RDD100.1DHW   Room thermostat with independent DHW control 

CB1N1421en_01 

Building Technologies 

 

2013-03-14 

 Continuous-flow water heater 

  Small water heating systems 

 
 

Functions  

  Room temperature control via built-in temperature sensor 

  Selection of operating mode with operating mode touchkey 

  Display of current room temperature or setpoint in 

°

C or 

°

 Touchkey lock (manually) 

 Setpoint lock 

  Reloading factory settings for commissioning and control parameters 

 Independent DHW 

 
 

Temperature control 

The unit acquires the room temperature with its built-in sensor and maintains the 
setpoint by delivering control commands. The switching differential is 1 K. 

Q14

T[°C]

ON

OFF

W

SD

1421D

01

 

 

T Room 

temperature 

SD Switching 

differential 

Room temperature setpoint 

Q14 

Output signal for heating 

 
 

Type summary 

Product No. 

Stock No. 

Features 

RDD100.1DHW

S55770-T277 

DHW room thermostat 

Battery-powered DC 3 V 

 
 

Ordering 

  When ordering, please indicate product No./stock No. and description 

 Example: 

  Valve actuators must be ordered separately 

 
 
 
 
 
 
 
 

Product No.

 

Stock No.

 

Description

 

RDD100.1DHW 

S55770-T277 

DHW room thermostat 

Содержание RDD100.1 DHW

Страница 1: ... Off control of DHW Comfort Economy and Protection mode Adjustable commissioning and control parameters Battery powered DC 3 V 2 x 1 5 V AAA Use The RDD100 1DHW is used to control the room temperature in heating systems with independent control of DHW Typical applications Apartments For the control of the following plant components and of DHW Thermal valves or zone valves Gas or oil boilers Fans P...

Страница 2: ...ol parameters Independent DHW Temperature control The unit acquires the room temperature with its built in sensor and maintains the setpoint by delivering control commands The switching differential is 1 K Q14 T C ON OFF W SD 1421D01 T Room temperature SD Switching differential W Room temperature setpoint Q14 Output signal for heating Type summary Product No Stock No Features RDD100 1DHW S55770 T2...

Страница 3: ...h screw terminals The housing engages in the mounting plate and is secured with a screw 1 Operating mode touchkey 2 Touchkey for increasing a value 3 Touchkey for decreasing a value 4 DHW switch On Off touchkey Description Product No Data Sheet Electromotoric actuator SFA21 4863 Electrothermal actuator for radiator valves STA23 4884 Electrothermal actuator for small valves 2 5 mm STP23 4884 Damper...

Страница 4: ...ption 1 Indicating that batteries need to be replaced 6 F Room temperature in degrees Fahrenheit 2 Protection mode protection mode symbol can be enabled via parameter settings 7 Touchkey lock activated 3 Comfort mode 8 C Room temperature in degrees Celsius 4 Economy mode 9 Heating On 5 Display of room temperature setpoint etc 10 DHW On 11 Current room temperature Display ...

Страница 5: ...h all LCD segments flash indicating that reset was made correctly After the reset the ther mostat is ready for commissioning by qualified HVAC personnel The control parameters of the thermostat can be set to ensure optimum perform ance of the entire system Please refer to Operating Instructions CB1B1421 sec tion Do you want to change parameters If the temperature on the display does not agree with...

Страница 6: ...erature falls below 5 ºC the unit automatically activates the heating out put The symbol appears only if the icon is enabled via parameter settings When this DHW function is activated symbol appears on LCD Maintenance notes The thermostats are maintenance free Disposal In terms of disposal the room thermostats are classified as electronic scrap con forming to the European Directive 2011 65 EU WEEE...

Страница 7: ...ity As per IEC 60721 3 3 Class 3K5 0 50 C 95 r h Transport Climatic conditions Temperature Humidity Mechanical conditions As per IEC 60721 3 2 Class 2K3 25 60 C 95 r h Class 2M2 Storage Climatic conditions Temperature Humidity As per IEC 60721 3 1 Class 1K3 25 60 C 95 r h conformity to EMC directive Low voltage directive 2004 108 EC 2006 95 EC C Tick conformity to EMC emission standard AS NSZ 4251...

Страница 8: ... N1 M1 Y2 1421S02 T T DHW Room thermostat with direct control of a gas fired wall hung boiler with inde pendent control of DHW Room thermostat with direct control of a gas fired floor standing boiler with in dependent control of DHW T N1 Y1 1421S03 M1 DHW F1 Thermal reset limit thermostat F2 Safety limit thermostat M1 Circulating pump N1 RDD100 1DHW room thermostat Y1 Mixing 3 port valve with manu...

Страница 9: ...127 21 5 83 5 4 1 7 1 0 5 Ø80 Ø60 1421M01 Remarks Heating Because of the unavoidable self heating effects of the electrical current any loads of more than 3 Amperes connected to the unit can influence the control behavior and temperature accuracy in a negative way All dimensions in mm 2013 Siemens Switzerland Ltd Subject to change ...

Отзывы: