![Siemens SCALANCE XC-200 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/siemens/scalance-xc-200/scalance-xc-200_operating-instructions-manual_383834064.webp)
Technical specifications
7.3 Technical specifications SCALANCE XC206-2SFP
SCALANCE XC-200
64
Operating Instructions, 07/2016, C79000-G8976-C442-01
Technical specifications
Dimensions (W x H x D)
60 x 147 x 125 mm
Weight
520 g
Installation options
•
Wall mounting
•
Installation on a DIN rail
•
Mounting on an S7-300 standard rail
•
Mounting on an S7-1500 standard rail
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
> 47 years
Switching properties
Aging time
45 seconds
Max. number of learnable MAC
addresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
4
1)
Note the wiring rules (Page 49).
2)
Detected with the SFP992-1ELH. You will find the precise values in the operating
instructions of the pluggable transceivers, see the section "Introduction" Additional
documentation (Page 5).
3)
Depending on which pluggable transceiver you use, the maximum ambient temperature
can change, see section "Accessories", Pluggable transceivers SFP (Page 18)".