background image

CE1B2225E / 27.01.1999

Subject to alteration

Siemens Building Technologies / Landis & Staefa Division

Do you want to change the temperature level
or will you be absent for a short period of
time?

When pressing this button, you change from
the current temperature level to the other. The
display shows either 

, when the change

was made from the economy temperature, or

, when it was made from the normal

temperature. This means you can select the
economy temperature during the time you are
absent. These changes are valid only up to
the next switching point.

Do you want to enter your own temperatures
and heating periods?

The controller has two different switching patterns A and
B which can be assigned to the respective weekday
block 1-5 / weekend block 6-7 (= Auto A/B), or the 24-
hour settings A and B.
Proceed as follows:

A1

Use the setting slider to select the required
switching position (e.g. A1) and press

 to enter the required switching

time. 

All other switching positions (A2…A6

and B1…B2) are set the same way.

Select «Normal temperature» and press

 to set the required value.

Select «Economy temperature» and press

 to set the required value.

Auto

Run

Move the setting slider back to this position
and close the cover.

Table for entering selected values

Enter the values set by you in the following table. The
numbers already contained in the table represent
factory settings.

Temp.

6.00

8.00

11.00 13.00 17.00 22.00

Switching times

A1

A2

A3

A4

A5

A6

B1

B2

7.00

23.00 20° C 16° C

22

25

Z

1

2

E

Will you go on holiday?

You can enter the duration of your holiday period. In
that case, the controller immediately switches to
economy mode and back to the selected operating
mode when the holiday period has expired. During the
holiday period, the display shows 

 and the number of

days left.
Proceed as follows:

Move the setting slider to the holiday symbol
and press 

 to enter the duration of

the holiday period (99 days max.).

Auto

Run

Move the setting slider back to this position
and close the cover. 

If you return from your

holidays earlier than expected, reset the
holiday period to 

.

Do you need to change the time of day or the
weekday?

Move the setting slider to the time of day
position and press 

 to set the

required time of day.

Day

Move the setting slider to the weekday
position and press 

 to select the

new weekday (1 = Monday…7 = Sunday).

Auto

Run

Move the setting slider back to this position
and close the cover.

Do you wish to return to the factory settings?

°C

By pressing these three buttons
simultaneously, a complete reset is made,
which means that the switching times and
temperatures will be reset to their default
values. Caution: All individual settings will
be lost!
 At the same time, a display check is
made, which looks as follows:

1

2

3

4

5

6

7

0

6

12

18

24

A B

22

25

Z

1

3

Does the 

 symbol appear in the display?

If this symbol appears, you need to replace the batteries
within the next three months.

Do you want to change the batteries?

• 

Get two new alcaline batteries type AA, 1.5 V.

• 

Remove the battery holder, then the batteries, insert
the new batteries and replace the battery holder.
Caution: The setting data are maintained for a
maximum of one minute only!

• 

Make certain the old batteries are disposed of
properly, in compliance with environmental
requirements.

Energy saving tips without sacrificing comfort

• 

Never allow room temperatures to exceed 21 °C.

• 

Press 

 to change to economy temperature,

even if you are absent for short periods of time only.

• 

Air out the rooms for short periods of time only, but
properly, with the windows wide open.

Auxiliary functions

Your room temperature controller provides a number of
auxiliary functions, but these should only be set by your
heating engineer.

Отзывы: