memory area 8010 2010h 9040 0000h Address is assigned dynamically depending on device 20 0000h ...

Страница 143: ...as and small businesses EN 61000 6 3 2007 EN 61000 6 1 2007 Industry EN 61000 6 4 2007 EN 61000 6 2 2005 Declaration of conformity The EC declaration of conformity and the corresponding documentation are made available to authorities in accordance with the EC directives stated above Your sales representative can provide these on request Note the installation guidelines The installation guidelines ...

Страница 144: ...equency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed...

Страница 145: ...ns 04 2009 A5E02414743 01 145 CANADA Canadian Notice This Class A digital apparatus complies with Canadian ICES 003 Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada AUSTRALIA This product meets the requirements of the AS NZS CISPR 22 ...

Страница 146: ...Find a contact at Tel 49 911 895 3200 Technical support You can contact technical support for all Industry Automation and Drive Technologies products by Phone 49 180 5050 222 Fax 49 180 5050 223 Internet Online support request form http www siemens com automation support request When you contact the customer support please have the following information for the technician on hand BIOS version Orde...

Страница 147: ... are commonly referred to as ESD devices This is also the international abbreviation for such devices ESD modules are identified by the following symbol CAUTION ESD devices can be destroyed by voltages well below the threshold of human perception These static voltages develop when you touch a component or electrical connection of a device without having drained the static charges present on your b...

Страница 148: ...GLW LQ N9 Figure B 1 Electrostatic voltages on an operator Basic protective measures against electrostatic discharge Ensure good equipotential bonding When handling electrostatic sensitive devices ensure that your body the workplace and packaging are grounded This prevents electrostatic charge Avoid direct contact As a general rule only touch electrostatic sensitive devices when this is unavoidabl...

Страница 149: ...formation System AT Advanced Technology ATA Advanced Technology Attachment ATX AT Bus Extended AWG American Wire Gauge US standard for the cable diameter BIOS Basic Input Output System Basic Input Output System CAN Controller Area Network CD ROM Compact Disc Read Only Memory Removable storage medium for large data volumes CD RW Compact Disc Rewritable Rewritable CD CE Communauté Européenne CE symb...

Страница 150: ...Digital Visual Interface Digital display interface DVI I Digital Visual Interface Digital display interface with digital and VGA signals ECC Error Correction Code Error correction code ECP Extended capability port Extended parallel port EGA Enhanced Graphics Adapter PC to monitor interface ESD Components sensitive to electrostatic charge DM Electronic Manual EIDE Enhanced Integrated Drive Electron...

Страница 151: ...module IRQ Interrupt Request Interrupt request ISA Industry Standard Architecture Bus for expansion modules ITE Information Technology Equipment L2C Level 2 cache LAN Local Area Network Computer network that is limited to a local area LCD Liquid Crystal Display Liquid crystal display LEDs Light Emitting Diode Light emitting diode LPT Line Printer Printer port LVDS Low Voltage Differential Signalin...

Страница 152: ...ve conductor PEG PCI Express Graphics PG Programming device PIC Programmable Interrupt Controller Programmable interrupt controller POST Power On Self Test PXE Preboot Execution Environment Software for running new PCs without hard disk data via the network RAID Redundant Array of Independent Disks Redundant hard disk array RAL Restricted Access Location Installation of device in operating facilit...

Страница 153: ...A Canada standards UMA Unified Memory Architecture Video memory URL Uniform Resource Locator Designation of the full address of an Internet page USB Universal Serial Bus UXGA Ultra Extended Graphics Array Graphic standard maximum resolution 1600x1200 pixels V 24 ITU T standardized recommendation for data transfer via serial ports VDE Verein deutscher Elektrotechniker Union of German Electrical Eng...

Страница 154: ...List of abbreviations C 1 Abbreviations SIMATIC IPC427C 154 Operating Instructions 04 2009 A5E02414743 01 ...

Страница 155: ...ogram data medium or database used either for archiving purposes or for the protection of vital and non replaceable data against loss when the working copy is corrupted Certain applications automatically generate backup copies of data files and manage both the current and the previous versions on the hard disk Baud Physical unit for the step speed in signal transmission Defines the number of trans...

Страница 156: ...edium in card format and without moving parts The CF card contains the non volatile memory and the controller The interface of the CF card corresponds with the IDE interface CF cards can be operated without additional electronics on PCMCIA or IDE hard disk controllers using a plug and socket adapter There are two design forms CF I 42 6 x 36 4 x 3 3 mm and CF II 42 8 x 36 4 x 5 mm Configuration fil...

Страница 157: ...tly increase the speed of computing and program execution compared to the previous generation of single core processors with hyperthreading technology EMC directive Directive concerning Electromagnetic Compatibility Compliance is confirmed by the CE symbol and the EC certificate of conformity Energy management The energy management functions of a modern PC allow individual control over the current...

Страница 158: ...Hibernate file that only needs to be created once HORM ensures restoration of a uniform saved system state when booting This reduces the writing to a CompactFlash medium to a minimum for example when starting up and shutting down Windows Embedded Standard 2009 Hot plug The SATA interface gives the device s hard drive system hot plugging capability Prerequisite for this configuration is a RAID1 sys...

Страница 159: ...ive software applications InterfaceInterface See Interface Physical interconnection cable of hardware elements such as PLCs PCs programming devices printers or monitors Interface for interactive software applications Interface multi point MPI is the programming interface of SIMATIC S7 M7 Allows remote access to programmable modules text based displays and OPs from central locations The MPI nodes c...

Страница 160: ...at can be used to connect a printer Memory card Memory cards in credit card format Memory for user programs and parameters for example for programmable modules and CPs Module Modules are plug in units for PLCs programming devices or PCs They are available as local modules expansion modules interfaces or mass storage Mass storage module Module retainer The module retainer is used to fasten modules ...

Страница 161: ...nalization Not all CD drives can read packet written CDs There are restrictions to using this method in general data transfer PATA Interface for hard disk drives and optical drives with parallel data transmission rate up to 100 Mbps PC card Trademark of the Personal Computer Memory Card International Association PCMCIA Designation for auxiliary cards that conform with PCMCIA specifications A PC ca...

Страница 162: ...dems or printers The user can plug in a peripheral and play it at once without manually configuring the system A Plug Play PC requires both a BIOS that supports Plug Play and a Plug Play expansion card POST Self test performed by the BIOS after the computer is switched on Performs a RAM test and a graphics controller test for example The system outputs audible signals beep codes if the BIOS detect...

Страница 163: ...ows operating system Reset Hardware reset Reset restart of the PC using a button switch Restart Warm restart of a computer without switching the power off Ctrl Alt Del Restore DVD The Restore DVD is used to restore the system partition or the entire hard disk to factory state if the system has crashed The bootable DVD contains all the necessary image files You can also create a boot disk allowing ...

Страница 164: ...ve are added to the hardware configuration SSD Solid State Drive A Solid State Drive is a drive that can be installed like any other drive it does not contain a rotating disk or other moving parts because only semiconductor memory chips of similar capacity will be used This design makes SSDs more rugged provides shorter access times and low energy consumption STEP 7 Programming software for the cr...

Страница 165: ...aborted The operating system is loaded and restarted again The CTRL ALT DEL hotkey can be used to initiate a warm restart WLAN Wireless LAN is a local network that transmits data via radio waves infrared light or another wireless technology Wireless LAN is mainly used for mobile computer applications in office or factory environments ...

Страница 166: ...Glossary SIMATIC IPC427C 166 Operating Instructions 04 2009 A5E02414743 01 ...

Страница 167: ...09 38 Windows XP Professional 40 Compact Flash card Installation removal 65 Compact Flash card interface 111 Connecting 24 V DC power supply 34 Peripherals 33 143 Power supply 33 Connection elements 18 Coupling with SIMATIC S7 43 Creating an image 86 D Data backup 86 Date BIOS Setup 118 DC power supply 96 Declaration of conformity 143 Degree of protection 91 Delivery version 37 Design external 17 ...

Страница 168: ...ws XP Professional 40 Installing a memory module 58 Interfaces 18 Ethernet 18 43 ETHERNET 18 PROFIBUS 18 43 Internal components Overview 105 Internal interfaces 111 IT communication 43 K Keyboard Ports 18 Keyboard Features 120 L Language selection 78 Windows XP 80 License key 74 77 Limitation of Liability 67 Lithium battery 71 M Main memory 93 Messages On the screen 87 Microsoft Windows Product Ke...

Страница 169: ...7 43 Software 74 SRAM 52 SSD drive Partitioning 81 82 Startup 54 87 Status displays 94 Supply voltage 91 System Date 118 System partition 74 77 System resources 135 System Time 118 T Temperature monitoring 46 Third party modules 90 Time BIOS Setup 118 Tools 68 Transport 21 Trigger register Watchdog 138 Troubleshooting FAQs 89 U Unpacking Device 22 Updates Operating system 84 User programs and driv...

Страница 170: ...Index SIMATIC IPC427C 170 Operating Instructions 04 2009 A5E02414743 01 ...

Отзывы: