RUGGEDCOM ROX II
CLI User Guide
Chapter 5
System Administration
Viewing a List of Active Alarms
109
Alarm Type
Alarm
Description
Suggested Resolution
maximum operating temperature
range of the device.
Chassis
Module Type Mismatch
The configured module type does not
match the detected module type.
Updated the chassis configuration or
install the correct module type.
Chassis
Line Module Removed
The specified line module has either
been removed or lost contact with the
chassis.
Inspect the line module.
Chassis
Line Module Inserted
A new line module has been inserted
in the specified slot.
Security
Firmware Integrity Check Failed
The firmware has failed the binary
integrity check, indicating that one
or more operating system files have
been modified or tampered with.
Contact Siemens Customer Support.
Section 5.7.2
Viewing a List of Active Alarms
To view a list of alarms for a specific alarm type, type:
show
admin alarms
A table or list similar to the following example appears:
ruggedcom# show admin alarms | tab
ALARM EVENT
SUBSYSTEM ID ID SEVERITY DESCRIPTION DATE TIME USER ACTIONS
ACTUATORS
---------------------------------------------------------------------------------------------
switch 1 1 notice Link-up on port lm1/8 Wed Feb 6 16:08:44 2013 clear-or-ack none
For information on how to clear or acknowledge an active alarm, refer to
Section 5.7.3
Clearing and Acknowledging Alarms
There are two types of alarms: conditional and non-conditional. Conditional alarms are generated when the
condition is true and cleared when the condition is resolved and the incident is acknowledged by the user.
Non-conditional alarms, however, are simply generated when the event occurs (a notification) and it is the
responsibility of the user to clear the alarm.
An example of a conditional alarm is a
link down
alarm. When the condition is resolved (i.e. the link comes up),
the LED and alarm relay are both disabled, if the
auto-clear
option is enabled.
Examples of non-conditional alarms are
link up
and internal configuration errors.
CONTENTS
•
Section 5.7.3.1, “Clearing Alarms”
•
Содержание RUGGEDCOM ROX II
Страница 2: ...RUGGEDCOM ROX II CLI User Guide ii ...
Страница 4: ...RUGGEDCOM ROX II CLI User Guide iv ...
Страница 39: ...RUGGEDCOM ROX II CLI User Guide Table of Contents xxxix 19 5 VLANs 752 ...
Страница 40: ...Table of Contents RUGGEDCOM ROX II CLI User Guide xl ...
Страница 46: ...Preface RUGGEDCOM ROX II CLI User Guide xlvi Customer Support ...
Страница 96: ...Chapter 2 Using RUGGEDCOM ROX II RUGGEDCOM ROX II CLI User Guide 50 Accessing Maintenance Mode ...
Страница 170: ...Chapter 5 System Administration RUGGEDCOM ROX II CLI User Guide 124 Deleting a Scheduled Job ...
Страница 256: ...Chapter 6 Security RUGGEDCOM ROX II CLI User Guide 210 Enabling Disabling a Firewall ...
Страница 402: ...Chapter 11 Wireless RUGGEDCOM ROX II CLI User Guide 356 Managing Cellular Modem Profiles ...
Страница 646: ...Chapter 13 Unicast and Multicast Routing RUGGEDCOM ROX II CLI User Guide 600 Deleting a Multicast Group Prefix ...
Страница 732: ...Chapter 15 Network Discovery and Management RUGGEDCOM ROX II CLI User Guide 686 Viewing NETCONF Statistics ...
Страница 790: ...Chapter 17 Time Services RUGGEDCOM ROX II CLI User Guide 744 Deleting a Broadcast Multicast Address ...