Technical specifications
7.6 BIOS description
SIMATIC IPC327E
Operating Instructions, 06/2019, A5E40965257-AD
67
Port type
Change Settings
Device Mode
Serial port 5
Auto
IO=2D0h; IRQ=10;
IO=2C0h; IRQ=10;
-
Serial port 6
Auto
IO=2C0h; IRQ=11;
IO=2D0h; IRQ=11;
-
See the options for device mode below:
Configuration options
Description
RS-232
To enable RS-232 mode for serial port 1/2.
RS-422
To enable RS-422 mode for serial port 1/2.
RS-485
To enable RS-485 mode for serial port 1/2.
See the baud rate for RS-422 and RS-485 below: 50, 75, 110,134.5, 150, 300, 600, 1200,
1800, 2000, 2400, 3600, 4800, 7200, 9600, 19200, 38400, 57600, 115200.
Power Management
You can view and configure power management in this page.
Restore AC Power Loss
You can restore the AC power loss with the following steps:
1.
Select Last State, Always On and Always Off with the arrow keys and press Enter key.
2.
Press F4 key and save the change.
See the configuration options for Restore AC Power Loss below:
Configuration
options
Description
Always On
The system goes into on state after the AC power restores.
Always Off
The system goes into off state after the AC power restores.
Last State
The system goes into on state if system state was on before AC power loss; the
system goes into off state if system state was sleep, hibernate or off before AC
power loss.
Resume from Network
You can enable or disable the function of resuming from network with the following steps:
1.
Select Resume from Network with the arrow keys and press Enter key.
2.
Select Disabled or Enabled as you need and press Enter key in the pop-up window.
3.
Press F4 key and save the change.