background image

Dimension drawings 

 

 

 

SCALANCE X-300M PoE 

48

 

Compact Operating Instructions, 05/2016, A5E02630810-09 

Содержание SCALANCE X-300M PoE

Страница 1: ..._________________ ___________________ ___________________ ___________________ SIMATIC NET Industrial Ethernet switches SCALANCE X 300M PoE Compact Operating Instructions 05 2016 A5E02630810 09 Introduction 1 Safety notes 2 Description 3 Assembling 4 Connecting 5 Technical data 6 Dimension drawings 7 Approvals 8 Appendix A ...

Страница 2: ...perated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Si...

Страница 3: ...LUG 20 3 5 2 Removing and inserting the C PLUG compact housing 21 4 Assembling 23 4 1 Safety notices for installation 23 4 2 Suitable cables for temperatures above 70 C cable 50 C 70 C ATEX 24 4 3 Notes on installation 24 4 4 Installing on an S7 300 standard rail 25 4 5 Installation on a DIN rail 25 4 6 Wall mounting 26 4 7 Fitting and removing media modules and SFPs 27 5 Connecting 29 5 1 Safety ...

Страница 4: ...6 4 Other properties 41 7 Dimension drawings 45 8 Approvals 49 8 1 X 300M PoE approvals certificates 49 8 2 SCALANCE X 300 declaration of conformity 53 8 3 Overview of the approvals 53 8 4 Mechanical stability in operation 53 A Appendix 55 A 1 The connector system M12 X coded according to IEC 61076 2 109 55 Index 57 ...

Страница 5: ...in these operating instructions compact Classification Description Terms used Product line For all devices and variants of all product groups within the SCALANCE X 300 product line the term IE switches X 300 is used IE switches X 300 Product group For all devices and variants of a product group only the product group is used X 300M PoE Device For a device only the device name is used X308 2M PoE V...

Страница 6: ...Here you can register for a product specific newsletter For the safe operation of a plant machine however it is also necessary to integrate the automation components into an overall IT security concept for the entire plant machine which corresponds to the state of the art IT technology You will find information on this in http www siemens com industrialsecurity Products from other manufacturers th...

Страница 7: ... port 100 Mbps multimode FO cable up to max 5 km LD FE SC port 100 Mbps single mode FO cable up to max 26 km SC port 1000 Mbps multimode FO cable up to max 750 m LD SC port 1000 Mbps single mode FO cable up to max 10 km LH SC port 1000 Mbps single mode FO cable up to max 40 km LH SC port 1000 Mbps single mode FO cable up to max 70 km If information applies to all devices the term IE Switches X 300...

Страница 8: ...Introduction 1 2 Type designation SCALANCE X 300M PoE 8 Compact Operating Instructions 05 2016 A5E02630810 09 ...

Страница 9: ... use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD DO NOT OPEN WHEN ENERGIZED This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only This equipment is suitable for use in Class I Zone 2 Group IIC or non hazardous locations only Safety notices on the use of the device The following saf...

Страница 10: ...ety extra low voltage combined with a following NEC Class 2 power limiter also meets the requirements according to IEC 60950 1 EN 60950 1 VDE 0805 1 or NEC Class 2 A suitable power limiter is for example the redundancy module SITOP PSE202U NEC Class 2 article number 6EP1962 2BA00 WARNING Opening the device DO NOT OPEN WHEN ENERGIZED General notices about use in hazardous areas WARNING Risk of expl...

Страница 11: ...ted in an air ambient in excess of 50 C 70 C only use cables with admitted maximum operating temperature of at least 80 C WARNING Protection against transient voltage surges Provisions shall be made to prevent the rated voltage from being exceeded by transient voltage surges of more than 40 This criterion is fulfilled if supplies are derived from SELV Safety Extra Low Voltage only 2 1 Important no...

Страница 12: ...ns 05 2016 A5E02630810 09 2 2 PELV Note Safety extra low voltage The supply of the devices by PELV Protective Extra Low Voltage according to DIN VDE 0100 410 or IEC 60364 4 41 is permitted when the generated nominal voltage does not exceed the voltage limits 25 VAC or 60 VDC ...

Страница 13: ...lectrical 10 100 1000 Mbps Module slots X308 2M PoE 4 2 Components of the product The following parts ship with a SCALANCE X 300M PoE Device with C PLUG exchangeable medium 4 pin terminal block for the power supply 2 pin terminal block for the signaling contact Product CD with documentation and software Order numbers Type Order number X308 2M PoE 6GK5 308 2QG00 2AA2 ...

Страница 14: ... equipment These inject power onto the Ethernet cable PD powered devices These are supplied with power via Ethernet The PoE ports of the switch As a PSE the X308 2M PoE supplies PoE compliant devices with power over Ethernet The 48 V power required to supply the powered devices is generated internally on the switch no extra power supply unit is necessary The X308 2M PoE uses the alternative A for ...

Страница 15: ...e SET SELECT button is located on the top of the housing of devices of the X 300 EEC series On all other devices this button is on the front panel of the housing beside the LED display The SET SELECT button has several functions that are described below Change the display mode By pressing the button briefly you change to the display mode of the LED display For more detailed information on this top...

Страница 16: ...e is active you will need to press the SET SELECT briefly possibly several times until display mode B is active 2 Hold down the SET SELECT button for five seconds After three seconds the DM LED begins to flash If you release the button before the five seconds have elapsed the action is aborted 3 The result of the action depends on the initial situation If the redundancy manager and media redundanc...

Страница 17: ...curred red flashes Bad firmware image During normal operation the F LED provides the following information LED color LED status Meaning during operation off No operating problems red on The device has detected an error The signaling contact opens The DM LED for the display mode The DM LED Display Mode indicates which of the four display modes A B C or D is currently active The meaning of the L1 L2...

Страница 18: ...higher than 17 V redundant supply The following applies to the X 300EEC For devices with power supply unit 24 to 48 VDC Limit voltage 17 VDC For devices with a multiple range power supply unit 100 to 240 VAC 60 to 250 VDC Limit voltage 46 5 VDC or 80 VAC Meaning in display mode D LED Color Status Meaning L1 L2 _ off Power supply L1 L2 is not monitored If L1 L2 falls below 17 V the signaling contac...

Страница 19: ...sts and port in normal status In this status the port can receive and send data flashes once per second Link exists and port in blocking status In this status the port only sends and receives management data no user data flashes 3 times per sec ond Link exists and port turned off by management In this status no data is sent or received via the port flashes 4 times per sec ond Port exists and is in...

Страница 20: ...as established at the port for example no cable insert ed this triggers the signaling contact and an error state results 3 5 C PLUG 3 5 1 Area of application and function of the C PLUG Area of application The C PLUG configuration plug that ships with the product is an exchangeable memory medium for storing the configuration data of the device The device can also be operated without a C PLUG This a...

Страница 21: ...written This mode is active when a C PLUG is inserted With written C PLUG A device with an accepted C PLUG inserted uses the configuration data of the C PLUG automatically when it starts up Acceptance is possible only when the data was written by a compatible device type Response to errors Inserting a C PLUG that does not contain the configuration of a compatible device type accidentally removing ...

Страница 22: ...f the C PLUG position A and the slot and release the C PLUG 4 Remove the C PLUG and close the housing again with the sealing screw Inserting the C PLUG 1 Turn off the power to the device 2 Remove the sealing screw on the rear of the device with a coin or a wide blade screwdriver 3 The housing of the C PLUG has a protruding ridge on the long side position B The slot has a groove at this position In...

Страница 23: ...ss 1 Division 2 or zone 2 WARNING When used in hazardous environments corresponding to Class I Division 2 or Class I Zone 2 the device must be installed in a cabinet or a suitable enclosure Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protectio...

Страница 24: ...of the device so that only qualified personnel and trained users have access to it Accessories mounting support installation guidelines When installing the SCALANCE X 300 keep the following points in mind Only use approved components mounting brackets SFPs 19 inch inserts etc in conjunction with the SCALANCE X 300 Only then can you be sure that the device will operate reliably and problem free Wit...

Страница 25: ...ired for example for the signaling contact according to the descriptions in the section Connecting up Removing 1 Remove all cables connected to the X 300 2 Release the screws on the bottom of the housing 3 Remove the X 300 from the S7 300 standard rail 4 5 Installation on a DIN rail WARNING No DIN rail mounting in shipbuilding and when subject to severe vibration The 35 mm DIN rail DIN EN 60715 do...

Страница 26: ...er cables required for example for the signaling contact according to the descriptions in the section Connecting up Removing 1 Remove all cables connected to the X 300 2 Use a screwdriver to lever down the spring catch of the device and pull the lower part of the device away from the rail 3 Remove the device from the upper edge of the DIN rail 4 6 Wall mounting Wall mounting 1 For wall mounting us...

Страница 27: ...0 Note For wall mounting of a rack device R use suitable fittings and mount the device as shown in the drawing 4 7 Fitting and removing media modules and SFPs NOTICE Read the Operating Instructions compact of the SCALANCE MM900 and SCALANCE SFP Before inserting or removing media modules or SFPs make sure that you have read the information in the Operating Instructions compact of the SCALANCE MM900...

Страница 28: ...Assembling 4 7 Fitting and removing media modules and SFPs SCALANCE X 300M PoE 28 Compact Operating Instructions 05 2016 A5E02630810 09 ...

Страница 29: ...ctrical Code r ANSI NFPA 70 If the equipment is connected to a redundant power supply two separate power supplies both must meet these requirements NOTICE Failure of the data traffic due to contamination of optical plug in connections Optical sockets and plugs are sensitive to contamination of the end face Contamination can lead to the failure of the optical transmission network Close unused optic...

Страница 30: ...ng safety notices in addition to the general safety notices for protection against explosion WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON HAZARDOUS Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for ...

Страница 31: ... X 300 X 400 section X 300 Ring Configuration If the device is intended to operate as the redundancy manager Redundancy manager enabled must also be set Standby coupling Standby connection must be enabled and the Standby connection name must match the name of the partner device You will also need to configure the port with Enable Standby Port Monitoring see Configuration Manual SCALANCE X 300 X 40...

Страница 32: ...ver the DIN rail Mounting the switch on an S7 standard rail The switch is grounded over the screw on the rear of the device Mounting the switch on a wall IE Switches X 300 must be grounded with minimum resistance The switch is grounded via the unpainted holes in the housing of the switch and the securing screws If the switch is mounted on a non conductive base you will need to use the grounding ca...

Страница 33: ...for XR 300M and XR 300M PoE At the signaling contact there is always a voltage of 24 VDC even if the device can be operated with 100 to 240 VAC The signaling contact is connected to a 2 pin plug in terminal block The signaling contact can be subjected to a maximum load of 100 mA safety extra low voltage SELV 24 V DC Table 5 1 Pin assignment of the 24 VDC signaling contact Pin number Assignment Pin...

Страница 34: ...res are necessary to prevent interference by strong electromagnetic pulses on the supply lines These can result for example due to lightning or switching of large inductive loads One of the tests used to attest the immunity of devices of the IE Switches X 300 to electromagnetic interference is the surge immunity test according to EN61000 4 5 This test requires overvoltage protection for the power ...

Страница 35: ...y SCALANCE X 300M PoE Compact Operating Instructions 05 2016 A5E02630810 09 35 Terminal block assignment 4 pin Table 5 2 Pinout of the 24 V safety extra low voltage SELV Pin number Assignment Labeling example Pin 1 L1 24 VDC Pin 2 M1 Pin 3 M2 Pin 4 L2 24 VDC ...

Страница 36: ...Connecting 5 6 Connecting the external 24 VDC power supply SCALANCE X 300M PoE 36 Compact Operating Instructions 05 2016 A5E02630810 09 ...

Страница 37: ...124 mm Weight 1150 g Degree of protection IP20 Table 6 2 Installation options Installation options DIN rail 1 S7 300 standard rail Wall 1 Note When used in shipbuilding installation on a 35 mm DIN rail is not permitted In ships the 35 mm DIN rail does not provide adequate support Table 6 3 Permitted ambient conditions Storage transport temperature 40 C to 85 Max relative humidity in operation at 2...

Страница 38: ...tal 40 C to 50 Vertical 40 C to 45 Media module MM992 2SFP with pluggable transceiver SFP991 1 SFP991 1LD SFP992 1 SFP992 1LD Horizontal 40 C to 60 Vertical 40 C to 45 Media module MM992 2SFP with pluggable transceiver SFP991 1LH SFP992 1LH SFP992 1LH SFP992 1ELH SFP991 1ELH200 Horizontal 40 C to 50 Vertical 40 C to 45 MM991 2P 25 C to 40 1 Only hardware product version 02 of the media modules is ...

Страница 39: ...ers Table 6 6 Electrical data Power supply Rated voltage Voltage range Permitted voltage range including total ripple 24 VDC 19 2 VDC 28 8 VDC 18 5 VDC 30 2 VDC Table 6 7 Electrical data Power consumption and redundancy Current consumption 2 A Max power consumption incl PoE power supply of the connected PoE devices PDs 48 W Power loss at 24 VDC 17 W Overcurrent protection of the power supply Non r...

Страница 40: ...ower per port 15 4 W at port of which the following can be used by the PD 12 95 W Overall power on all 4 ports Max 30 8 W Table 6 11 Electrical isolation Between the ports No Between ports and ground Yes Between ports and 24 VDC power input Yes Table 6 12 Pin assignment of the Ethernet ports of the SCALANCE PoE switch Pin number wire 1 Assignment for data transmis sion Assignment for power transfe...

Страница 41: ...Outlet RJ 45 10 m TP cord 0 to 90 m 10 m TP cord with IE FC RJ 45 Plug 180 0 to 100 m Table 6 14 Permitted cable lengths copper cable gigabit Ethernet Cable type Accessory plug outlet TP cord Permitted cable length IE FC Standard Cable 4 2 24 AWG IE FC Flexible Cable 4 2 24 AWG with IE FC RJ 45 Plug 180 4 2 0 to 90 m IE FC Standard Cable 4 2 22 AWG with IE FC Outlet RJ 45 10 m TP cord 0 to 60 m 10...

Страница 42: ...at 40 C In the calculation of the MTBF of a modular switch the standard parts count applies in other words the reciprocals of all component failure rates are added The reciprocal of this total id the MTBF of the entire assembly Note The IE Switches X 300 support full wire speed switching complying with IEEE 802 3 on all ports The number of packets therefore depends on the packet length Table 6 17 ...

Страница 43: ...d in a line influences the frame delay time When a frame passes through the switch this is delayed by the Store Forward function of the IE Switch X 300 by the following values at 64 bytes frame length Delay of approx 10 microseconds at 100 Mbps at 1500 bytes frame length Delay of approx 130 microseconds at 100 Mbps This means the more IE Switches X 300 a frame runs through the higher the frame del...

Страница 44: ...Technical data 6 4 Other properties SCALANCE X 300M PoE 44 Compact Operating Instructions 05 2016 A5E02630810 09 ...

Страница 45: ...SCALANCE X 300M PoE Compact Operating Instructions 05 2016 A5E02630810 09 45 Dimension drawings 7 All dimensions in the drawings are in millimeters Image 7 1 X308 2M PoE Front view ...

Страница 46: ...Dimension drawings SCALANCE X 300M PoE 46 Compact Operating Instructions 05 2016 A5E02630810 09 Image 7 2 X308 2M PoE Side view ...

Страница 47: ...Dimension drawings SCALANCE X 300M PoE Compact Operating Instructions 05 2016 A5E02630810 09 47 Image 7 3 X308 2M PoE Drilling template ...

Страница 48: ...Dimension drawings SCALANCE X 300M PoE 48 Compact Operating Instructions 05 2016 A5E02630810 09 ...

Страница 49: ...proval You will find shipbuilding approvals on the Internet on the pages of Siemens Industry Automation Customer Support under the following entry ID 33118441 http support automation siemens com WW view en 33118441 Entry list tab entry type Certificates EC directives SIMATIC NET products meet the requirements and aims of the following EC directives EMC directive electromagnetic compatibility The S...

Страница 50: ...ble products can always be found on the Internet under the specified entry IDs Internet pages Industrial Ethernet PROFINET Industrial Ethernet System Manual Industrial Ethernet PROFINET Passive network components System Manual You will find information on the system manuals in the section ID 27069465 http support automation siemens com WW view en 27069465 in Further documentation EMC Installation ...

Страница 51: ...ection directive WARNING When using SIMATIC NET products in hazardous area zone 2 make absolutely sure that the associated conditions in the following document are adhered to SIMATIC NET Product Information Use of subasseblies modules in a Zone 2 Hazardous Area You will find this document on the data medium that ships with some devices on the Internet pages of Siemens Industry Online Support http ...

Страница 52: ...eral requirements FM The product meets the requirement of the standard Factory Mutual Approval Standard Class Number 3611 C Tick The product meets the requirements of the AS NZS 2064 standard Class A cULus Approval for Information Technology Equipment cULus Listed I T E Underwriters Laboratories Inc complying with UL 60950 1 Information Technology Equipment CSA C22 2 No 60950 1 03 Report no E11535...

Страница 53: ...drop down list Result A list of the available certificates is displayed 8 3 Overview of the approvals Table 8 1 Overview of the approvals Device c UL us Inf Tech Eq c UL us for Hazardous Locations 1 FM1 C TICK CE ATEX95 Zone 2 1 X308 2M PoE 1 For temperature information T or the maximum ambient temperature Ta refer to the type plate Note Shipbuilding approval You will find shipbuilding approvals o...

Страница 54: ...provals 8 4 Mechanical stability in operation SCALANCE X 300M PoE 54 Compact Operating Instructions 05 2016 A5E02630810 09 IEC 60068 2 27 shock Securing on a DIN rail 15 g 11 ms duration 6 shocks per axis ...

Страница 55: ...mental conditions dust dampness Due to the locking technology standardized for the M12 connectors a high resistance to vibration is achieved Numerous SCALANCE devices therefore provide connection options for X coded M12 connectors Pin assignment A Front view of M12 connector X coded according to IEC61076 2 109 B Front view of RJ 45 connector latching nose at the top with pin assignment according t...

Страница 56: ...Appendix A 1 The connector system M12 X coded according to IEC 61076 2 109 SCALANCE X 300M PoE 56 Compact Operating Instructions 05 2016 A5E02630810 09 ...

Страница 57: ...oE Compact Operating Instructions 05 2016 A5E02630810 09 57 Index G Glossary 6 S Safety notices for installation 23 general 9 Use in hazardous areas 9 23 29 when connecting up 29 SIMATIC NET glossary 6 System manual 50 ...

Страница 58: ...Index SCALANCE X 300M PoE 58 Compact Operating Instructions 05 2016 A5E02630810 09 ...