background image

Answers for infrastructure.

www.usa.siemens.com/reclosers

Installation and 
commissioning report

Type SDR distribution recloser

User

Location

Contract number

Rated maximum voltage (kV)

Auxiliary voltage

Siemens Type SDR

Recloser type

Serial number

Rated continuous current (A)

Rated short-circuit current (kA)

Содержание SDR 15.5 kV

Страница 1: ...Instruction manual Type SDR 15 5 kV to 38 kV three phase distribution recloser Installation operation maintenance E50001 F710 A249 V3 4A00 Answers for infrastructure www usa siemens com reclosers ...

Страница 2: ...nstallation construction or operation of the equipment and the hazards involved In addition this person has the following qualifications Is trained and authorized to de energize clear ground and tag circuits and equipment in accordance with established safety procedures Is trained in the proper care and use of protective equipment such as rubber gloves hard hat safety glasses or face shields flash...

Страница 3: ...on manual shall not become part of or modify any prior or existing agreement commitment or relationship The sales contract contains the entire obligation of Siemens Industry Inc The warranty contained in the contract between the parties is the sole warranty of Siemens Industry Inc Any statements contained herein do not create new warranties or modify the existing warranty Table of contents Introdu...

Страница 4: ...of supply and technical data and also the equipment and special tools supplied are used exclusively for their intended purpose in accordance with the provisions of these operating instructions and applicable laws codes regulations and standards Any other use is forbidden unless the consent of Siemens has been obtained If the above mentioned conditions are not observed or the safety instructions ar...

Страница 5: ...rol power removed before performing any tests maintenance or repair 2 Always perform maintenance on the control cabinet only after the capacitors are discharged see page 13 3 Check to be certain the indicator flag is green indicating that the switch unit is in the open position see Figure 7 4 Always let an interlock device or safety mechanism perform its function without forcing or defeating the d...

Страница 6: ...ion manual does not cover the switch unit mounting frame control and protection relay or related accessories for example surge arresters external voltage sensors modems or radios For information pertinent to the mounting frame for the switch unit refer to the frame installation drawing provided with the order specific drawings For information pertinent to the control and protection relay refer to ...

Страница 7: ...tional 1 2 3 4 5 6 7 8 1 Pole with integrated vacuum interrupter 2 Nameplate 3 Connector for control cable 4 Connector for voltage sensor cable optional 5 Lower terminal usually load side 6 Upper terminal usually line side 7 Ground terminal connection 1 2 3 4 5 6 7 Three phase recloser switch unit with encapsulated vacuum interrupter The three phase recloser switch unit is comprised of the poles t...

Страница 8: ...ts This sequence identifies the currents IA IB and IC of the controller The phase sequence may be changed to match the system phase sequence using the control and protection relay software Figure 3 Pole with integrated vacuum interrupter Figure 4 Pole sequence C B A or 3 2 1 when viewed from this side Figure 5 Detail of pole identification indent phase C or 3 A B C Phase identification indent 1 Up...

Страница 9: ...e switch unit This prevents the occurrence of high voltage on the sensor cable if the sensor cable is removed while the switch unit is in operation Do not disable the varistor circuit Operating mechanism The operating mechanism for the vacuum interrupters is located in a metal housing To meet the required fast reclosing cycles a magnetic actuator with capacitors as energy storage drives the switch...

Страница 10: ...ubicle as described by the type SDR distribution recloser The option for control and protection relays are brand specific This instruction manual includes information on the type SDR controller to supplement information in the control and protection relay instruction manuals The user should consult information on the control and protection vendor s web site for information on the specific relay in...

Страница 11: ... for broken cable and with discharge switch for the capacitors PCB2 not included with the Schweitzer Engineering Laboratories Inc type SEL 651R recloser control relay option PCB3 Capacitors for magnetic actuator PCB3 not included with the Schweitzer Engineering Laboratories Inc type SEL 651R recloser control relay option Note The three phase type SDR controller requires two PCB3 capacitor circuit ...

Страница 12: ...f 1 Connector mounting plate 2 Control cable connector 3 Optional voltage sensor connector 4 Optional auxiliary power connection 5 Optional antenna connector provision Figure 13 Connector mounting plate control cable connector voltage sensor connector and optional antenna or auxiliary power connection Figure 16 Optional door alarm 1 Optional door alarm 1 2 3 4 5 1 2 3 1 1 ...

Страница 13: ...it board PCB2 serves to discharge the capacitors In the discharge capacitors position I the capacitor charging operation is turned off and the capacitors are discharged via a resistor discharge of the capacitors takes roughly one minute When capacitors are charged and the switch is changed from the operating position O to the discharge capacitors I position the red LED next to switch illuminates W...

Страница 14: ...e not in use they should be recharged at intervals of six months Deep discharge protection provided with the Siemens type 7SR224 control and protection relay The controller is equipped with deep discharge protection to avoid damage to the batteries if the auxiliary power supply is absent for an extended time In case of loss of auxiliary supply the recloser will work as long as the internal bus vol...

Страница 15: ...ion must be on delivery receipt 3 Notify the Siemens field service at 1 800 347 6659 or 1 919 365 2200 outside the U S 4 Arrange for carrier s inspection Do not move the unit from its unloading point Handling procedure 1 Carefully remove the packing material from the recloser Keep the shipping pallet for later use if the recloser is to be stored prior to its installation 2 Inspect for concealed da...

Страница 16: ...indoor and outdoor storage to prevent condensation and corrosion The controller space heater should be connected to a 120 Vac auxiliary supply at terminal block X1 as discussed in Connecting the auxiliary voltage supply on page 21 of this instruction manual Refer to the wiring diagrams provided with the order specific drawings for terminal numbers and terminal block location After these connection...

Страница 17: ...ill cause death serious injury or property damage To avoid electrical shock or burns this equipment must be installed operated and maintained only by qualified persons thoroughly familiar with the equipment instruction manuals and drawings Heavy weight Can result in death serious injury or property damage Obtain the services of a qualified rigger prior to hoisting the recloser switch unit to assur...

Страница 18: ...ch 250 lbf ft 40 lbf ft Preparatory work Both the installation and commissioning report see page 32 and these installation instructions are based on the sequence of the work to be performed The on site conditions may result in deviations from the sequence shown The following preparatory work must be performed Instruct installation and maintenance personnel with regard to 1 Safety 2 Cleanliness at ...

Страница 19: ... covers at the recloser switch unit and controller When connecting the cables the covers should be stored in a clean and dry environment such as the controller enclosure in case of later use during disconnection of the cables Electrical installation The following must be carried out in order to establish the electrical connections Establish the ground earth connection Connect the recloser switch u...

Страница 20: ...oes not hang from the connection housing or terminal plug 6 Loop and fasten excess lengths of cable in the area below the pole mounting frame at the highest position possible 7 Cable ties or clamps should be no more than six feet apart on the pole Figure 22 Three phase type SDR controller connections 1 Connector for auxiliary power supply optional 2 Connector for voltage sensor cable optional 3 Co...

Страница 21: ... spade connectors depending on the configuration specified by the purchaser Commissioning The equipment must be commissioned as follows The installation and commis sioning report see page 32 serves as documentation and a checklist Function and operational instructions For functional test and operational instructions for use with the type SDR three phase controller refer to the vendor website infor...

Страница 22: ...itching comprises electrical switching remote and or local operation and mechanical switching by means of the lockout handle Switching is carried out automatically by the controller to protect the network by remote control or manually on site Local operation Local operation describes the manual electrical switching of the recloser on site Manual switching using the lockout handle is discussed in t...

Страница 23: ...action is completed As long as the lockout handle is pulled out it is not possible to close the recloser electrically whether locally or from a remote location Closing the recloser electrically from the controller 1 Using a hot stick or suitable rod from the ground push the lockout handle back in completely 2 Follow the control and protection relay instructions to electrically close the recloser T...

Страница 24: ...and switch on if necessary Failure of batteries The batteries are protected by a miniature circuit breaker in the front of the swing panel 1 Check miniature circuit breaker CB3 and switch on if necessary 2 Check the battery status via the protection and control relay menu or monitoring device and replace batteries if necessary Closing of the recloser is blocked Manual lockout handle is not fully r...

Страница 25: ... work should be carried out as part of regular inspections reflected in Table 3 Spare parts Spare parts must be replaced only by instructed and certified personnel Refer to list in Table 4 Hazardous voltages Will cause death serious injury or property damage Always de energize and ground the equipment and all terminals before performing any work near high voltage conductors Work on the recloser sw...

Страница 26: ...and commissioning section of the control and protection relay instruction manual 2 Function test of lockout handle Four years adjust interval according to experience Reset counter Switching operations since last visit refer to control and protection relay instructions Following every maintenance session Table 3 Maintenance plan Accessory spare part Order number Surge arresters 3EK7 On request Auxi...

Страница 27: ... 8 376 14 8 376 Flashover distance Unit Phase phase in mm 12 3 312 12 3 312 12 3 312 12 3 312 Phase ground earth in mm 10 4 265 10 4 265 13 4 340 13 4 340 Creepage distance Unit Phase ground earth in mm 31 9 810 31 9 810 50 8 1 290 50 8 1 290 Between line side and load side terminal in mm 46 1 1 170 46 1 1 170 54 8 1 390 54 8 1 390 Table 5 Main characteristic data Protective function Unit Minimum ...

Страница 28: ...d in line with Figure 29 Example At 2 500 m altitude a unit rated 110 kV BIL under usual service conditions will have a lightning impulse withstand capability of 110 K 110 em h 1000 8150 110 1 2 91 5 kV Table 9 Power consumption Auxiliary system Unit Power consumption Auxiliary power requirement controller W 15 typically 10 Auxiliary power requirements heating controller and switch unit W Control ...

Страница 29: ...0 Recloser switch unit dimensions in mm 1 All voltages 18 1 460 2 All voltages 20 5 521 3 15 5 kV and 27 0 kV 24 2 615 38 0 kV 27 4 695 4 15 5 kV and 27 0 kV 37 9 962 38 0 kV 43 2 1 097 5 15 5 kV and 27 0 kV 23 5 597 38 0 kV 28 8 732 6 15 5 kV and 27 0 kV 9 8 250 38 0 kV 13 0 330 7 All voltages 14 4 365 8 All voltages 14 8 376 9 All voltages 46 2 1 173 10 All voltages 0 4 10 11 All voltages 0 88 2...

Страница 30: ... length x width x height without pole mount brackets in mm 18 0 457 x 14 0 356 x 36 0 914 Weight without batteries lbs kg 150 67 Figure 31 Controller dimensions in mm 1 18 0 457 2 14 0 356 3 36 0 914 4 40 5 1 029 center line pole mounting bracket bolt holes 1 2 3 4 ...

Страница 31: ...ign code 9 Date of manufacture production date 10 Rated continuous current Ir 11 Rated symmetrical interrupting current Isc 12 Weight 13 Standard 14 Product type style 15 Sales order number 16 Sales item number 17 Switch type 18 Instruction manual code Product Type Style Switch Manufacturer e p y T h c t i w S o N r e d r O s e l a S o N l a i r e S o N m e t I s e l a S Serial No Production Date ...

Страница 32: ...32 Installation and commissioning report Installation and commissioning report The installation and commissioning report on the following pages is intended for using and copying as a checklist ...

Страница 33: ...losers Installation and commissioning report Type SDR distribution recloser User Location Contract number Rated maximum voltage kV Auxiliary voltage Siemens Type SDR Recloser type Serial number Rated continuous current A Rated short circuit current kA ...

Страница 34: ...er installation Item Checklist Notes B 01 All bolted connections and other assembly elements are tight B 02 Batteries are installed correctly All four are connected in series Contacts point to the center of the battery tray Polarity labeling on the supply wires on the left and right correspond to actual connection of the batteries Hook and loop straps are over the batteries and fastened tightly B ...

Страница 35: ... next to the Close function button is no longer lit LED next to the Open function button lights up green Position indicator on the bottom of the recloser switch unit is green open C 04 Press the Close function button on the control and protection relay and then press Enter Recloser closes LED next to the Open function button is no longer lit LED next to the Close function button lights up red Duri...

Страница 36: ...t LED next to the Close function button lights up red Position indicator on the bottom of the recloser switch unit is red C 11 Switch on miniature circuit breaker CB2 At external temperatures of 95 ºF 35 ºC the heaters heat up after approximately one minute Item Checklist Notes D 01 Adjust the control and protection relay to the desired setting file The control and protection relay shows default s...

Страница 37: ... On site instruction on recloser controller E 04 Order specific drawings are available E 05 Type 7SR224 quick reference guide available Table 16 Other services Job Name Department Date Signature Technician Commissioning engineer Owner Supervisor Instructed person Table 17 Remarks Table 18 Signatures ...

Страница 38: ...agnetic actuator type SDR switch unit driver electronics PCB2 and capacitors PCB3 are not utilized http www selinc com SEL 651R National Instruments Corporation CompactRIO or cRIO controller for use as intelligent grid switching device only http www ni com compactrio Annex A Control and protection relay options for Siemens Distribution Feeder Automation SDFA include Siemens type 7SC80 feeder autom...

Страница 39: ...39 ...

Страница 40: ... only exist if expressly agreed in the terms of contract All product designations may be trade marks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could vio late the rights of the owners Subject to change without prior notice Order No E50001 F710 A249 V3 4A00 All rights reserved Printed in USA 2012 Siemens Industry Inc Siemens Industry Inc 7...

Отзывы: