Certification
6.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
IEC 61000-4-11
100% for 5 Periods,
100% for 50 Periods
Signal Ports
2.5 kV Common, 1 kV
Differential Mode @ 1 MHz
3
DC Power Ports
2.5 kV Common, 1 kV
Differential Mode @ 1 MHz
3
IEC 61000-4-12
Damped
Oscillatory
AC Power Ports
2.5 kV Common, 1 kV
Differential Mode @ 1 MHz
3
Signal Ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-16
Mains
Frequency
Voltage
DC Power Ports 30 V Continuous, 300 V for 1 s
4
IEC 61000-4-17 Ripple on DC
Power Supply
DC Power Ports
10%
3
Signal Ports
2 kVAC (Fail-Safe Relay output)
DC Power Ports
1.5 kVDC
Dielectric
Strength
AC Power Ports
2 kVDC
Signal Ports
5 kV (Fail-Safe Relay Output)
DC Power Ports
5 kV
IEC 60255-5
HV Impulse
AC Power Ports
5 kV
EMC Immunity Type Tests per IEEE 1613
Note
The RS1600 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports. Class 1 allows for temporary communication loss,
while Class 2 requires error-free and interrupted communications.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 4 kV @ 2.5 kHz
DC Power Ports
± 4 kV
AC Power Ports
± 4 kV
Fast Transient
Earth Ground Ports
± 4 kV
Signal Ports
2.5 kV Common mode @ 1MHz
DC Power Ports
2.5 kV Common and Differential Mode @ 1MHz
Oscillatory
AC Power Ports
2.5 kV Common and Differential Mode @ 1MHz
Signal Ports
5 kV (Failsafe Relay)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Signal Ports
2 kVAC (Failsafe Relay)
Dielectric
Strength
DC Power Ports
1.5 kVDC
RUGGEDCOM RS1600
Installation Manual, 01/2021, C79000-G8976-1013-03
31