Operating the display unit
IRD400
28
Operating Instructions, 05/2018, A5E36790512-AC
Communication with a display unit of the same model
In "IR P2P" operating mode, the display unit communicates with another display unit of the
same type. Communication is performed by sending and receiving data packets. The
configuration is used to control whether data packets are sent or received. Note:
●
Throughout the entire duration of the data transmission, the transmission and reception
range of the two display units must overlap.
●
During data transmission, the two display units must face each other and be still.
●
During the period of data transmission, the remote control may not be used.
●
The maximum data rate for the data transmission is 1333 bps
●
A data packet contains 16 bytes of user data.
Additional information is available in the section "Configuring the display unit (Page 29)".
Switching on the display unit
The display unit is switched on via the 24 V DC power supply.