![Siemens SIMATIC CM35 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/siemens/simatic-cm35/simatic-cm35_manual_375032050.webp)
4-3
CM35 Counter Module
(4) J31069-D0416-U001-A5-7618
4.2
Parameterization
The parameter data for the individual operating modes are combined into
parameter blocks. The required number of parameter blocks depends on the
operating mode which you selected.
The parameters must be transferred at least once to the CM35 after CPU
STOP
®
RUN. After the data have been transferred correctly, the red SF
LED goes off and the module is ready for operation.
The parameters can be specified again during operation so that the individual
channels can be adjusted to the particular state of the process.
The parameter blocks can be transferred in any sequence. The order has no
effect on their use.
Note
Before a channel can be reparameterized, it must be stopped. The parameters
for a channel may not be changed or written while the channel is running.
A parameter block consists of the following.
-- A control word
-- Up to 6 words of data area (parameter data)
Table 4-1
Layout of a parameter block
Word
Description
Word 1
Control word
Words 2 to 7
Parameter data
For the allocation and description of the parameter data for the individual
parameter blocks, see the description of the operating mode.
Parameter data
Parameter block
Data Communication with the CM35
Содержание SIMATIC CM35
Страница 1: ...SIMATIC Counter Module CM35 Manual Release 06 2000 ...
Страница 9: ...vi CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Table of Contents ...
Страница 10: ...1 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Product Overview 1 ...
Страница 20: ...2 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description 2 ...
Страница 23: ...2 4 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description ...
Страница 47: ...3 24 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Commissioning ...
Страница 48: ...4 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Data Communication with the CM35 4 ...
Страница 70: ...5 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Pulse Counter Operating Mode 5 ...
Страница 88: ...6 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Period Duration Measurement Operating Mode 6 ...
Страница 98: ...7 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Timer Operating Mode 7 ...
Страница 112: ...8 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode 8 ...
Страница 131: ...8 20 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode ...
Страница 133: ...A 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Literature ...
Страница 134: ...B 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity B ...
Страница 135: ...B 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity ...
Страница 141: ...Glossary 6 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Glossary ...