Configuration / project engineering
5.8 Configuring with the PRESET PLUG
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
223
2.
Start Web Based Management; there you will see the current settings of the PRESET
PLUG.
3.
Make the required changes to the configuration.
4.
In the "Modify C-PLUG" drop-down list box, select the "Create PRESET-PLUG" entry.
5.
In the "PRESET PLUG for" box, specify the device for which you want to create the
PRESET PLUG.
6.
Click the "Modify" button to transfer the configuration of the device to the PRESET PLUG.
7.
Turn the device off and remove the PRESET PLUG.
5.8.4
Putting a device into operation with a PRESET PLUG
Procedure
Note
To work correctly, the PRESET PLUG must have a content that matches the target device.
Follow the steps below to put a device into operation with the configuration data on a
PRESET PLUG.
1.
Insert the PRESET PLUG in the C-PLUG slot of the device to which you want to assign a
configuration.
2.
Turn on the power to the device. The LEDs "P1" and "R1" (and "Rx" on a SCALANCE W-
700 with more than one wireless interface) flash yellow to signal that the PRESET PLUG
was detected.
3.
Press the reset button beside the C-PLUG briefly to save the settings of the PRESET
PLUG on the device.
4.
When all the data has been transferred from the PRESET PLUG to the device, the LEDs
stop flashing and are permanently lit.
5.
Turn the device off and remove the PRESET PLUG.
Note
The next time the device starts up, it uses the settings from the PRESET PLUG and the
previous IP configuration.