7-18
SICLOCK
®
PCON
Operating Instructions, 04/2012, A2B00056366E-01
Outputs
Alarm output
Dimensions, weight, and environment
Electrical outputs:
RS422, RS232, TTY/20mA isolated
Voltage output 24 VDC/0.8A
(Supply voltage 12 to 30 VDC, maximum current 800mA),
Voltage output 120 VDC/0.1A isolated
(Supply voltage 24 to 120 VDC, maximum current 100mA)
Short-circuit strength:
Permanently short-circuit-proof and monitored for temperature
Connection:
Terminal strip X2
Optical output:
Version 2XV9450-1AR63-1SA2 multimode FOC 820nm
Connector:
BOFC (ST-compatible with IEC 874/10)
Display:
Yellow LED
Relay contact: 1 changeover contact
DC: 120V 1A/30W
AC: 120V 1A/30W
Alarm monitoring time
3 secs or 3 min
Display:
Red LED
Dimensions (WxDxH):
100x70x135mm
Weight:
460g
Ambient temperature:
Operating mode: 0°C to +50°C
Storage: -25°C to +85°C
Relative humidity:
Operating mode: 10% to 95% (no condensation)
Storage: 10% to 95%