Siemens Building Technologies 

Room temperature controllers 

CE1N3035en 

HVAC Products 

 

25.09.2003 

Technical data 

Operating voltage 

• 

RDE10 at L and N 

AC 230 V +10/-15 % 

• 

RDE10.1 

DC 3 V (2 x 1.5 V AAA Alkaline - batteries) 

Frequency (RDE10) 

50 or 60 Hz 

Power consumption (RDE10) 

4VA 

Battery life (RDE10.1) 

> 1 years (AAA Alkaline - batteries) 

Control output Q12 (N.C. contact) 

 

Rating RDE10    (AC 230 V) 

max. 5 A 

Rating RDE10.1 (AC 24…250 V) 

max. 5(2) A 

Control output Q14 (N.O. contact) 

 

Rating RDE10    (AC 230 V) 

max. 5 A 

Rating RDE10.1 (AC 24…250 V) 

max. 5(2) A 

Switching differential SD 

1 K 

Setpoint setting range 

5…35 °C (normal operation) 

 

 

0 (OFF) and 5…35 °C (energy saving mode) 

Factory setting normal operation 

20 °C 

Factory setting energy saving mode  8 °C 

Resolution of settings and displays 

 

Setpoints 0.5 

°C 

Switching times 

60 min  

Actual value displays 

0.5 °C 

Time of day displays 

1 min 

 

Operation to 

IEC 

721-3-3 

Climatic conditions 

class 3K5 

Temperature 0…+50 

°C 

Humidity 

<95 % r. h. 

Transport to 

IEC 

721-3-2 

Climatic conditions 

class 2K3 

Temperature -25…+60 

°C 

Humidity 

<95 % r. h. 

Mechanical conditions 

class 2M2 

Storage to 

IEC 

721-3-1 

Climatic conditions 

class 1K3 

Temperature -25…+60 

°C 

Humidity 

<95 % r. h. 

 conformity to 

EMC directive 

89/336/EEC 

Low voltage directive 

73/23/EEC and 93/68/EEC 

N474

 

C-Tick

 conformity to 

EMC emission standard 

 

AS/NSZ 4251.1:1994 

Product standards 

Automatic electrical controls for 

EN 60 730 – 1 and 

household and similar use 

EN 60 730 – 2 - 9 

Electromagnetic compatibility 

Emissions 

EN 50 081-1 

Immunity 

EN 50 082-1 

Safety class 

II to EN 60730 

Pollution class 

normal 

Degree of protection of housing 

IP30 to EN 60529 

Power supply 

Control outputs 

Functional data 

Environmental conditions 

Norms and standards 

Содержание RDE10 Series

Страница 1: ...Operating modes normal operation and energy saving mode 7 day time switch and manual operation Mains powered AC 230 V RDE10 or battery powered DC 3 V RDE10 1 Use The RDE10 is used for the control of the room temperature in heating systems Typical applications Apartments Commercial spaces Schools For the control of the following pieces of equipment Thermic valves or zone valves Gas or oil burners F...

Страница 2: ...he set point can be readjusted by pressing buttons and In energy saving mode the unit can also be switched to Off This is accomplished by selecting a setpoint of 5 C and then keeping button depressed for 4 seconds In that case symbol does not appear The changeover between the operating modes can take place either automatically or manually depending on the position of the operating mode selector Wh...

Страница 3: ...ation required for operating mode changeover are retained for 3 minutes This is enough to cope with power fail ures of short duration with RDE10 or when changing the batteries with RDE10 1 Type summary Type reference Features RDE10 Mains powered AC 230 V RDE10 1 Battery powered DC 3 V Ordering When ordering please give name and type references e g room temperature con troller RDE10 Valve actuators...

Страница 4: ... 4 Current switching pattern with flashing time pointer 5 symbol when actual room temperature is displayed 6 Normal operation Energy saving mode 7 symbol in automatic mode or when selecting the switching pattern 8 heating on 9 symbol indicating that batteries need to be replaced only with battery powered versions 10 Buttons for adjusting the setpoints the time of day and the switching times 11 Ope...

Страница 5: ...nce with local regulations If there are thermostatic radiator valves in the reference room they must be set to their fully open position The controller is maintenance free If the temperature on the display does not agree with the room temperature effectively measured the temperature sensor can be recalibrated For that purpose both buttons and must be pressed simultaneously for 3 seconds Then the t...

Страница 6: ...and displays Setpoints 0 5 C Switching times 60 min Actual value displays 0 5 C Time of day displays 1 min Operation to IEC 721 3 3 Climatic conditions class 3K5 Temperature 0 50 C Humidity 95 r h Transport to IEC 721 3 2 Climatic conditions class 2K3 Temperature 25 60 C Humidity 95 r h Mechanical conditions class 2M2 Storage to IEC 721 3 1 Climatic conditions class 1K3 Temperature 25 60 C Humidit...

Страница 7: ...1 Q12 N L L N Ln Lx Nx Y1 3031A02 N1 Q14 Q11 3V Q12 RDE10 RDE10 1 N1 Room temperature controller Y1 Regulating unit L Ln Live AC 230 V N Neutral AC 230 V Lx Live AC 24 250 V Q11 Q12 N C contact for N O valves Q11 Q14 N O contact for N C valves Nx Neutral AC 24 250 V Application examples T T F1 F2 N1 M1 Y2 2222S01 T T F1 F2 N1 M1 Y2 2222S02 T T Room temperature controller with direct control of a g...

Страница 8: ...cuit pump precontrol by manual mixing valve F1 Thermal reset limit thermostat F2 Safety limit thermostat M1 Circulating pump N1 RDE10 room temperatures controller Y1 3 port valve with manual adjustment Y2 Magnetic valve Dimensions 96 119 23 8 3035M01 89 45 4 3035M02 28 28 28 28 26 30 35 30 11 8 112 3 4 Controller Baseplate 2003 Siemens Building Technologies AG Subject to alteration ...

Отзывы: