![Siemens SCD 1515-E Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/siemens/scd-1515-e/scd-1515-e_operating-instruction_381850050.webp)
Operating Instruction
Main menu
Function
Adjust function / value / range
Description
Options 2
DPMS
ON – OFF
Display Power Management System (DPMS) on or off
If DMPS activated, the monitor is turn off (backlight) when a
synch signal is left. The screen is dark.
Source scan
OFF – ON – Standard
Standard: ON
Note: To scan new video source is not relevant because the
monitor has one RGB input source only.
Blank color
red – green – blue – black
Choose the background color of the screen when no input signal
is present.
Frame color
red – green – blue – black
Choose the frame color of the screen when input signal does not
fill screen (see scaling).
Info signal source
ON – OFF
Input source icon on or off
The icon is shown when input signal are changed. The icon
shows the following information’s:
-
signal source (e.g. RGB analog)
-
Mode number (internal mode number of the timing list)
-
Image resolution of the input signal
-
H-
and
V-frequency
Utilities
Language
English – German
OSD language
Calibration
<+> press
Adjustment of the internal A/D converter
(following the menu instruction)
freeze frame
ON – OFF
freeze the actual shown picture
Factory reset
<+> press
Reset of values like brightness, contrast,.. to default values
Installation RGB-Mode
<+> press
Enter a new timing which is not in the internal timing table. This
function should used, when the shown image resolution is not
the resolution are expect.
When press <+> the sub menu expect 9 timing parameter.
When
<+>,
H- and V-Frequency
–
Show the H- and V-Frequency of the present input signal.
H/V-total, H/V-start
–
Show the used timing parameter of the present input signal
Option
Var. RGB-Mode inactive, Mode1, Mode2,
Mode3
Inactive: used the internal timing table only
Mode1: use the timing parameter and perform a complete auto
adjustment. (usually used)
Mode2: use the timing parameter and perform an auto
adjustment without an automatic image position adjustment.
Mode3: use the timing parameter and perform an auto
adjustment without an automatic frequency adjustment.
H-resolution
100 to 2000 through key (+/-)
Horizontal image resolution (important parameter)
V-resolution
100 to 2000 through key (+/-)
Vertical image resolution (important parameter)
H-total
100 to 2500 through key (+/-)
Whole pixel per line (important parameter)
H-Start
0 to 750 through key (+/-)
Number of Pixels from H-sync start to image start
V-Start
0 to 500 through key (+/-)
Number of lines from V-sync start to image start
Install
<+> press
Activate the feed timing parameter
test pattern
<+> press
Show a test image
Info Firmware,
Resolution,
Timing
–
Show the firmware version and timing data of the present input
signal
LCD-Monitor SCD 1515-E
page 50 / 56
DOC-No.: B30058DE8.doc
Содержание SCD 1515-E
Страница 27: ...Bedienungshandbuch 5 2 Timingliste 15KHz LCD Monitor SCD 1515 E Seite 27 52 DOC Nr B30058DE8 doc ...
Страница 28: ...Bedienungshandbuch LCD Monitor SCD 1515 E Seite 28 52 DOC Nr B30058DE8 doc ...
Страница 55: ...Operating Instruction 5 2 Timinglist 15 KHz LCD Monitor SCD 1515 E page 55 56 DOC No B30058DE8 doc ...
Страница 56: ...Operating Instruction LCD Monitor SCD 1515 E page 56 56 DOC No B30058DE8 doc ...