5-14
SICLOCK
®
PCON
Operating Instructions, 04/2012, A2B00056366E-01
Outputs
5
5.1
Voltage output
The power supplies for the 24V/0.8A output and the 24 to 120 VDC/0.1A output
must also be connected externally. The amplitude of the output voltage for the
24V/0.8A output corresponds to the connected supply voltage (12 to 30 VDC).
For the 24 to 120 VDC/0.1 A output, the amplitude of the output voltage corre-
sponds to the connected supply voltage (24 to 120 VDC) minus at least 4V.
The following figure shows the interconnection of the 24V/0.8A output with the
associated power supply.
Fig. 5-1 24V/0.8A voltage output