31
Permanent installation
The appliance can be installed on a permanent
basis using window/wall Optional Accessory,
reference S1 RKZ 06009, available from your
supplier.
❏
A hole must be made in the wall and the wall
accessory fitted in order to expel hot air.
❏
Store the diffusion duct away and connect the air
expulsion duct to the accessory.
❏
Only the transparent end section of the
accessory is used when air is to be expelled
through a window on a permanent basis. A
10.5-cm. diameter hole must be made in the
glass in order to fit the accessory.
N.B.
• Do not extend the hot-air expulsion duct more
than necessary (maximum length: 140 cm.).
• There must be a distance of at least 70 cm.
between the floor and the end of the duct.
• Do not bend the duct too sharply when
positioning it.
This can impede proper hot-air expulsion, which
may reduce cooling efficiency.
Dehumidification
When set to , the appliance removes humidity
from the atmosphere. It does not, however, control
the temperature.
❏
Turn drainage stopcock 90° in an anti-clockwise
direction.
❏
Remove stopcock plug and insert drainage pipe.
stored in the main filter compartment.
❏
Place a bowl at the drainage pipe outlet to collect
the condensed water in.
❏
Put the air extraction duct in storage position.
❏
Set control knob to dehumidification position ,
Fig. 8, by pressing the "mode" button.
❏
The amount of water removed from the air can
reach as much as 30 liters/24 hours, depending
on atmospheric conditions