Chapter 4
Technical Specifications
RUGGEDCOM RSG2300
Installation Guide
34
Operating Environment
ad
Operating temperature range of 0 to 70 °C (32 to 185 °F).
GBIC Gigabit Transceivers
NOTE
GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless specified
otherwise.
Mode
Connector
Type
Cable
Type (µm)
Tx λ
(nm)
ae
Tx
Minimum
(dBm)
af
Tx
Maximum
(dBm)
af
Rx
Sensitivity
(dBm)
af
Rx
Saturation
(dBm)
af
Maximum
Distance
(km)
ag
Power
Budget
(dB)
SM
SC
9/125
1310
-9.5
-3
-21
-3
10
11.5
SM
SC
9/125
1310
-7
-3
-24
-3
25
17
SM
ah
SC
9/125
1550
0
5
-23
-3
70
23
ae
Typical.
af
All optical power numbers are listed as dBm averages.
ag
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
ah
Operating temperature range of -25 to 85 °C (-13 to 185 °F).
Section 4.6
Operating Environment
Parameter
Range
Comments
Ambient Operating Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Temperature as measured from a 30 cm
radius surrounding the center of the enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage Temperature
-40 to 85 °C (-40 to 185 °F)
Section 4.7
Mechanical Specifications
Parameter
Value
Dimensions
Weight
5.2 kg (11.5 lbs)
Ingress Protection
IP40 (1 mm or 0.04 in objects)
Enclosure
18 AWG Galvanized Steel
Содержание RUGGEDCOM RSG2300
Страница 4: ...RUGGEDCOM RSG2300 Installation Guide iv ...
Страница 12: ...RUGGEDCOM RSG2300 Installation Guide Chapter 1 Introduction Description 4 ...
Страница 36: ...RUGGEDCOM RSG2300 Installation Guide Chapter 3 Communication Ports BNC Ports 28 ...