Configuration
4.9 Cloud configuration
SIMATIC CC712
Operating Instructions, 05/2019, C79000-G8976-C503-01
59
The data management of the subscriptions is stored in the RAM of the gateway.
If there is power down, all data and connection information of subscriptions is lost. After
restarting the server, the client needs to re-establish the connection and set up the
subscriptions again.
Deadband
When monitoring items in the "DataChangeFilter", the OPC UA server of the gateway uses
the filter "AbsoluteDeadband".
4.9
Cloud configuration
4.9.1
Notes on structuring data
Data structures
Depending on the cloud provider, the data is structured differently for transfer to the broker:
●
AWS / Azure / IBM Cloud
–
Topics
A topic is the channel for the transfer of values of one or more data points.
You can create several topics.
No groups can be configured.
●
MindConnect IoT Extension / Other Cloud
–
Groups
A group can contain one or multiple data points.
You can create one or more groups.
–
Topic
You can assign different topics to the groups.
MindConnect IoT Extension: In the default setting, the groups are assigned to the
standard topic "s/us" of the MindConnect IoT Extension.
Structure of the topic names
Because the requirements on the format of the topics can be different depending on the
receiver (broker, cloud), a topic name is made up of different parts.
Prefix and suffix generally apply to all topics.
Prefix and suffix are not relevant for groups.