Chapter 2
Installing the Device
RUGGEDCOM RS969
Installation Guide
10
Unpacking the Device
1. Review the relevant certification information for any regulatory requirements. For more information, refer to
2. Mount the device.
3. Connect the failsafe alarm relay.
4. Connect power to the device and ground the device to safety Earth.
5. Connect the device to the network.
6. Configure the device.
Section 2.2
Unpacking the Device
When unpacking the device, do the following:
1. Inspect the package for damage before opening it.
2. Visually inspect each item in the package for any physical damage.
3. Verify all items are included.
IMPORTANT!
If any item is missing or damaged, contact Siemens for assistance.
Section 2.3
Mounting the Device
The RUGGEDCOM RS969 is designed to be mounted on a panel by affixing the top and bottom flanges of the
device to a panel using screws.
IMPORTANT!
Heat generated by the device is channeled outwards from the enclosure. As such, it is recommended
that 2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some
convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
NOTE
For detailed dimensions of the device with panel mount hardware installed, refer to
.
To mount the device to a panel, do the following:
1. Place the device against the panel and align the flanges with the mounting holes.
Содержание RUGGEDCOM RS969
Страница 4: ...RUGGEDCOM RS969 Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS969 Installation Guide x Customer Support ...
Страница 18: ...Chapter 1 Introduction RUGGEDCOM RS969 Installation Guide 8 Decommissioning and Disposal ...
Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS969 Installation Guide 30 Dimension Drawings ...
Страница 56: ...Chapter 7 Certification RUGGEDCOM RS969 Installation Guide 46 EMC and Environmental Type Tests ...