Chapter 2
Installing Device
RUGGEDCOM RS416
Installation Guide
12
Connecting DC Power
4
2
1
3
4
6
5
7
4
6
5
3
6
5
7
4
6
5
Figure 7: Terminal Block Wiring
1.
Screw-Type Terminal Block
2.
Pluggable Terminal Block
3.
Jumper
4.
Positive/Live (+/L) Terminal
5.
Negative/Neutral (-/N)
Terminal (-/N)
6.
Surge Ground Terminal
7.
Chassis Ground Terminal
4. Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
For more information, refer to
Section 2.2.3, “Wiring Examples”
5. Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to
the chassis ground terminal. The surge ground terminals are used as the ground conductor for all surge and
transient suppression circuitry internal to the unit.
6. Connect the ground terminal on the power source to the chassis ground terminal on the device. For more
information, refer to
Section 2.4, “Grounding the Device”
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make
sure the supplied terminal block cover is always installed before the device is powered.
7. Install the terminal block cover.
Section 2.2.2
Connecting DC Power
To connect a single high or low DC power supply to the device, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the
field, remove the metal jumper. This metal jumper connects transient suppression circuitry to chassis
ground and must be removed in order to avoid damage to transient suppression circuitry during
testing.
Содержание RUGGEDCOM RS416
Страница 4: ...RUGGEDCOM RS416 Installation Guide iv ...
Страница 34: ...RUGGEDCOM RS416 Installation Guide Chapter 3 Communication Ports Connecting Multiple RS485 Devices 26 ...
Страница 40: ...RUGGEDCOM RS416 Installation Guide Chapter 4 Technical Specifications Mechanical Specifications 32 ...
Страница 44: ...RUGGEDCOM RS416 Installation Guide Chapter 5 Dimension Drawings 36 ...
Страница 50: ...RUGGEDCOM RS416 Installation Guide Chapter 6 Certification EMC and Environmental Type Tests 42 ...