Disposal 

All electrical and electronic devices are not to be 
disposed of as ordinary municipal waste, but rather at 
approved disposal facilities for such materials. 
A crossed-out trash bin symbol on a product indicates 
that the product is subject to EU Directive 2002/96/EC. 
Proper disposal and separate collection of such 
equipment is intended to prevent potential harm to health 
and the environment. 
They are prerequisites for re-use and recycling of used 
electrical and electronic devices. 
Detailed information on the disposal of used equipment 
can be obtained from your local authorities, your waste 
disposal service or the authorized dealer from whom you 
purchased the product. 

Содержание SAP14

Страница 1: ...pecific safety standards or regulations for project planning operating and dispo sing of the product z The device is always to be disconnected from the mains or battery prior to performing maintenance work or installing additional devices Liability claim z Do not connect the device if components are missing or damaged z Only make changes to the unit that are explicitly mentioned in this document o...

Страница 2: ...lities Danger of explosion z Make sure that the battery poles do not short circuit z Please pay attention to battery polarity z Always fasten the battery in place with the holder intended for this purpose Technical data Mains voltage 230 V AC 10 15 50 Hz Power intake max 34 VA at 230 V AC Mains supply fuse 160 mA T Mains power Output voltage current 13 7 V DC 1 3 A Max ripple at 1 3 A 60 mV Relay ...

Страница 3: ... 3 Fig 1 2 Remove cover 1 2 4 5 6 7 10 3 8 9 R45 F1 B4 F2 1 F3 3 F4 4 F5 6 Fig 2 Power supply assembly circuit board SMP14 1 LED flashes when E bus communication is intact 2 Address button 3 Not used 4 E Bus connection to burglary detection control unit B1 B2 B3 B4 B4 is secured by F1 5 4 outputs 12 V 1 3 4 6 which are each secured with a fuse F2 to F5 6 Output for mains supply indication not fuse...

Страница 4: ...y 1 5 cm proud B Fig 3 4 Snap the spacers in at the four mounting holes from the back in the intended slots Fig 3 5 Route the connection cable through the cut outs D in the back wall and hang the back on the screws 6 Tighten the screws Fig 4 Mount boards option 1 Snap the fastening supports included with the board into the intended holes A Fig 4 2 Fit circuit boards B Fig 4 Wiring The terminals ca...

Страница 5: ...he base of the housing 4 Connect the mains to the mains supply terminals ground wire E null N and phase U 5 Secure the cable to the clips in the rear wall using cable ties Fig 6 A E bus from control unit B E Bus to other accessories E Bus Cable type IYSTY 2 x 2 x Ø 0 6 mm is recommended The total length of the E Bus cable must not exceed 500 m The power supply unit circuit board SMP14 and the opti...

Страница 6: ...battery in the space provided in the base of the housing 2 Mount the battery holder angle 3 Connect the pre installed battery cables blue red Fig 9 Close and seal the housing 1 Glue the circuit diagram to the inside of the cover 2 Engage the cover in the retainer 3 Connect the earthing lead 1 Fig 9 to the cover 4 Lightly lift and close the cover 5 Screw the cover closed 6 Use eye 2 Fig 9 to seal W...

Страница 7: ...duct indicates that the product is subject to EU Directive 2002 96 EC Proper disposal and separate collection of such equipment is intended to prevent potential harm to health and the environment They are prerequisites for re use and recycling of used electrical and electronic devices Detailed information on the disposal of used equipment can be obtained from your local authorities your waste disp...

Страница 8: ...mbH Co oHG 76181 Karlsruhe Germany www buildingtechnologies siemens com 2009 Copyright by Siemens Building Technologies Liefermöglichkeiten und technische Änderungen vorbehalten Data and design subject to change without notice Document no A6V10236281 Edition 19 01 2009 ...

Отзывы: