Technical specifications
8.1 SCALANCE X414-3E and X408-2 - technical specifications
SCALANCE X-400
140
Operating Instructions, 06/2015, C79000-G8976-C186-12
SCALANCE X414-3E
SCALANCE X408-2
Current consumption at 24 V DC < 2000 mA
< 700 mA
Load on the signaling contact
24 V DC / max. 100 mA safety
extra-low voltage (SELV)
24 V DC / max. 100 mA safety
extra-low voltage (SELV)
Overvoltage protection at input
Non-replaceable fuse (F 3.15 A /
250 V)
Non-replaceable fuse (F 3 A /
32 V)
Digital Inputs
Input voltage:
•
Rated value 24 V DC safety
extra-low voltage (SELV)
•
For state "1": + 13 V ...+ 30 V
•
For state "0": – 30 V to + 3 V
Max. input current: 8 mA
Max. cable length: 30 m
Inputs isolated from electronics.
Inputs not present.
C-PLUG
SCALANCE X414-3E
SCALANCE X408-2
Dimensions (width x height x
depth)
24.3 x 17.0 x 8.1 mm
24.3 x 17.0 x 8.1 mm
Weight
approx. 5 g
approx. 5 g
Power consumption
0.015 W
0.015 W
Memory capacity
32 Mbytes
32 Mbytes
Permitted cable lengths
SCALANCE X414-3E
SCALANCE X408-2
TP cable length
With TP cord up to 10 m,
with
FastConnect cabling system up
to 100 m.
With TP cord up to 10 m,
with
FastConnect cabling system up
to 100 m.
Redundancy reconfiguration times
Redundancy
Reconfiguration times
HRP
300 ms
Standby link
300 ms
MRP
200 ms