Chapter 1
Introduction
RUGGEDCOM RS969
Installation Guide
6
Supported Fiber Optic Cables
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
•
Section 1.4.1, “Supported Fiber Optic Cables”
Section 1.4.1
Supported Fiber Optic Cables
The following fiber optic cable types are supported under the stated conditions.
Distance (m)
Cable Type
Wavelength (nm)
Modal Bandwidth
(MHz·km)
100Base-FX
1000Base-SX
10GBase-SR
850
200
—
275
33
OM1 (62.5/125)
1300
500
2000
—
—
850
500
—
550
82
OM2 (50/125)
1300
500
2000
—
—
850
1500
—
550
300
OM3 (50/125)
a
1300
500
2000
—
—
850
3500
—
550
400
OM4 (50/125)
a
1300
500
2000
—
—
a
Laser optimized.
Section 1.5
Ingress Protection
IEC International Standard 60529 (Edition 2.1: 2001-02) is a "classification of degrees of protection provided
by enclosures as a system for specifying the enclosures of electrical equipment on the basis of the degree of
protection provided by the enclosure." These ratings are determined by specific tests.
The RUGGEDCOM RS969 Industrial Ethernet Switch is manufactured and tested to IP67 standards. With an IP67
rating a product will be "dust tight" and remain completely sealed when immersed in water to a depth of 1 meter
for 1 hour (IEC 60529).
These caps completely seal off unused ports on the IP67 Industrial Ethernet Switch. It has an IP67 rated seal that
keeps out all contaminants like dirt, oil, and water.
Содержание RUGGEDCOM RS969
Страница 4: ...RUGGEDCOM RS969 Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS969 Installation Guide x Customer Support ...
Страница 18: ...Chapter 1 Introduction RUGGEDCOM RS969 Installation Guide 8 Decommissioning and Disposal ...
Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS969 Installation Guide 30 Dimension Drawings ...
Страница 56: ...Chapter 7 Certification RUGGEDCOM RS969 Installation Guide 46 EMC and Environmental Type Tests ...